Full-scale test of an old heritage multi-storey building undergoing energy retrofitting with focus on internal insulation and moisture

被引:65
作者
Harrestrup, M. [1 ]
Svendsen, S. [1 ]
机构
[1] Tech Univ Denmark DTU, Dept Civil Engn, Sect Bldg Energy, DK-2800 Lyngby, Denmark
关键词
Energy renovation; Heritage building; Internal insulation; Full scale measurements; Numerical simulations; Moisture safe solutions; MOLD GROWTH; TEMPERATURE; HUMIDITY;
D O I
10.1016/j.buildenv.2014.12.005
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The hypothesis investigated in this article is: it is possible to carry out moisture safe energy renovations in the old existing multi-storey buildings with heritage value and still save 50% of the building's energy consumption by use of existing technologies. A holistic energy renovation on an old multi-storey building with heritage value was carried out. Focus was given to energy-saving measures that would preserve the original architectural expression of the building, such as internal insulation. Comprehensive measurements were performed on the energy consumption before and after the renovation to document the obtained savings. Numerical simulations were validated with the measurements in order to explain the savings and to carry out parameter variations on the energy saving measures. Since internal insulation was applied the durability and robustness were investigated and measurements of the temperature and relative humidity were performed in the wooden beams-ends embedded in the masonry brick wall. A solution where the insulation was stopped 200 mm above the floor was investigated. This increased the heat flows through the wall compared to a fully insulated wall, and calculations showed that the difference in the space heating consumption was 3 kWh/m(2)/yr. The measurements showed the proposed solution should have no risk of moisture problems. The measured energy consumption was reduced with 47% whereas the theoretical reduction could be reduced with 39-61% depending on the room set-point temperature (20-24 degrees C). (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:123 / 133
页数:11
相关论文
共 30 条
[1]  
[Anonymous], 2011, DS418
[2]   The influence of the wind-blocking effect by a building on its wind-driven rain exposure [J].
Blocken, B ;
Carmeliet, J .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2006, 94 (02) :101-127
[3]  
Brandt E, 2005, MOULD BUILDINGS GROW
[4]  
Cappelen J., 1999, DMI Technical Report 99-13
[5]  
Danish Energy Agency, 2010, GREEN EN ROAD DAN EN
[6]  
Danish Ministry of Climate, 2010, EN BUILD VOR EN
[7]  
Engelmark J., 1983, KOBENHAVNS ETAGEBOLI
[8]  
European Commission, 2010, ROADM LOW CARB EC 20
[9]   Impacts of airflows, internal heat and moisture gains on accuracy of modeling energy consumption and indoor parameters in passive building [J].
Firlag, Szymon ;
Zawada, Bernard .
ENERGY AND BUILDINGS, 2013, 64 :372-383
[10]  
Funch M, 2013, ENERGY REFURBISHMENT