Solid-phase analytical derivatization for gas-chromatography-mass-spectrometry-based metabolomics

被引:23
|
作者
Takeo, Emi [1 ]
Sasano, Ryoichi [2 ]
Shimma, Shuichi [1 ]
Bamba, Takeshi [1 ,3 ]
Fukusaki, Eiichiro [1 ]
机构
[1] Osaka Univ, Dept Biotechnol, Grad Sch Engn, 2-1 Yamadaoka, Suita, Osaka 5650871, Japan
[2] AiSTI Sci Co Ltd, 120-6 Kuroda, Wakayama 6408341, Japan
[3] Kyushu Univ, Med Inst Bioregulat, Div Metabol, Res Ctr Trans Med,Higashi Ku, 3-1-1 Maidashi, Fukuoka 8128582, Japan
关键词
Derivatization; Sample preparation; Solid phase; Gas chromatography-mass spectrometry; Metabolomics; Amino acids; Organic acids; Organic bases; IN-SITU DERIVATIZATION; MICROEXTRACTION; SAMPLES; URINE; WATER;
D O I
10.1016/j.jbiosc.2017.07.006
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A novel derivatization method for gas chromatography/mass spectrometry (GC/MS)-based metabolomics was developed, based on solid-phase analytical derivatization (SPAD) with methoximation followed by trimethylsilylation. This SPAD method realized derivatization on solid phases combining strong anion exchange with strong cation exchange. To omit a sample condensation process, GC/MS injection was performed using a large-volume injection mode. This mode uses a stomach-shaped insert, and enables a large quantity of sample to be vaporized and introduced into the GC/MS system. In the present study, several parameters were investigated for each SPAD step. The optimal derivatization conditions were determined to be 3-min-methoximation with 5 mu L of >5% methoxyamine solution, and 10-min-tri-methylsilylation with 25 mu L of N-methyl-N-trimethylsilyl-trifluoroacetamide (MSTFA). Derivatized analytes were effectively eluted with 25 mu L of n-hexane. The influences of coexisting substances were also investigated. Coexisting saccharides did not significantly affect the derivatization of analytes. Moreover, saccharides were efficiently washed out using 80% (v/v) acetonitrile in water. The influences of coexisting sodium chloride were negated by dilution of the sample solution with water. The developed method enables the derivatization of both anionic and cationic metabolites, and high-throughput sample preparation. The coverage of detectable metabolites for the developed method was similar to that of the conventional method. This is the first report of a SPAD-based human plasma metabolome analysis protocol. (C) 2017, The Society for Biotechnology, Japan. All rights reserved.
引用
收藏
页码:700 / 706
页数:7
相关论文
共 50 条
  • [21] DETERMINATION OF CHLOROPHENOLS IN WASTEWATER WITH METHYL CHLOROFORMATE DERIVATIZATION, SOLID PHASE EXTRACTION, AND GAS CHROMATOGRAPHY MASS SPECTROMETRY
    Kartal, Aslihan Arslan
    Divrikli, Umit
    Elci, Latif
    ANALYTICAL LETTERS, 2015, 48 (17) : 2723 - 2738
  • [22] Graphene oxide-based dispersive solid-phase extraction combined with in situ derivatization and gas chromatography-mass spectrometry for the determination of acidic pharmaceuticals in water
    Naing, Nyi Nyi
    Li, Sam Fong Yau
    Lee, Hian Kee
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1426 : 69 - 76
  • [23] Fluoroacetylation/fluoroethylesterification as a derivatization approach for gas chromatography-mass spectrometry in metabolomics: Preliminary study of lymphohyperplastic diseases
    Karamani, Anna A.
    Fiamegos, Yiannis Ch.
    Vartholomatos, George
    Stalikas, Constantine D.
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1302 : 125 - 132
  • [24] A tutorial on solid-phase analytical derivatization in sample preparation applications
    Temerdashev, Azamat
    Atapattu, Sanka N.
    Feng, Yu-Qi
    JOURNAL OF CHROMATOGRAPHY OPEN, 2024, 6
  • [25] In situ solid-phase microextraction and post on-fiber derivatization combined with gas chromatography-mass spectrometry for determination of phenol in occupational air
    Es-haghi, Ali
    Baghernejad, Masoud
    Bagheri, Habib
    ANALYTICA CHIMICA ACTA, 2012, 742 : 17 - 21
  • [26] Pipette tip solid-phase extraction and gas chromatography-mass spectrometry for the determination of mequitazine in human plasma
    Kumazawa, Takeshi
    Hasegawa, Chika
    Lee, Xiao-Pen
    Marumo, Akemi
    Shimmen, Natsuko
    Ishii, Akira
    Seno, Hiroshi
    Sato, Keizo
    TALANTA, 2006, 70 (02) : 474 - 478
  • [27] Simultaneous derivatization and extraction of amphetamine-like drugs in urine with headspace solid-phase microextraction followed by gas chromatography-mass spectrometry
    Chia, KJ
    Huang, SD
    ANALYTICA CHIMICA ACTA, 2005, 539 (1-2) : 49 - 54
  • [28] Application of solid-phase microextraction for the determination of organophosphorus pesticides in textiles by gas chromatography with mass spectrometry
    Zhu, Fang
    Ruan, Wenhong
    He, Minheng
    Zeng, Feng
    Luan, Tiangang
    Tong, Yexiang
    Lu, Tongbu
    Ouyang, Gangfeng
    ANALYTICA CHIMICA ACTA, 2009, 650 (02) : 202 - 206
  • [29] Determination of Volatiles in Beer using Solid-Phase Microextraction in Combination with Gas Chromatography/Mass Spectrometry
    Kleinova, Jana
    Klejdus, Borivoj
    CZECH JOURNAL OF FOOD SCIENCES, 2014, 32 (03) : 241 - 248
  • [30] Analysis of pesticides in honey by solid-phase extraction and gas chromatography -: Mass spectrometry
    Albero, B
    Sánchez-Brunete, C
    Tadeo, JL
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2004, 52 (19) : 5828 - 5835