Low voltage CTPA for patients with suspected pulmonary embolism

被引:21
|
作者
Zamboni, Giulia A. [1 ]
Guariglia, Stefania [2 ]
Bonfante, Alberto [1 ]
Martino, Cristian [1 ]
Cavedon, Carlo [2 ]
Mucelli, Roberto Pozzi [1 ]
机构
[1] Azienda Osped Univ Integrata Verona, Policlin GB Rossi, Ist Radiol, I-37134 Verona, Italy
[2] Azienda Osped Univ Integrata Verona, UO Fis Sanitaria, I-37126 Verona, Italy
关键词
Computed tomography; Pulmonary embolism; Technique; IMAGE QUALITY; ANGIOGRAPHY;
D O I
10.1016/j.ejrad.2011.06.051
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To test a low dose, low voltage protocol for the diagnosis of pulmonary embolism. Materials and methods: 50 Patients with clinically suspected pulmonary embolism underwent CTPA with 80 kVp and 295 mAs (test group) on a 64-row MDCT scanner. These patients were compared to a similar group of 50 patients scanned on the same scanner with the 120 kVp protocol with automatic tube current modulation (control group). All patients received 100-110 ml of a 370 mgI/ml solution at 4.5 cm(3)/s. Scans were compared for quantitative imaging parameters (attenuation and standard deviation in the main, right and left pulmonary arteries, in a lobar and segmental pulmonary artery and in the aorta) and for dose parameters (CTDI and DLP), using an unpaired t-test. Phantom measurements were also performed for image quality parameters and radiation dose. Results: Mean attenuation was significantly higher in the test group than in the control group in the main pulmonary trunk, in the right pulmonary artery, in the left pulmonary artery, in a lobar and segmental pulmonary artery and in the ascending aorta (all: p <= 0.0001). Noise was significantly higher in the test group than in the control group, but contrast to noise ratio was not significantly different between the two protocols. Radiation dose was significantly lower in the test group than in the control group, as measured by CTDI, DLP and effective dose to organs (all: p < 0.0001). Conclusions: The use of 80 kVp for pulmonary CTA significantly reduces patient radiation exposure, and significantly increases contrast medium attenuation in the pulmonary arteries, with no effect on the diagnostic quality of the exams. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:E580 / E584
页数:5
相关论文
共 50 条
  • [1] Evaluation of CTPA interpreted as limited in pregnant patients suspected for pulmonary embolism
    Cohen, S. . L.
    Wang, J.
    Mankerian, M.
    Feizullayeva, C.
    McCandlish, J. A.
    Barnaby, D.
    Sanelli, P.
    McGinn, T.
    EMERGENCY RADIOLOGY, 2020, 27 (02) : 165 - 171
  • [2] Increasing use of CTPA for the investigation of suspected pulmonary embolism
    Sharma, Sidharth
    Lucas, Christopher D.
    POSTGRADUATE MEDICINE, 2017, 129 (02) : 193 - 197
  • [3] Diagnostic approach and use of CTPA in patients with suspected pulmonary embolism in an emergency department in Saudi Arabia
    Almarshad, Feras
    Alaklabi, Ali
    Al Raizah, Abdulrahman
    AlZahrani, Yousof
    Aljohani, Somaya Awad
    AlShammari, Rawaby Khalid
    Al-mahlawi, Al-zahraa Saleh
    Alahmary, Abdulaziz Abdullah
    Almegren, Mosaad
    Ram, Dushad
    BLOOD RESEARCH, 2023, 58 (01) : 51 - 60
  • [4] Evaluation of CTPA interpreted as limited in pregnant patients suspected for pulmonary embolism
    S . L. Cohen
    J. Wang
    M. Mankerian
    C. Feizullayeva
    J. A. McCandlish
    D. Barnaby
    P. Sanelli
    T. McGinn
    Emergency Radiology, 2020, 27 : 165 - 171
  • [5] CTPA as the gold standard for the diagnosis of pulmonary embolism
    Estrada-Y-Martin, Rosa M.
    Oldham, Sandra A.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2011, 6 (04) : 557 - 563
  • [6] Perfusion SPECT in patients with suspected pulmonary embolism
    Bajc, Marika
    Miniati, Massimo
    Jogi, Jonas
    Stein, Paul D.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 (09) : 1432 - 1437
  • [7] CTPA for clinically suspected pulmonary emboli in oncology patients
    RC Brook
    B Shepherd
    J Smart
    E Rutherford
    K Tung
    Cancer Imaging, 14 (Suppl 1)
  • [8] Prevalence of Pulmonary Embolism in Patients With Suspected Cardioembolic Ischemic Stroke
    Sipola, Petri
    Hedman, Marja
    Jakala, Pekka
    Karjalainen, Anne-Mari
    Peuhkurinen, Keijo
    Manninen, Hannu
    Vanninen, Ritva
    JOURNAL OF THORACIC IMAGING, 2011, 26 (01) : 32 - 35
  • [9] Testing Low-Risk Patients for Suspected Pulmonary Embolism: A Decision Analysis
    Lessler, Adam L.
    Isserman, Joshua A.
    Agarwal, Rajan
    Palevsky, Harold I.
    Pines, Jesse M.
    ANNALS OF EMERGENCY MEDICINE, 2010, 55 (04) : 316 - 326
  • [10] Low concordance between CTPA and echocardiography in identification of right ventricular strain in PERT patients with acute pulmonary embolism
    Lyhne, Mads Dam
    Giordano, Nicholas
    Dudzinski, David
    Torrey, Jasmine
    Wang, Grace
    Zheng, Hui
    Parry, Blair Alden
    Kalra, Mannudeep K.
    Kabrhel, Christopher
    EMERGENCY RADIOLOGY, 2023, 30 (03) : 325 - 331