Non-invasive measurement of reservoir pressure parameters from brachial-cuff blood pressure waveforms

被引:9
|
作者
Peng, Xiaoqing [1 ]
Schultz, Martin G. [1 ]
Picone, Dean S. [1 ]
Dwyer, Nathan [1 ,2 ]
Black, J. Andrew [1 ,2 ]
Roberts-Thomson, Philip [1 ,2 ]
Sharman, James E. [1 ]
机构
[1] Univ Tasmania, Menzies Inst Med Res, Hobart, Tas, Australia
[2] Royal Hobart Hosp, Hobart, Tas, Australia
来源
JOURNAL OF CLINICAL HYPERTENSION | 2018年 / 20卷 / 12期
基金
英国医学研究理事会;
关键词
arterial blood pressure; hemodynamics; non-invasive; oscillometry; reservoir; CARDIOVASCULAR EVENTS; AORTIC RESERVOIR; EXCESS PRESSURE; VALIDATION; MONITOR; DEVICES;
D O I
10.1111/jch.13411
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Reservoir pressure parameters [eg, reservoir pressure (RP) and excess pressure (XSP)] are biomarkers derived from blood pressure (BP) waveforms that have been shown to predict cardiovascular events independent of conventional cardiovascular risk markers. However, whether RP and XSP can be derived non-invasively from operator-independent cuff device measured brachial or central BP waveforms has never been examined. This study sought to achieve this by comparison of cuff reservoir pressure parameters with intra-aortic reservoir pressure parameters. 162 participants (aged 61 +/- 10 years, 72% male) undergoing coronary angiography had the simultaneous measurement of cuff BP waveforms (via SphygmoCor XCEL, AtCor Medical) and intra-aortic BP waveforms (via fluid-filled catheter). RP and XSP derived from cuff acquired brachial and central BP waveforms were compared with intra-aortic measures. Concordance between brachial-cuff and intra-aortic measurement was moderate-to-good for RP peak (36 +/- 11 vs 48 +/- 14 mm Hg, P < 0.001; ICC 0.77, 95% CI: 0.71-0.82), and poor-to-moderate for XSP peak (28 +/- 10 vs 24 +/- 9 mm Hg, P < 0.001; ICC 0.49, 95% CI: 0.35-0.60). Concordance between central-cuff and intra-aortic measurement was moderate-to-good for RP peak (35 +/- 9 vs 46 +/- 14 mm Hg, P < 0.001; ICC 0.77, 95% CI: 0.70-0.82), but poor for XSP peak (12 +/- 3 vs 24 +/- 9 mm Hg, P < 0.001; ICC 0.12, 95% CI: -0.13 to 0.31). In conclusion, both brachial-cuff and central-cuff methods can reasonably estimate intra-aortic RP, whereas XSP can only be acceptably derived from brachial-cuff BP waveforms. This should enable widespread application to determine the clinical significance, but there is significant room for refinement of the method.
引用
收藏
页码:1703 / 1711
页数:9
相关论文
共 50 条
  • [31] Comparison of Non-invasive and Invasive Arterial Blood Pressure Measurement for Assessment of Dynamic Cerebral Autoregulation
    Nils H. Petersen
    Santiago Ortega-Gutierrez
    Andres Reccius
    Arjun Masurkar
    Amy Huang
    Randolph S. Marshall
    Neurocritical Care, 2014, 20 : 60 - 68
  • [32] Evaluation of a continuous non-invasive arterial blood pressure monitoring device in comparison with an arterial blood pressure measurement in the ICU
    K Smolle
    M Schmid
    Critical Care, 15 (Suppl 1):
  • [33] Comparison of Non-invasive and Invasive Arterial Blood Pressure Measurement for Assessment of Dynamic Cerebral Autoregulation
    Petersen, Nils H.
    Ortega-Gutierrez, Santiago
    Reccius, Andres
    Masurkar, Arjun
    Huang, Amy
    Marshall, Randolph S.
    NEUROCRITICAL CARE, 2014, 20 (01) : 60 - 68
  • [34] A procedure for evaluation of non-invasive blood pressure simulators
    Gregor Geršak
    Aleš Žemva
    Janko Drnovšek
    Medical & Biological Engineering & Computing, 2009, 47 : 1221 - 1228
  • [35] A procedure for evaluation of non-invasive blood pressure simulators
    Gersak, Gregor
    Zemva, Ales
    Drnovsek, Janko
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2009, 47 (12) : 1221 - 1228
  • [36] Techniques for Non-Invasive Monitoring of Arterial Blood Pressure
    Meidert, Agnes S.
    Saugel, Bernd
    FRONTIERS IN MEDICINE, 2018, 4
  • [37] Towards continuous non-invasive blood pressure measurements-interpretation of the vasculature response to cuff inflation
    Loureiro, Joao
    Bogatu, Laura
    Schmitt, Lars
    Henriques, Jorge
    Carvalho, Paulo
    Noordergraaf, Gerrit J.
    Paulussen, Igor
    Muehlsteff, Jens
    FRONTIERS IN PHYSIOLOGY, 2023, 14
  • [38] Mean arterial pressure differences between cuff oscillometric and invasive blood pressure
    Picone, Dean S.
    Schultz, Martin G.
    Armstrong, Matthew K.
    Black, J. Andrew
    Dwyer, Nathan
    Roberts-Thomson, Philip
    Weber, Thomas
    Sharman, James E.
    HYPERTENSION RESEARCH, 2025,
  • [39] Reliability of non-invasive arterial blood pressure measurement in patients with aneurysmal subarachnoid haemorrhage
    Olsen, Markus Harboe
    Riberholt, Christian Gunge
    Capion, Tenna
    Berg, Ronan M. G.
    Moller, Kirsten
    PHYSIOLOGICAL MEASUREMENT, 2022, 43 (07)
  • [40] Non-invasive measurement of systolic blood pressure on the arm utilising photoplethysmography: development of the methodology
    Laurent, C
    Jonsson, B
    Vegfors, M
    Lindberg, LG
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2005, 43 (01) : 131 - 135