Predictive power management strategies for stand-alone hydrogen systems: Operational impact

被引:47
作者
Brka, Adel [1 ]
Al-Abdeli, Yasir M. [1 ]
Kothapalli, Ganesh [1 ]
机构
[1] Edith Cowan Univ, Sch Engn, 270 Joondalup Dr, Joondalup, WA 6027, Australia
关键词
Hydrogen; Predictive; Power management strategy; Renewables; Device intermittency; Optimisation; RENEWABLE ENERGY-SYSTEMS; PARTICLE SWARM OPTIMIZATION; OPTIMAL-DESIGN; TECHNOECONOMIC OPTIMIZATION; PERFORMANCE ANALYSIS; GENERATION SYSTEM; HYBRID; STORAGE; MODEL; CONVERSION;
D O I
10.1016/j.ijhydene.2016.03.085
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This paper compares the operational impacts of both predictive and reactive Power Management Strategies (P-PMS and R-PMS). The study is implemented for a stand-alone hybrid system based on wind turbines (WG), batteries (BAT) and hydrogen technology. The P-PMS uses real-time Neural Network (NN) predictions of wind speed and load demand to adjust the control set points affecting the switching of devices. The study also analyses the effects of using another intelligent technique, Particle Swarm Optimisation (PSO), for real-time optimisation of fuel cell operation. Genetic Algorithms (GA) are used to optimally size the hydrogen system. The methods employed include MATLAB simulations to implement the three intelligent techniques (GA, NN and PSO) and integration of experimentally derived fuel cell characteristics as well as highly dynamic electric load and wind speed profiles. The research presented in this study is an extension of an earlier work in which the concept of P-PMS was experimentally validated and the effects of some software and hardware related controlling parameters assessed. This paper however goes further by analysing the impact of using P-PMS on the economic and operational characteristics of stand-alone hydrogen systems by benchmarking it against an R-PMS. Results reveal that a hybrid system operating under a P-PMS outperforms that with an R-PMS in terms of cost, renewables penetration and environmental footprint. In addition, this study showed that P-PMS can help mitigate the impact of the transient response of the backup components (fuel cell and electrolyser) on the system sizing and operation. However, these merits are realised only if a particularly high reliability of load satisfaction is required. Results also show that a P-PMS highly depends on the accuracy of the employed (NN) prediction tool. The proposed predictive strategies are proven to be better than other solutions that exist in literature in terms of reducing the cost. Copyright (C) 2016, Hydrogen Energy Publications, LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:6685 / 6698
页数:14
相关论文
共 71 条
[21]   Comparative evaluation of different power management strategies of a stand-alone PV/Wind/PEMFC hybrid power system [J].
Dursun, Erkan ;
Kilic, Osman .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2012, 34 (01) :81-89
[22]   Size optimization of a PV/wind hybrid energy conversion system with battery storage using simulated annealing [J].
Ekren, Orhan ;
Ekren, Banu Y. .
APPLIED ENERGY, 2010, 87 (02) :592-598
[23]   Real-time performance analysis of an optimally sized hybrid renewable energy conversion unit [J].
Erdinc, O. ;
Elma, O. ;
Uzunoglu, M. ;
Selamogullari, U. S. .
ENERGY AND BUILDINGS, 2014, 75 :419-429
[24]   Optimum design of hybrid renewable energy systems: Overview of different approaches [J].
Erdinc, O. ;
Uzunoglu, M. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2012, 16 (03) :1412-1425
[25]   The importance of detailed data utilization on the performance evaluation of a grid-independent hybrid renewable energy system [J].
Erdinc, O. ;
Uzunoglu, M. .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2011, 36 (20) :12664-12677
[26]   Energy management strategy based on receding horizon for a power hybrid system [J].
Feroldi, Diego ;
Rullo, Pablo ;
Zumoffen, David .
RENEWABLE ENERGY, 2015, 75 :550-559
[27]   Performance investigation of a hybrid renewable power generation and storage system using systemic power management models [J].
Giaouris, Damian ;
Papadopoulos, Athanasios I. ;
Ziogou, Chrysovalantou ;
Ipsakis, Dimitris ;
Voutetakis, Spyros ;
Papadopoulou, Simira ;
Seferlis, Panos ;
Stergiopoulos, Fotis ;
Elmasides, Costas .
ENERGY, 2013, 61 :621-635
[28]   Intelligent power management strategy of hybrid distributed generation system [J].
Hajizadeh, Amin ;
Golkar, Masould Aliakbar .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2007, 29 (10) :783-795
[29]  
Hearps P, 2013, RENEWABLE ENERGY TEC, P1
[30]   INTERMITTENT OPERATION AND OPERATION MODELING OF AN ALKALINE ELECTROLYZER [J].
HUG, W ;
BUSSMANN, H ;
BRINNER, A .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 1993, 18 (12) :973-977