Palladium film decoupler for amperometric detection in electrophoresis chips

被引:80
作者
Chen, DC
Hsu, FL
Zhan, DZ
Chen, CH [1 ]
机构
[1] Natl Sun Yat Sen Univ, Dept Chem, Kaohsiung 80424, Taiwan
[2] Natl Tsing Hua Univ, Dept Chem, Hsinchu 300, Taiwan
关键词
D O I
10.1021/ac000452u
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Demonstrated in this article is that a palladium metal film can be applied to decouple the electric circuitry of electrochemical detection from that of the electrophoretic separation in an electrophoresis chip. The Pd solid-state field decoupler, as well as the working electrodes, is thermally evaporated onto the plastic chip and oriented vertically across the separation channel. After the sample zones flow over the Pd decoupler, their electrochemical response is measured at working electrodes in the downstream pathway. Because the electrodes are on the separation channel, the electrode channel alignment is no longer a problem. For a separation channel of roughly 200 mum in width and 75 mum in depth in 10 mM phosphate (pH 5.1), the noise level at the working electrode is < 15 pA at an electric field of 570 V/cm.
引用
收藏
页码:758 / 762
页数:5
相关论文
共 40 条
  • [1] An integrated nanoliter DNA analysis device
    Burns, MA
    Johnson, BN
    Brahmasandra, SN
    Handique, K
    Webster, JR
    Krishnan, M
    Sammarco, TS
    Man, PM
    Jones, D
    Heldsinger, D
    Mastrangelo, CH
    Burke, DT
    [J]. SCIENCE, 1998, 282 (5388) : 484 - 487
  • [2] Integration of separation capillary with a Au film electrode and an etched decoupler in amperometric capillary electrophoresis
    Chen, DC
    Hsieh, RMR
    Chen, CH
    [J]. JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 1998, 45 (02) : 257 - 262
  • [3] Parallel-opposed dual-electrode detector with recycling amperometric enhancement for capillary electrophoresis
    Chen, DC
    Chang, SS
    Chen, CH
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (15) : 3200 - 3205
  • [4] Chen YH, 1999, CLIN CHEM, V45, P1938
  • [5] GLASS CHIPS FOR HIGH-SPEED CAPILLARY ELECTROPHORESIS SEPARATIONS WITH SUBMICROMETER PLATE HEIGHTS
    EFFENHAUSER, CS
    MANZ, A
    WIDMER, HM
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (19) : 2637 - 2642
  • [6] Square-wave voltammetry detection for capillary electrophoresis
    Gerhardt, GC
    Cassidy, RM
    Baranski, AS
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (10) : 2167 - 2173
  • [7] CAPILLARY ELECTROPHORESIS AND SAMPLE INJECTION SYSTEMS INTEGRATED ON A PLANAR GLASS CHIP
    HARRISON, DJ
    MANZ, A
    FAN, ZH
    LUDI, H
    WIDMER, HM
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (17) : 1926 - 1932
  • [8] Ceramic microchips for capillary electrophoresis-electrochemistry
    Henry, CS
    Zhong, M
    Lunte, SM
    Kim, M
    Bau, H
    Santiago, JJ
    [J]. ANALYTICAL COMMUNICATIONS, 1999, 36 (08): : 305 - 307
  • [9] ONLINE COUPLING OF IN-VIVO MICRODIALYSIS SAMPLING WITH CAPILLARY ELECTROPHORESIS
    HOGAN, BL
    LUNTE, SM
    STOBAUGH, JF
    LUNTE, CE
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (05) : 596 - 602
  • [10] Postcolumn reaction detection with dual-electrode capillary electrophoresis-electrochemistry and electrogenerated bromine
    Holland, LA
    Lunte, SM
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (02) : 407 - 412