Non-invasive measurement of reservoir pressure parameters from brachial-cuff blood pressure waveforms

被引:9
|
作者
Peng, Xiaoqing [1 ]
Schultz, Martin G. [1 ]
Picone, Dean S. [1 ]
Dwyer, Nathan [1 ,2 ]
Black, J. Andrew [1 ,2 ]
Roberts-Thomson, Philip [1 ,2 ]
Sharman, James E. [1 ]
机构
[1] Univ Tasmania, Menzies Inst Med Res, Hobart, Tas, Australia
[2] Royal Hobart Hosp, Hobart, Tas, Australia
来源
JOURNAL OF CLINICAL HYPERTENSION | 2018年 / 20卷 / 12期
基金
英国医学研究理事会;
关键词
arterial blood pressure; hemodynamics; non-invasive; oscillometry; reservoir; CARDIOVASCULAR EVENTS; AORTIC RESERVOIR; EXCESS PRESSURE; VALIDATION; MONITOR; DEVICES;
D O I
10.1111/jch.13411
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Reservoir pressure parameters [eg, reservoir pressure (RP) and excess pressure (XSP)] are biomarkers derived from blood pressure (BP) waveforms that have been shown to predict cardiovascular events independent of conventional cardiovascular risk markers. However, whether RP and XSP can be derived non-invasively from operator-independent cuff device measured brachial or central BP waveforms has never been examined. This study sought to achieve this by comparison of cuff reservoir pressure parameters with intra-aortic reservoir pressure parameters. 162 participants (aged 61 +/- 10 years, 72% male) undergoing coronary angiography had the simultaneous measurement of cuff BP waveforms (via SphygmoCor XCEL, AtCor Medical) and intra-aortic BP waveforms (via fluid-filled catheter). RP and XSP derived from cuff acquired brachial and central BP waveforms were compared with intra-aortic measures. Concordance between brachial-cuff and intra-aortic measurement was moderate-to-good for RP peak (36 +/- 11 vs 48 +/- 14 mm Hg, P < 0.001; ICC 0.77, 95% CI: 0.71-0.82), and poor-to-moderate for XSP peak (28 +/- 10 vs 24 +/- 9 mm Hg, P < 0.001; ICC 0.49, 95% CI: 0.35-0.60). Concordance between central-cuff and intra-aortic measurement was moderate-to-good for RP peak (35 +/- 9 vs 46 +/- 14 mm Hg, P < 0.001; ICC 0.77, 95% CI: 0.70-0.82), but poor for XSP peak (12 +/- 3 vs 24 +/- 9 mm Hg, P < 0.001; ICC 0.12, 95% CI: -0.13 to 0.31). In conclusion, both brachial-cuff and central-cuff methods can reasonably estimate intra-aortic RP, whereas XSP can only be acceptably derived from brachial-cuff BP waveforms. This should enable widespread application to determine the clinical significance, but there is significant room for refinement of the method.
引用
收藏
页码:1703 / 1711
页数:9
相关论文
共 50 条
  • [21] Advances in Non-Invasive Blood Pressure Measurement Techniques
    Panula, Tuukka
    Sirkia, Jukka-Pekka
    Wong, David
    Kaisti, Matti
    IEEE REVIEWS IN BIOMEDICAL ENGINEERING, 2023, 16 : 424 - 438
  • [22] Rhabdomyolysis complicating non-invasive blood pressure measurement
    Srinivasan, Chitra
    Kuppuswamy, Balaji
    INDIAN JOURNAL OF ANAESTHESIA, 2012, 56 (04) : 428 - U126
  • [23] New Perspectives on Non-invasive Blood Pressure Measurement
    Argha, Ahmadreza
    Celler, Branko G.
    Yong, Andy
    Rubenis, Imants
    Butlin, Mark
    Avolio, Alberto
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [24] Non-invasive blood pressure measurement displays - a reply
    Bailey, C. R.
    Nathanson, M. H.
    ANAESTHESIA, 2018, 73 (10) : 1300 - 1300
  • [25] NICBPM: Non-Invasive Cuff-less Blood Pressure Monitor
    Aboughaly, Ali A.
    Iqbal, Danyal
    Abd El Ghany, Mohamed A.
    Hofmann, Klaus
    2017 29TH INTERNATIONAL CONFERENCE ON MICROELECTRONICS (ICM), 2017, : 121 - 124
  • [26] Complication of a non-invasive blood pressure cuff during prone positioning
    Kempen, PM
    Meng, L
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2006, 53 (01): : 106 - 106
  • [27] Complication of a non-invasive blood pressure cuff during prone positioning
    Paul M. Kempen
    Li Meng
    Canadian Journal of Anesthesia, 2006, 53 : 106 - 106
  • [28] A New Non-Invasive Cuff-Less Blood Pressure Sensor
    Tu, Tse-Yi
    Chao, Paul C. -P.
    Lee, Yung-Pin
    2013 IEEE SENSORS, 2013, : 857 - 860
  • [29] EFFECT OF NON-INVASIVE BLOOD PRESSURE CUFF INFLATION ON INTRA-ARTERIAL BLOOD PRESSURE VALUES
    Sheshadri, V.
    Tiwari, A.
    Nagappa, M.
    Venkatraghavan, L.
    ANESTHESIA AND ANALGESIA, 2016, 122
  • [30] The peripheral venous pressure changes during non-invasive blood pressure measurement
    Sim, JY
    Choi, Y
    Yoon, MJ
    Lee, DM
    Leem, JW
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1999, 46 (07): : 711 - 712