共 40 条
The effects of trace metal impurities on Ga-68-radiolabelling with a tris(3-hydroxy-1,6-dimethylpyridin-4-one) (THP) chelator
被引:14
作者:
Cusnir, Ruslan
[1
,2
]
Cakebread, Andrew
[3
]
Cooper, Margaret S.
[1
]
Young, Jennifer D.
[1
]
Blower, Philip J.
[1
]
Ma, Michelle T.
[1
]
机构:
[1] Kings Coll London, St Thomas Hosp, Sch Biomed Engn & Imaging Sci, London SE1 7EH, England
[2] Paul Scherrer Inst, Lab Radiochem, CH-5232 Villigen, Switzerland
[3] Kings Coll London, Mass Spectrometry Facil, Franklin Wilkins Bldg,150 Stamford St, London SE1 9NH, England
来源:
基金:
英国惠康基金;
英国工程与自然科学研究理事会;
英国医学研究理事会;
瑞士国家科学基金会;
关键词:
GENERATOR-PRODUCED GA-68;
COMPLEXATION;
LIGANDS;
ACID;
RADIOPHARMACEUTICALS;
PEPTIDES;
FE(III);
AGENTS;
IONS;
D O I:
10.1039/c9ra07723e
中图分类号:
O6 [化学];
学科分类号:
0703 ;
摘要:
GMP-grade Ge-68/Ga-68 generators provide access to positron-emitting Ga-68, enabling preparation of Positron Emission Tomography (PET) tracers and PET imaging at sites that do not have access to cyclotron-produced radionuclides. Radiotracers based on tris(3-hydroxy-1,6-dimethylpyridin-4-one) (THP) chelators enable simple one-step preparations of Ga-68 PET radiopharmaceuticals from pre-fabricated kits without pre-processing of generator eluate or post-purification. However, trace metal impurities eluted along with Ga-68 could compete for THP and reduce radiochemical yields (RCY). We have quantified trace metal impurities in Ga-68 eluate from an Eckert & Ziegler (E&Z) generator using ICP-MS. The metals Al, Fe, Ga-nat, Pb, Ti and Zn-nat were present in generator eluate in significantly higher concentrations than in the starting eluent solution. Concentrations of Fe and Ga-nat in eluate were in the range of 0.01-0.1 mu M, Al, Zn and Pb in the range of 0.1-1 mu M, and Ti in the range of 0.9-1.5 mu M. To assess the ability of THP to chelate Ga-68 in the presence of such metal ions, radiolabelling reactions were undertaken in which selected metal ions were added to make them equimolar with THP, or higher. Al3+, Fe3+, Ga-nat(3+) and Ti4+ reduced RCY at concentrations equimolar with THP and higher, but at lower concentrations they did not affect RCY. Pb2+, Zn2+, Ni2+ and Cr3+ had no effect on RCY (even under conditions in which each metal ion was present in 100-fold molar excess over THP). The multi-sample ICP-MS analysis reported here is (to date) the most comprehensive and robust quantification of metal impurities in the widely used E&Z Ga-68 generator. Ga-68 from an E&Z generator enables near-quantitative radiolabelling of THP at chelator concentrations as low as 5 mu M (lower than other common gallium chelators) without pre-processing. The combination of Al3+, Fe3+, Ga-nat(3+) and Ti4+ in unprocessed Ga-68 eluate is likely to decrease RCY of Ga-68 radiolabelling if a lower amount of THP chelator is used, and future kit design should take this into account. To increase specific activities by using even lower THP concentrations, purification of Ga-68 from trace metal ions will likely be required.
引用
收藏
页码:37214 / 37221
页数:8
相关论文