Analysis of Heart Rate Variability and Breath to Breath Interval in Frequency Domain

被引:0
作者
Sengthipphany, Tick [1 ]
Tretriluxana, Suradej [2 ]
Chitsakul, Kitiphol [2 ]
机构
[1] King Mongkuts Inst Technol Ladkrabang, Int Coll, Biomed Measurement & Computat Lab, Bangkok, Thailand
[2] King Mongkuts Inst Technol Ladkrabang, Fac Engn, Dept Elect Engn, Biomed Measurement & Computat Lab, Bangkok, Thailand
来源
2014 7TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON) | 2014年
关键词
Heart rate variability (HRV); Breath to breath interval; frequency domain;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Respiratory is known to be a confounding factor of Heart Rate Variability (HRV) analysis. This article introduces a Breath-to-Breath Interval (BBI) spectral computation to investigate the insight between respiration and the HRV. Six males and five female volunteers (age 20-25 years) underwent the Electrocardiogram (ECG) and respiratory chest movement recordings for 5 minutes while sitting in resting condition. Auto Regressive Moving Average (ARMA) model was employed to the R-wave to R-wave interval (RRI) and BBI signals for the spectral analysis. The results from all participants demonstrate that the peak amplitude in high frequency (0.15-0.40 Hz) band are higher than the ones in low frequency (0.04-0.15 Hz) band in both RRI and BBI frequency plots. It suggests that respiratory plays a major role in HRV oscillation. Our further study is to develop a mathematical model to explain this finding.
引用
收藏
页数:4
相关论文
共 15 条
[1]   POWER SPECTRUM ANALYSIS OF HEART-RATE FLUCTUATION - A QUANTITATIVE PROBE OF BEAT-TO-BEAT CARDIOVASCULAR CONTROL [J].
AKSELROD, S ;
GORDON, D ;
UBEL, FA ;
SHANNON, DC ;
BARGER, AC ;
COHEN, RJ .
SCIENCE, 1981, 213 (4504) :220-222
[2]  
Alkhoori TM, 2014, MID EAST CONF BIO, P346, DOI 10.1109/MECBME.2014.6783274
[3]  
[Anonymous], 1996, HEART RAT VAR STAND, P354
[4]  
Aysin B, 2006, 2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, P1726
[5]   Processing of ECG and Breathing Signals to Study the Correlation of Respiration Waveform Time Intervals with HF and LF Powers of Heart Rate Variability [J].
Barrera, E. ;
Fabian, M. A. ;
Ruiz, H. .
CERMA 2008: ELECTRONICS, ROBOTICS AND AUTOMOTIVE MECHANICS CONFERENCE, PROCEEDINGS, 2008, :592-597
[6]  
Choi Jongyoon, 2011, REMOVAL RESP INFLUEN, P2649
[7]  
Demchenko V., ANAL HEART RATE VARI
[8]  
Espiritu Santo A., 2010, RESP RATE EXTRACTION
[9]  
Fumihiko Y., 2004, CHEST, V125, P685
[10]   Can heart rate variability timing reflect the body stress? [J].
Golosarsky, Boris .
MEDICAL HYPOTHESES, 2006, 67 (06) :1467-1468