An integrated device for fast and sensitive immunosuppressant detection

被引:7
作者
Tombelli, Sara [1 ]
Trono, Cosimo [1 ]
Berneschi, Simone [1 ]
Berrettoni, Chiara [1 ]
Giannetti, Ambra [1 ]
Bernini, Romeo [2 ]
Persichetti, Gianluca [2 ]
Testa, Genni [2 ]
Orellana, Guillermo [3 ]
Salis, Francesca [3 ]
Weber, Susanne [4 ]
Luppa, Peter B. [4 ]
Porro, Giampiero [5 ]
Quarto, Giovanna [5 ]
Schubert, Markus [6 ,7 ]
Berner, Marcel [8 ]
Freitas, Paulo P. [9 ]
Cardoso, Susana [9 ]
Franco, Fernando [9 ]
Silverio, Vania [9 ]
Lopez-Martinez, Maria [9 ]
Hilbig, Urs [10 ]
Freudenberger, Kathrin [10 ]
Gauglitz, Gunter [10 ]
Becker, Holger [11 ]
Gartner, Claudia [11 ]
O'Connell, Mark T. [12 ]
Baldini, Francesco [1 ]
机构
[1] CNR IFAC, Inst Appl Phys Nello Carrara, Via Madonna Piano 10, I-50019 Sesto Fiorentino, Italy
[2] CNR IREA, Inst Electromagnet Sensing Environm, Via Diocleziano 328, I-80124 Naples, Italy
[3] Univ Complutense Madrid, Fac Chem, Dept Organ Chem, Madrid 28040, Spain
[4] Tech Univ Munich, Inst Clin Chem & Pathobiochem, Klinikum Rechts Isar, Marchioninistr 15, D-8000 Munich, Germany
[5] Datamed Srl, Via Grandi 4-6, I-20068 Peschiera Garda, Italy
[6] Univ Stuttgart, Inst Photovolta, D-70569 Stuttgart, Germany
[7] Univ Stuttgart, Res Ctr SCoPE, D-70569 Stuttgart, Germany
[8] Innovat Pyrotech GmbH, Steinwerkstr 2, D-71139 Ehningen, Germany
[9] Inst Engn Sistemas & Computadores Microsistemas &, R Alves Redol 9, P-1000027 Lisbon, Portugal
[10] Eberhard Karls Univ Tubingen, Inst Phys & Theoret Chem, Morgenstelle 18, D-72076 Tubingen, Germany
[11] Microfluid ChipShop GmbH, Stockholmer Str 20, D-07747 Jena, Germany
[12] Cornel Med Ltd, 17 Church Walk, St Neots PE19 1JH, Cambs, England
关键词
Immunosuppressant; POCT; Fluorescence; Cyclosporine A; Mycophenolic acid; MAGNETIC NANOPARTICLES; EXPOSURE;
D O I
10.1007/s00216-021-03847-x
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The present paper describes a compact point of care (POC) optical device for therapeutic drug monitoring (TDM). The core of the device is a disposable plastic chip where an immunoassay for the determination of immunosuppressants takes place. The chip is designed in order to have ten parallel microchannels allowing the simultaneous detection of more than one analyte with replicate measurements. The device is equipped with a microfluidic system, which provides sample mixing with the necessary chemicals and pumping samples, reagents and buffers into the measurement chip, and with integrated thin film amorphous silicon photodiodes for the fluorescence detection. Submicrometric fluorescent magnetic particles are used as support in the immunoassay in order to improve the efficiency of the assay. In particular, the magnetic feature is used to concentrate the antibody onto the sensing layer leading to a much faster implementation of the assay, while the fluorescent feature is used to increase the optical signal leading to a larger optical dynamic change and consequently a better sensitivity and a lower limit of detection. The design and development of the whole integrated optical device are here illustrated. In addition, detection of mycophenolic acid and cyclosporine A in spiked solutions and in microdialysate samples from patient blood with the implemented device are reported.
引用
收藏
页码:3243 / 3255
页数:13
相关论文
共 37 条
  • [1] Exposure to Mycophenolic Acid Better Predicts Immunosuppressive Efficacy Than Exposure to Calcineurin Inhibitors in Renal Transplant Patients
    Abdi, Z. Daher
    Premaud, A.
    Essig, M.
    Alain, S.
    Munteanu, E.
    Garnier, F.
    Le Meur, Y.
    Marquet, P.
    Rousseau, A.
    [J]. CLINICAL PHARMACOLOGY & THERAPEUTICS, 2014, 96 (04) : 508 - 515
  • [2] Two immunoassay formats for fully automated CRP detection in human serum
    Albrecht, Christiane
    Kaeppel, Nina
    Gauglitz, Guenter
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 391 (05) : 1845 - 1852
  • [3] On-Site Therapeutic Drug Monitoring
    Ates, H. Ceren
    Roberts, Jason A.
    Lipman, Jeffrey
    Cass, Anthony E. G.
    Urban, Gerald A.
    Dincer, Can
    [J]. TRENDS IN BIOTECHNOLOGY, 2020, 38 (11) : 1262 - 1277
  • [4] An optical PMMA biochip based on fluorescence anisotropy: Application to C-reactive protein assay
    Baldini, Francesco
    Carloni, Adolfo
    Giannetti, Arnbra
    Porro, Giampiero
    Trono, Cosimo
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2009, 139 (01): : 64 - 68
  • [5] Laser-induced fluorescence detection platform for point-of-care testing
    Berner, Marcel
    Hilbig, Urs
    Schubert, Markus B.
    Gauglitz, Guenter
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2017, 28 (08)
  • [6] Silicon thin film photodetectors for multi-channel fluorescence detection in a microfluidic point-of-care testing device
    Berner, Marcel
    Rothemund, Ralph
    Vollmer, Sergej
    Schubert, Markus
    Hilbig, Urs
    Gauglitz, Guenter
    [J]. PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2016, 213 (07): : 1686 - 1696
  • [7] A waveguide absorption filter for fluorescence measurements
    Berneschi, Simone
    Trono, Cosimo
    Bernini, Romeo
    Giannetti, Ambra
    Persichetti, Gianluca
    Testa, Genni
    Tombelli, Sara
    Baldini, Francesco
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2019, 281 : 90 - 95
  • [8] Simultaneous Determination of Protein-Unbound Cyclosporine A and Mycophenolic Acid in Kidney Transplant Patients Using Liquid Chromatography-Tandem Mass Spectrometry
    Bittersohl, Heike
    Herbinger, Juliane
    Wen, Ming
    Renders, Lutz
    Steimer, Werner
    Luppa, Peter B.
    [J]. THERAPEUTIC DRUG MONITORING, 2017, 39 (03) : 211 - 219
  • [9] Therapeutic drug monitoring in the era of precision medicine: opportunities!
    Cremers, Serge
    Guha, Nishan
    Shine, Brian
    [J]. BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 2016, 82 (04) : 900 - 902
  • [10] Usefulness of monitoring free (unbound) concentrations of therapeutic drugs in patient management
    Dasgupta, Amitava
    [J]. CLINICA CHIMICA ACTA, 2007, 377 (1-2) : 1 - 13