Detection of Blood Glucose With Hemoglobin Content Using Compact Photonic Crystal Fiber

被引:29
|
作者
Vijayalakshmi, Dhinakaran [1 ]
Manimegalai, C. T. [1 ]
Ayyanar, N. [2 ,3 ]
Vigneswaran, D. [4 ]
Kalimuthu, K. [1 ]
机构
[1] SRM Inst Sci & Technol, Dept Elect & Commun Engn, Chennai 603203, Tamil Nadu, India
[2] Ton Duc Thang Univ, Inst Comp Sci, Div Comp Phys, Ho Chi Minh City, Vietnam
[3] Ton Duc Thang Univ, Fac Elect & Elect Engn, Ho Chi Minh City, Vietnam
[4] Univ Engn Ramanathapuram, Dept Phys, Ramanathapuram, Tamil Nadu 623513, India
关键词
Glucose; Sensitivity; Blood; Optical fiber sensors; Couplings; Glucose sensors; Indexes; Photonic crystal fiber; glucose sensor; hemoglobin; sensitivity; finite element method; couple mode theory; SURFACE-PLASMON RESONANCE; SENSOR; BIOSENSOR;
D O I
10.1109/TNB.2021.3097343
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We have proposed Twin Elliptical Core Photonic Crystal Fiber (TEC-PCF) sensor for the detection of blood glucose level under the influence of hemoglobin components. The main featuring of the proposed biosensor is to detect the wide range of blood glucose content with enhanced sensitivity, by utilizing small length of the fiber. In order to achieve this, we have constructed asymmetric TEC-PCF where the elliptical core is filled by blood sample. The numerical sensing characteristics are evaluated using Finite Element Method (FEM). By varying hemoglobin concentrations as 120 g/L, 140 g/L and 160 g/L, we realize enhanced blood glucose sensing with detection range from 0 g/L to 100 g/L. The sensing performance of the proposed biosensor is studied through the coupling length and transmission power spectrum by calculation of effective index of the coupling mode. The obtained maximum wavelength sensitivity under the influence of 160 g/L hemoglobin content is 2.4 nm/(g/L) and 2.42 nm/(g/L) with fiber length of 0.245 mm and 0.215 mm for X and Y polarization, respectively. Further, limit of detection (LOD) is calculated under the influence of 160 g/L hemoglobin content is 0.375 mg/L and 0.372 mg/L for X and Y polarization, respectively. The proposed miniaturized sensing device can be integrated with microfluidic systems for the development of next-generation biosensor applications as point of- care and lab-on-a-chip.
引用
收藏
页码:436 / 443
页数:8
相关论文
共 50 条
  • [1] Detecting hemoglobin content blood glucose using surface plasmon resonance in D-shaped photonic crystal fiber
    Lidiya, A. Esther
    Raja, R. Vasantha Jayakantha
    Van Dai Pham
    Quang Minh Ngo
    Vigneswaran, D.
    OPTICAL FIBER TECHNOLOGY, 2019, 50 : 132 - 138
  • [2] Detection of Glucose Content in Tears using Photonic Crystal based Surface Plasmon Resonance
    Sane, Vani
    Pati, Harshada
    Sriram, G.
    Sharan, Preeta
    2015 GLOBAL CONFERENCE ON COMMUNICATION TECHNOLOGIES (GCCT), 2015, : 720 - 724
  • [3] Highly sensitive photonic crystal fiber sensor for detection of hemoglobin and sucrose concentration
    Monazah, Seyede Mahboobeh Mousavi
    Salehi, Mohammad Reza
    PHYSICA SCRIPTA, 2024, 99 (12)
  • [4] Numerical Analysis of Photonic Crystal Fiber-Based Biosensor for Glucose Level Detection in Urine and Blood
    Haque, Emranul
    Noman, Abdullah Al
    Mithu, Asif Mohammad
    Ahmed, Feroz
    IEEE SENSORS JOURNAL, 2024, 24 (10) : 16010 - 16018
  • [5] D-glucose sensor using photonic crystal fiber
    Thenmozhi, Harikesavan
    Rajan, MuruganSenthil Mani
    Devika, Veluchamy
    Vigneswaran, Dhasarathan
    Ayyanar, Natesan
    OPTIK, 2017, 145 : 489 - 494
  • [6] Refractive index sensor using dual core photonic crystal fiber - glucose detection applications
    Maheswaran, S.
    Kuppusamy, P. G.
    Ramesh, S. M.
    Sundararajan, T. V. P.
    Yupapin, P.
    RESULTS IN PHYSICS, 2018, 11 : 577 - 578
  • [7] Bi-core photonic crystal fiber for blood component detection
    Vijayalakshmi, Dhinakaran
    Manimegalai, C. T.
    Selvakumar, Praveena
    JOURNAL OF OPTICS-INDIA, 2023, 52 (01): : 42 - 49
  • [8] Bi-core photonic crystal fiber for blood component detection
    Dhinakaran Vijayalakshmi
    C. T. Manimegalai
    Praveena Selvakumar
    Journal of Optics, 2023, 52 : 42 - 49
  • [9] Determination of blood types using a chirped photonic crystal fiber
    Malinin, A. V.
    Zanishevskaja, A. A.
    Skibina, Yu S.
    Silokhin, I. Yu
    Tuchin, V. V.
    Dubrovskiy, V. A.
    Dolmashkin, A. A.
    DYNAMICS AND FLUCTUATIONS IN BIOMEDICAL PHOTONICS VIII, 2011, 7898
  • [10] Terahertz detection of toxic gas using a photonic crystal fiber
    Qin, Jianyuan
    Zhu, Bei
    Du, Yong
    Han, Zhanghua
    OPTICAL FIBER TECHNOLOGY, 2019, 52