The use of muscle flaps to treat left ventricular assist device infections

被引:22
作者
Hutchinson, OZ
Oz, MC
Ascherman, JA
机构
[1] Columbia Presbyterian Med Ctr, Dept Surg, Div Plast Surg, New York, NY 10032 USA
[2] Columbia Presbyterian Med Ctr, Dept Surg, Div Cardiothorac Surg, New York, NY 10032 USA
关键词
D O I
10.1097/00006534-200102000-00011
中图分类号
R61 [外科手术学];
学科分类号
摘要
Left ventricular assist devices have become an important adjunct in the therapeutic armamentarium for patients with end-stage heart failure. Although they may provide a bridge to transplantation, they are prone to certain problems, expecially infection. Because these are life-sustaining devices, changing the device or simple explantation may be a risky, if not impossible, option. Therefore, we evaluated the effectiveness of a surgical alternative, namely, coverage of infected devices with muscle or myocutaneous flaps. Eighty-two consecutive patients who underwent the insertion of 88 left ventricular assist devices at our institution over a 6.5-year period were evaluated. Follow-up was provided for all patients and ranged from 1 to 7.5 years. The duration of ventricular support ranged from 0 to 434 days. All patients who demonstrated clinical evidence of infection were identified. Over all, 54 patients (66 percent) had infections locally at the device site, at distant sites, or systemically during support. Cultured organisms included gram-positive and -negative bacteria, fungi, and viruses. Of the 56 infections in these 54 patients, 21 (38 percent) were device-related, i.e., in the pocket created by the device, in the device itself, or from the driveline. Thus, 24 percent (21 of 88) of all ventricular support devices inserted demonstrated device infection during use. Therapeutic modalities used to combat device-related infection included both nonsurgical management with antibiotics alone and surgical procedures such as device change or relocation; device explant, and flap coverage. Eight of the 20 patients in whom the 21 device-related infections occurred underwent surgical intervention. Four of these eight patients underwent local flap coverage of their infected left ventricular assist devices. All foul patients also had evidence of systemic infection, or "device endocarditis." Coverage was successfully achieved in all cases with pedicled rectus abdominis flaps. There were no perioperative complications. Two patients later underwent successful transplantation; the other two died from causes unrelated to the flap. In conclusion, the treatment of infected left ventricular assist devices currently includes both nonsurgical and surgical alter-natives. Of the latter, muscle flaps should be considered a first-line intervention to assist in eradicating infection by providing well-vascularized tissue. Although there were no perioperative complications, the 50 percent mortality rate is consistent with that reported for patients with "device endocarditis." It may be that flap coverage of infected ventricular assist devices, if instituted at an earlier stage in the therapeutic process, could help prevent systemic infection in these patients and, therefore, improve their overall outcome.
引用
收藏
页码:364 / 373
页数:10
相关论文
共 32 条
[1]   THE MUSCLE FLAP IN THE TREATMENT OF CHRONIC LOWER-EXTREMITY OSTEOMYELITIS - RESULTS IN PATIENTS OVER 5 YEARS AFTER TREATMENT [J].
ANTHONY, JP ;
MATHES, SJ ;
ALPERT, BS .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1991, 88 (02) :311-318
[2]  
Argenziano Michael, 1996, Journal of Heart and Lung Transplantation, V15, pS73
[3]  
Ashton RC, 1996, J HEART LUNG TRANSPL, V15, P1151
[4]   A RELIABLE BRIDGE TO CARDIAC TRANSPLANTATION - THE TCI LEFT-VENTRICULAR ASSIST DEVICE [J].
BURTON, NA ;
LEFRAK, EA ;
MACMANUS, Q ;
HILL, A ;
MARINO, JA ;
SPEIR, AM ;
AKL, BF ;
ALBUS, RA ;
MASSIMIANO, PS .
ANNALS OF THORACIC SURGERY, 1993, 55 (06) :1425-1431
[5]  
CATANESE KA, 1996, 16 ANN M INT SOC HEA
[6]  
DIDISHEIM P, 1989, T AM SOC ART INT ORG, V35, P54
[7]  
FISCHER S, 1995, 33 ANN M INF DIS SOC
[8]   MULTICENTER CLINICAL-EVALUATION OF THE HEARTMATE 1000-IP LEFT-VENTRICULAR ASSIST DEVICE [J].
FRAZIER, OH ;
ROSE, EA ;
MACMANUS, Q ;
BURTON, NA ;
LEFRAK, EA ;
POIRIER, VL ;
DASSE, KA .
ANNALS OF THORACIC SURGERY, 1992, 53 (06) :1080-1090
[9]  
FRAZIER OH, 1992, J HEART LUNG TRANSPL, V11, P530
[10]  
Goldstein D J, 1995, ASAIO J, V41, P873, DOI 10.1097/00002480-199510000-00010