Non-invasive measurement of reservoir pressure parameters from brachial-cuff blood pressure waveforms

被引:9
作者
Peng, Xiaoqing [1 ]
Schultz, Martin G. [1 ]
Picone, Dean S. [1 ]
Dwyer, Nathan [1 ,2 ]
Black, J. Andrew [1 ,2 ]
Roberts-Thomson, Philip [1 ,2 ]
Sharman, James E. [1 ]
机构
[1] Univ Tasmania, Menzies Inst Med Res, Hobart, Tas, Australia
[2] Royal Hobart Hosp, Hobart, Tas, Australia
基金
英国医学研究理事会;
关键词
arterial blood pressure; hemodynamics; non-invasive; oscillometry; reservoir; CARDIOVASCULAR EVENTS; AORTIC RESERVOIR; EXCESS PRESSURE; VALIDATION; MONITOR; DEVICES;
D O I
10.1111/jch.13411
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Reservoir pressure parameters [eg, reservoir pressure (RP) and excess pressure (XSP)] are biomarkers derived from blood pressure (BP) waveforms that have been shown to predict cardiovascular events independent of conventional cardiovascular risk markers. However, whether RP and XSP can be derived non-invasively from operator-independent cuff device measured brachial or central BP waveforms has never been examined. This study sought to achieve this by comparison of cuff reservoir pressure parameters with intra-aortic reservoir pressure parameters. 162 participants (aged 61 +/- 10 years, 72% male) undergoing coronary angiography had the simultaneous measurement of cuff BP waveforms (via SphygmoCor XCEL, AtCor Medical) and intra-aortic BP waveforms (via fluid-filled catheter). RP and XSP derived from cuff acquired brachial and central BP waveforms were compared with intra-aortic measures. Concordance between brachial-cuff and intra-aortic measurement was moderate-to-good for RP peak (36 +/- 11 vs 48 +/- 14 mm Hg, P < 0.001; ICC 0.77, 95% CI: 0.71-0.82), and poor-to-moderate for XSP peak (28 +/- 10 vs 24 +/- 9 mm Hg, P < 0.001; ICC 0.49, 95% CI: 0.35-0.60). Concordance between central-cuff and intra-aortic measurement was moderate-to-good for RP peak (35 +/- 9 vs 46 +/- 14 mm Hg, P < 0.001; ICC 0.77, 95% CI: 0.70-0.82), but poor for XSP peak (12 +/- 3 vs 24 +/- 9 mm Hg, P < 0.001; ICC 0.12, 95% CI: -0.13 to 0.31). In conclusion, both brachial-cuff and central-cuff methods can reasonably estimate intra-aortic RP, whereas XSP can only be acceptably derived from brachial-cuff BP waveforms. This should enable widespread application to determine the clinical significance, but there is significant room for refinement of the method.
引用
收藏
页码:1703 / 1711
页数:9
相关论文
共 50 条
  • [41] Reliability of non-invasive arterial blood pressure measurement in patients with aneurysmal subarachnoid haemorrhage
    Olsen, Markus Harboe
    Riberholt, Christian Gunge
    Capion, Tenna
    Berg, Ronan M. G.
    Moller, Kirsten
    PHYSIOLOGICAL MEASUREMENT, 2022, 43 (07)
  • [42] Cuff challenges in blood pressure measurement
    Palatini, Paolo
    Asmar, Roland
    JOURNAL OF CLINICAL HYPERTENSION, 2018, 20 (07) : 1100 - 1103
  • [43] Correlation Between Blood Pressure Measurement by Non-invasive and Invasive Methods in Critically-ill Children
    B. Vamshi Krishna
    Suman Das
    Sandip Sen
    Indian Pediatrics, 2018, 55 : 297 - 300
  • [44] Relating external compressing pressure to mean arterial pressure in non-invasive blood pressure measurements
    Chin, K.Y.
    Panerai, R.B.
    Journal of Medical Engineering and Technology, 2015, 39 (01) : 79 - 85
  • [45] Direct estimation of central aortic pressure from measured or quantified mean and diastolic brachial blood pressure: agreement with invasive records
    Bia, Daniel
    Salazar, Federico
    Cinca, Luis
    Gutierrez, Marcos
    Facta, Alvaro
    Zocalo, Yanina
    Diaz, Alejandro
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [46] Correlation Between Blood Pressure Measurement by Non-invasive and Invasive Methods in Critically-ill Children
    Krishna, B. Vamshi
    Das, Suman
    Sen, Sandip
    INDIAN PEDIATRICS, 2018, 55 (04) : 297 - 300
  • [47] Blood pressure in the neonate: Three non-invasive oscillometric pressure monitors compared with invasively measured blood pressure
    Dannevig, I
    Dale, HC
    Liestol, K
    Lindemann, R
    ACTA PAEDIATRICA, 2005, 94 (02) : 191 - 196
  • [48] Evaluation of agreement between invasive and non-invasive blood pressure measurement using the PetMAP™ device in rabbits
    Sredensek, Jerneja
    Zel, Jurij
    Rocchi, Attilio
    Gasparik-Kuels, Nina
    FRONTIERS IN VETERINARY SCIENCE, 2023, 10
  • [49] Effect of mechanical behaviour of the brachial artery on blood pressure measurement during both cuff inflation and cuff deflation
    Zheng, Dingchang
    Pan, Fan
    Murray, Alan
    BLOOD PRESSURE MONITORING, 2013, 18 (05) : 265 - 271
  • [50] Intelligent Estimation of Non-Invasive Blood Pressure from the Electrocardiogram Signal (ECG)
    Moussaoui, Siham
    Chebi, Hocine
    Fellag, Sidali
    Didouche, Yasmina Fadila
    PROGRAM OF THE 2ND INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND AUTOMATIC CONTROL, ICEEAC 2024, 2024,