Validation of whole blood impedance aggregometry as a new diagnostic tool for HIT Results of a large Australian study

被引:32
作者
Morel-Kopp, Marie-Christine [1 ,2 ]
Tan, Chee Wee [1 ,2 ]
Brighton, Timothy A. [3 ]
McRae, Simon [4 ]
Baker, Ross [5 ]
Huyen Tran [6 ]
Mollee, Peter [7 ]
Kershaw, Geoffrey [8 ]
Joseph, Joanne [9 ]
Ward, Christopher [1 ,2 ]
机构
[1] Univ Sydney, Kolling Inst Med Res, No Blood Res Ctr, Sydney, NSW 2006, Australia
[2] Royal N Shore Hosp, Dept Haematol & Transfus Med, Sydney, NSW, Australia
[3] Prince Wales Hosp, SEALS, Sydney, NSW, Australia
[4] SA Pathol, Dept Haematol, Adelaide, SA, Australia
[5] Royal Perth Hosp, Dept Haematol, Perth, WA, Australia
[6] Monash Med Ctr, Melbourne, Vic, Australia
[7] Princess Alexandra Hosp, Dept Haematol, Brisbane, Qld 4102, Australia
[8] Royal Prince Alfred Hosp, Sydney, NSW, Australia
[9] St Vincent Hosp, Dept Haematol, Sydney, NSW, Australia
关键词
Heparin; heparin-induced thrombocytopenia; 4T's score; serotonin release assay; whole blood impedance aggregometry; HEPARIN-INDUCED THROMBOCYTOPENIA; PARTICLE GEL IMMUNOASSAY; FLOW-CYTOMETRIC ASSAY; FC RECEPTOR-II; PLATELET-ACTIVATION; MONOCLONAL-ANTIBODIES; 4TS SCORE; MANAGEMENT; MICROPARTICLES; IGG;
D O I
10.1160/TH11-09-0631
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Heparin-induced thrombocytopenia (HIT) remains a challenge, with diagnosis confirmed only by functional assays. The gold standard C-14-serotonin release assay (SRA) is highly sensitive but technically challenging and unsuitable for routine use. We conducted a large study to validate whole blood impedance aggregometry (WBIA) as a suitable diagnostic tool for HIT. WBIA and SRA were used to test 181 samples positive for H-PF4 antibodies by PaGIA or ELISA. Using the same high responder donor, 77 samples were positive by WBIA (aggregation with low-dose but not high-dose heparin). Using the strict definition for SRA positivity, 72 samples were true HIT. In nine samples, serotonin release with high-dose heparin dropped by > 50% but was still >20%; these were retested after a one-half dilution and 8/9 became positive. Ten other samples were discrepant between the two assays: one strongly positive (89% release) and six weakly positive samples by SRA (average release 56%) were WBIA negative. When these samples were retested using a random donor, only two remained SRA positive. Three samples were strongly WBIA positive but SRA negative; two were retested by SRA with 0.51U/ml heparin and one became positive. Under controlled conditions, using the same selected high-responder donor, WBIA and SRA performed similarly with slightly increased sensitivity of the WBIA when using the strict definition of SRA positivity. WBIA is easy to perform with rapid turn-around time and warrants a multi-laboratory trial to complete its validation as a confirmatory assay for platelet-activating HIT antibodies.
引用
收藏
页码:575 / 583
页数:9
相关论文
共 48 条
  • [1] AMIRAL J, 1992, THROMB HAEMOSTASIS, V68, P95
  • [2] AMIRAL J, 1995, THROMB HAEMOSTASIS, V73, P21
  • [3] Bakchoul T, 2009, J THROMB HAEMOST, V103, P145
  • [4] Performance characteristics of two commercially available IgG-specific immunoassays in the assessment of heparin-induced thrombocytopenia (HIT)
    Bakchoul, Tamam
    Giptner, Astrid
    Bein, Gregor
    Santoso, Sentot
    Sachs, Ulrich J. H.
    [J]. THROMBOSIS RESEARCH, 2011, 127 (04) : 345 - 348
  • [5] Clinical characteristics and laboratory testing of patients with suspected HIT: A survey on current practice in 11 university hospitals in France
    Bidet, Audrey
    Poncet, Brigitte Tardy
    Desprez, Dominique
    de Maistre, Emmanuel
    Presles, Emilie
    Lecompte, Thomas
    Lavenu-Bombled, Cecile
    Huisse, Marie Genevieve
    Wolf, Martine
    Morange, Pierre
    Racadot, Evelyne
    Mouton, Christine
    GruneBaum, Lelia
    Pouplard, Claire
    Tardy, Bernard
    [J]. THROMBOSIS RESEARCH, 2010, 125 (06) : E294 - E299
  • [6] Timely diagnosis and management of heparin-induced thrombocytopenia in a frequent request, low incidence single centre using clinical 4T's score and particle gel immunoassay
    Bryant, Adam
    Low, Joyce
    Austin, Steven
    Joseph, Joanne E.
    [J]. BRITISH JOURNAL OF HAEMATOLOGY, 2008, 143 (05) : 721 - 726
  • [7] HEPARIN-INDUCED THROMBOCYTOPENIA - EFFECT OF HEPARIN PLATELET ANTIBODY ON PLATELETS
    CHONG, BH
    GRACE, CS
    ROZENBERG, MC
    [J]. BRITISH JOURNAL OF HAEMATOLOGY, 1981, 49 (04) : 531 - 540
  • [8] A SINGLE AMINO-ACID DISTINGUISHES THE HIGH-RESPONDER FROM THE LOW-RESPONDER FORM OF FC RECEPTOR-II ON HUMAN MONOCYTES
    CLARK, MR
    STUART, SG
    KIMBERLY, RP
    ORY, PA
    GOLDSTEIN, IM
    [J]. EUROPEAN JOURNAL OF IMMUNOLOGY, 1991, 21 (08) : 1911 - 1916
  • [9] Heparin-induced thrombocytopenia: present and future
    Cuker, Adam
    [J]. JOURNAL OF THROMBOSIS AND THROMBOLYSIS, 2011, 31 (03) : 353 - 366
  • [10] Davenport Andrew, 2004, Hemodial Int, V8, P295, DOI 10.1111/j.1492-7535.2004.01108.x