High-resolution MR imaging of the rat spinal cord in vivo in a wide-bore magnet at 17.6 Tesla

被引:25
作者
Behr, VC
Weber, T
Neuberger, T
Vroemen, M
Weidner, N
Bogdahn, U
Haase, A
Jakob, PM
Faber, C
机构
[1] Univ Wurzburg, Dept Phys, D-97074 Wurzburg, Germany
[2] Univ Regensburg, Dept Neurol, D-8400 Regensburg, Germany
关键词
D O I
10.1007/s10334-004-0057-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The objective was to demonstrate the feasibility and to evaluate the performance of high-resolution in vivo magnetic resonance (MR) imaging of the rat spinal cord in a 17.6-T vertical wide-bore magnet. A probehead consisting of a surface coil that offers enlarged sample volume suitable for rats up to a weight of 220 g was designed. ECG triggered and respiratory-gated gradient echo experiments were performed on a Bruker Avarice 750 wide-bore spectrometer for high-resolution imaging. With T-2* values between 5 and 20 ms, good image contrast could be obtained using short echo times, which also minimizes motion artifacts. Anatomy of healthy spinal cords and pathomorphological changes in traumatically injured rat spinal cord in vivo could be visualized with microscopic detail. It was demonstrated that imaging of the rat spinal cord in vivo using a vertical wide-bore high-magnetic-field system is feasible. The potential to obtain high-resolution images in short scan times renders high-field imaging a powerful diagnostic tool.
引用
收藏
页码:353 / 358
页数:6
相关论文
共 25 条
  • [1] ANDERSON SA, 2003, P INT SOC MAGN RES M, V11, P763
  • [2] In vivo diffusion-weighted magnetic resonance microscopy of rat spinal cord:: Effect of ischemia and intrathecal hyperbaric 5% lidocaine
    Benveniste, H
    Qui, H
    Hedlund, LW
    Hüttemeier, PC
    Steele, SM
    Johnson, GA
    [J]. REGIONAL ANESTHESIA AND PAIN MEDICINE, 1999, 24 (04) : 311 - 318
  • [3] Spinal cord neural anatomy in rats examined by in vivo magnetic resonance microscopy
    Benveniste, H
    Qui, H
    Hedlund, LW
    D'Ercole, F
    Johnson, GA
    [J]. REGIONAL ANESTHESIA AND PAIN MEDICINE, 1998, 23 (06) : 589 - 599
  • [4] In vivo assessment of blood-spinal cord barrier permeability: serial dynamic contrastenhanced MRI of spinal cord injury
    Bilgen, M
    Dogan, B
    Narayana, PA
    [J]. MAGNETIC RESONANCE IMAGING, 2002, 20 (04) : 337 - 341
  • [5] In vivo magnetic resonance microscopy of rat spinal cord at 7 T using implantable RF coils
    Bilgen, M
    Elshafiey, I
    Narayana, PA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (06) : 1250 - 1253
  • [6] Dynamic contrast-enhanced MRI of experimental spinal cord injury: In vivo serial studies
    Bilgen, M
    Abbe, R
    Narayana, PA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) : 614 - 622
  • [7] Nuclear magnetic resonance microimaging of mouse spinal cord in vivo
    Bonny, JM
    Gaviria, M
    Donnat, JP
    Jean, B
    Privat, A
    Renou, JP
    [J]. NEUROBIOLOGY OF DISEASE, 2004, 15 (03) : 474 - 482
  • [8] Chen CN, 1989, BIOMEDICAL MAGNETIC
  • [9] In vivo diffusion tensor imaging of rat spinal cord at 7 T
    Elshafiey, I
    Bilgen, M
    He, RJ
    Narayana, PA
    [J]. MAGNETIC RESONANCE IMAGING, 2002, 20 (03) : 243 - 247
  • [10] Fenyes DA, 1999, MAGNET RESON MED, V42, P300, DOI 10.1002/(SICI)1522-2594(199908)42:2<300::AID-MRM12>3.0.CO