Noninvasive Miniaturized Mass-flow Meter using a Curved Cannula for Implantable Axial Flow Blood Pump

被引:0
|
作者
Kosaka, Ryo [1 ]
Nishida, Masahiro [1 ]
Maruyama, Osamu [1 ]
Yamane, Takashi [1 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Tsukuba, Ibaraki 3058564, Japan
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Blood flow should be measured to monitor conditions of patients with implantable artificial hearts continuously and noninvasively. We have developed a noninvasive miniaturized mass-flow meter using a curved cannula for an axial flow blood pump. The mass-flow meter utilized centrifugal force generated by the mass-flow rate in the curved cannula. Two strain gauges served as sensors. Based on the numerical analysis, the first gauge, attached to the curved area, measured static pressure and centrifugal force, and the second, attached to the straight area, measured static pressure for static pressure compensation. The mass-flow rate was determined by the differences in output from the two gauges. To compensate for the inertia force under the pulsatile flow, a 0.75-Hz low-pass filter was added to the electrical circuit. In the evaluation tests, numerical analysis and an actual measurement test using bovine blood were performed to evaluate the measurement performances. As a result, in the numerical analysis, the relationship between the differential pressure caused by centrifugal force and the flow rate was verified. In the actual measurement test, measurement error was less than +/- 0.5 L/min, and the time delay was 0.12 s. We confirmed that the developed mass-flow meter was able to measure mass-flow rate continuously and noninvasively.
引用
收藏
页码:1343 / 1346
页数:4
相关论文
共 50 条
  • [1] Development of Miniaturized Mass-Flow Meter for an Axial Flow Blood Pump using a Curved Cannula
    Kosaka, Ryo
    Nishida, Masahiro
    Maruyama, Osamu
    Yamane, Takashi
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 2513 - 2516
  • [2] Noninvasive Blood-Flow Meter Using a Curved Cannula with Zero Compensation for an Axial Flow Blood Pump
    Kosaka, Ryo
    Fukuda, Kyohei
    Nishida, Masahiro
    Maruyama, Osamu
    Yamane, Takashi
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 4090 - 4093
  • [3] Development of a miniaturized mass-flow meter for an axial flow blood pump based on computational analysis
    Ryo Kosaka
    Masahiro Nishida
    Osamu Maruyama
    Takashi Yamane
    Journal of Artificial Organs, 2011, 14 : 178 - 184
  • [4] Development of a miniaturized mass-flow meter for an axial flow blood pump based on computational analysis
    Kosaka, Ryo
    Nishida, Masahiro
    Maruyama, Osamu
    Yamane, Takashi
    JOURNAL OF ARTIFICIAL ORGANS, 2011, 14 (03) : 178 - 184
  • [5] Development of miniaturized mass flow meter for an axial flow blood pump
    Kosaka, Ryo
    Maruyama, Osamu
    Nishida, Masahiro
    Yamane, Takashi
    ARTIFICIAL ORGANS, 2007, 31 (05) : 412 - 419
  • [6] Mass-flow meter
    不详
    MICRO, 1995, 13 (05): : 60 - 60
  • [7] THERMAL MASS-FLOW METER
    HUIJSING, JH
    VANDORP, ALC
    LOOS, PJG
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1988, 21 (10): : 994 - 997
  • [8] Flow Visualization in the Outflow Cannula of an Axial Blood Pump
    Liu, Guangmao
    Zhang, Yan
    Chen, Haibo
    Sun, Hansong
    Zhou, Jianye
    Hu, Shengshou
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2014, 24 (01) : 117 - 122
  • [9] Noninvasive pulsatile flow estimation for an implantable rotary blood pump
    Karantonis, Dean M.
    Cloherty, Shaun L.
    Mason, David G.
    Ayre, Peter J.
    Lovell, Nigel H.
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 1018 - +
  • [10] Simulation of Blood Flow Dynamics Changes through Implantable Axial Flow Pump
    Petukhov D.S.
    Telyshev D.V.
    Biomedical Engineering, 2015, 48 (6) : 336 - 340