Impact of cochlear tonotopy on electrically evoked compound action potentials (ECAPs)

被引:5
作者
Christov, Florian [1 ,2 ]
Gluth, Michael B. [2 ]
Hans, Stefan [1 ]
Lang, Stephan [1 ]
Arweiler-Harbeck, Diana [1 ]
机构
[1] Univ Klinikum Essen, Dept ENT, Hufelandstr 55, D-45147 Essen, Germany
[2] Univ Chicago, Med Ctr, Dept ENT, Chicago, IL 60637 USA
关键词
CI; cochlear implant; ECAP; NRT; electrode; array; tonotopy; perimodiolar; hearing loss; NEURAL RESPONSE TELEMETRY; ELECTRODE ARRAY; AUDITORY-NERVE; FIBROUS TISSUE; IMPLANTATION; COCHLEOSTOMY; BONE;
D O I
10.1080/00016489.2018.1533993
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Background: A wide range of cochlear implant electrode designs exists. Lateral wall electrodes may be favored for their potential to preserve residual hearing by virtue of being thin and delicate; whereas perimodiolar electrodes may have advantages in case of profound hearing loss, due to electrode positioning in close proximity to the auditory nerve fibers. Aim: The aim of this study was to investigate the impact of these two array designs on the interaction between electrodes and the auditory nerve in different tonotopic regions of the cochlea. Patients and methods: A retrospective study of both adult and pediatric cochlear implant recipients (CI24RE/CI512 or CI422, Cochlear (R)) was undertaken. The differences of threshold Neural Response Telemetry (tNRT) acquired 12 months after surgery were analyzed with respect to the tonotopic location. Results: The results of 168 implants showed that perimodiolar arrays had lowest thresholds in the basal region whereas straight arrays had lowest thresholds in the apex. Highest thresholds for both array types were encountered in the medial parts. Conclusions and Significance: tNRTs differ depending on electrode type and location inside the cochlea. This should be considered pre implantation when choosing the electrode array type and post- implantation when mapping the CI program.
引用
收藏
页码:22 / 26
页数:5
相关论文
共 20 条
[1]   Cochleostomy Versus Round Window Insertions: Influence on Functional Outcomes in Electric-Acoustic Stimulation of the Auditory System [J].
Adunka, Oliver F. ;
Dillon, Margaret T. ;
Adunka, Marcia C. ;
King, English R. ;
Pillsbury, Harold C. ;
Buchman, Craig A. .
OTOLOGY & NEUROTOLOGY, 2014, 35 (04) :613-618
[2]   Quality control after cochlear implant surgery by means of rotational tomography [J].
Aschendorff, A ;
Kubalek, T ;
Turowski, B ;
Zanella, T ;
Hochmuth, T ;
Schumacher, T ;
Klenzner, T ;
Laszig, R .
OTOLOGY & NEUROTOLOGY, 2005, 26 (01) :34-37
[3]   ECAP analysis in cochlear implant patients as a function of patient's age and electrode-design [J].
Christov, F. ;
Munder, P. ;
Berg, L. ;
Bagus, H. ;
Lang, S. ;
Arweiler-Harbeck, D. .
EUROPEAN ANNALS OF OTORHINOLARYNGOLOGY-HEAD AND NECK DISEASES, 2016, 133 :S1-S3
[4]  
Christov F, 2016, OTOLARYNGOL SUNNYVAL, V6, P258
[5]   Cochlear implantation with the nucleus slim modiolar electrode (CI532): a preliminary experience [J].
Cuda, Domenico ;
Murri, Alessandra .
EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2017, 274 (12) :4141-4148
[6]   A comparison between neural response telemetry via cochleostomy or the round window approach in cochlear implantation [J].
Hamerschmidt, Rogerio ;
Schuch, Luiz Henrique ;
Rezende, Rodrigo Kopp ;
Minhoto Wiemes, Gislaine Richter ;
Pires de Oliveira, Adriana Kosma ;
Mocellin, Marcos .
BRAZILIAN JOURNAL OF OTORHINOLARYNGOLOGY, 2012, 78 (04) :71-75
[7]   Correlation between word recognition score and intracochlear new bone and fibrous tissue after cochlear implantation in the human [J].
Kamakura, Takefumi ;
Nadol, Joseph B., Jr. .
HEARING RESEARCH, 2016, 339 :132-141
[8]   Radiological and NRT-Ratio-Based Estimation of Slim Straight Cochlear Implant Electrode Positions: A Multicenter Study [J].
Mittmann, Philipp ;
Todt, Ingo ;
Ernst, Arneborg ;
Rademacher, Grit ;
Mutze, Sven ;
Goericke, Sophia ;
Schlamann, Marc ;
Lang, Stephan ;
Arweiler-Harbeck, Diana ;
Christov, Florian .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2017, 126 (01) :73-78
[9]   Electrophysiological detection of scalar changing perimodiolar cochlear electrode arrays: a long term follow-up study [J].
Mittmann, Philipp ;
Todt, I. ;
Ernst, A. ;
Rademacher, G. ;
Mutze, S. ;
Goericke, S. ;
Schlamann, M. ;
Ramalingam, R. ;
Lang, S. ;
Christov, F. ;
Arweiler-Harbeck, D. .
EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2016, 273 (12) :4251-4256
[10]   Intraoperative findings on ECAP-measurement: Normal or special case? [J].
Mueller, Alexander ;
Hocke, Thomas ;
Mir-Salim, Parwis .
INTERNATIONAL JOURNAL OF AUDIOLOGY, 2015, 54 (04) :257-264