Noniterative complex permittivity retrieval using calibration-independent waveguide measurements

被引:8
作者
Hasar, Ugur Cem [1 ,2 ]
Kaya, Yunus [3 ]
机构
[1] Gaziantep Univ, Dept Elect & Elect Engn, TR-27310 Gaziantep, Turkey
[2] Ataturk Univ, Ctr Res & Applicat Nanosci & Nanoengn, TR-25240 Erzurum, Turkey
[3] Bayburt Univ, Dept Elect & Energy, TR-69000 Bayburt, Turkey
关键词
Calibration-independent; Explicit determination; Sample shifting; Complex permittivity; Waveguide measurements; REFERENCE-PLANE INVARIANT; TRANSMISSION-REFLECTION METHOD; BROAD-BAND MEASUREMENTS; CONSTITUTIVE PARAMETERS; FREE-SPACE; DIELECTRIC-CONSTANT; ELECTROMAGNETIC PARAMETERS; RESONANT-CAVITY; PERMEABILITY; COPLANAR;
D O I
10.1016/j.sna.2017.07.018
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Calibration-independent nonresonant measurements can be employed to eliminate the need for calibration before microwave measurements. These methods generally assume that the location of the sample in its measurement cell is known after the sample is positioned or shifted within the cell and that the length of the measurement cell is known. In addition, in general these methods necessitate some sort of numerical analysis to retrieve the complex permittivity of the sample. In this research paper, we propose a calibration-independent nonresonant waveguide method to first eliminate measurement errors arising from inaccurate knowledge of the location of the sample within its cell (after shifting) and arising from improper knowledge of the length of the measurement cell and second to determine the complex permittivity explicitly. In addition, our proposed method needs scattering parameter measurements from three different measurement configurations another improvement with respect to a similar calibration independent method requiring measurements from four different configurations. Furthermore, it does not necessitate that the sample be flushed to the measurement cell. We analyzed repeatability of cell connection and investigated uncertainty in the measurement of complex permittivity for a change in length of the sample and the cell and when air gap present between sample surfaces and guide walls. We validated the proposed method by measuring the complex permittivity of polyethylene sample and distilled water at X-band (8.2-12.4GHz). (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:654 / 666
页数:13
相关论文
共 50 条
  • [21] Analysis of Errors in Permittivity Measurements Using the Waveguide-Penetration Method
    Kik, Alfred
    Nishikata, Atsuhiro
    IEICE TRANSACTIONS ON COMMUNICATIONS, 2010, E93B (07) : 1697 - 1706
  • [22] Effective Constitutive Parameters Retrieval Method for Bianisotropic Metamaterials Using Waveguide Measurements
    Hasar, Ugur Cem
    Muratoglu, Abdurrahim
    Bute, Musa
    Barroso, Joaquim Jose
    Ertugrul, Mehmet
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2017, 65 (05) : 1488 - 1497
  • [23] Biaxial Permittivity Determination for Electrically Small Material Specimens of Complex Shape Using Shorted Rectangular Waveguide Measurements
    Scott, Mark M.
    Faircloth, Daniel L.
    Bean, Jeffrey A.
    Holliday, Samuel G.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2014, 63 (04) : 896 - 903
  • [24] Nano ferrites microwave complex permeability and permittivity measurements by T/R technique in waveguide
    Al-Moayed, Nawaf N.
    Afsar, Mohammed N.
    Khan, Usman A.
    McCooey, Sean
    Obol, Mahmut
    IEEE TRANSACTIONS ON MAGNETICS, 2008, 44 (07) : 1768 - 1772
  • [25] Estimation of complex permittivity using rectangular waveguide with flange by FDTD method
    Shibata, K
    Hashimoto, O
    Wada, K
    IEICE TRANSACTIONS ON ELECTRONICS, 2001, E84C (07) : 977 - 980
  • [26] Complex permittivity and permeability measurement at elevated temperatures using rectangular waveguide
    Wolfson, BJ
    Wentworth, SM
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2003, 38 (06) : 449 - 453
  • [27] A measurement of complex permittivity of lossy dielectrics by using flanged rectangular waveguide
    Hirano, M
    Takahashi, M
    Abe, M
    ELECTRONICS AND COMMUNICATIONS IN JAPAN PART II-ELECTRONICS, 2001, 84 (04): : 59 - 67
  • [28] Permeability Measurement of Metamaterials with Split-Ring-Resonators Using Free-Space Calibration-Independent Methods
    Hasar, Ugur C.
    Barroso, Joaquim J.
    JOURNAL OF INFRARED MILLIMETER AND TERAHERTZ WAVES, 2012, 33 (02) : 218 - 227
  • [29] Broad-band measurements of dielectric permittivity in coaxial line using partially filled circular waveguide
    Svirskas, Sarunas
    Jablonskas, Dziugas
    Rudys, Saulius
    Lapinskas, Saulius
    Grigalaitis, Robertas
    Banys, Juras
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (03)
  • [30] Extraction of Complex Permittivity and Complex Permeability of Liquids by Using a Grounded Coplanar Waveguide with Upper Shielding
    Yang, Yutao
    Yuan, Haoyun
    Si, Liming
    Crupi, Giovanni
    Wang, Li
    Gugliandolo, Giovanni
    Donato, Nicola
    Sun, Houjun
    Bao, Xiue
    2024 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS, MEMEA 2024, 2024,