Cone-beam-CT guided radiation therapy:: A model for on-line application

被引:179
|
作者
Oldham, M [1 ]
Létourneau, D [1 ]
Watt, L [1 ]
Hugo, G [1 ]
Yan, D [1 ]
Lockman, D [1 ]
Kim, LH [1 ]
Chen, PY [1 ]
Martinez, A [1 ]
Wong, JW [1 ]
机构
[1] William Beaumont Hosp, Dept Radiat Oncol, Royal Oak, MI USA
关键词
cone-beam CT; on-line imaging; IGRT; image-guided therapy;
D O I
10.1016/j.radonc.2005.03.026
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and Purpose: This paper presents efficient and generalized processes for the clinical application of on-line X-ray volumetric cone-beam CT imaging (XVI) to improve the accuracy of patient set-up in radiation therapy. XVI image-guided therapy is illustrated by application to two contrasting sites, intra-cranial radiosurgery and prostate radiation therapy, with very different characteristics regarding organ motion, treatment precision, and imaging conditions. Patients and methods: On-line set-up errors are determined in a two-step process. First the XVI data is registered to the planning data by matching the machine-isocenter with the planning-isocenter, respectively. The machine isocenter is defined in the XVI data during the reconstruction. The planning-isocenter is defined during the planning process in the planning CT data. Set-up errors are then determined from a second registration to remove residual displacements. The accuracy of the entire procedure for on-line set-up error correction was investigated in precision radiosurgery phantom studies. Results: The phantom studies showed that sub-pixel size set-up errors (down to 0.5 mm) can be correctly determined and implemented in the radiosurgery environment. XVI is demonstrated to provide quality skull detail enabling precise skull based on-line alignment in radiosurgery. A 'local XVI' technique was found to give encouraging soft-tissue detail in the high-scatter pelvic environment, enabling on-line soft-tissue based set-up for prostate treatment. The two-step process for determination of set-up errors was found to be efficient and effective when implemented with a dedicated six panel interface enabling simultaneous visualization on the XVI and planning CT data sets. Conclusions: XVI has potential to significantly improve the accuracy of radiation treatments. Present image quality is highly encouraging and can enable bony and soft-tissue patient set-up error determination and correction. As with all image guided treatment techniques the development of efficient procedures to utilize on-line data are of paramount importance. (C) 2005 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:271 / 278
页数:8
相关论文
共 50 条
  • [31] Comprehensive evaluations of cone-beam CT dose in image-guided radiation therapy via GPU-based Monte Carlo simulations
    Montanari, Davide
    Scolari, Enrica
    Silvestri, Chiara
    Graves, Yan Jiang
    Yan, Hao
    Cervino, Laura
    Rice, Roger
    Jiang, Steve B.
    Jia, Xun
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (05) : 1239 - 1253
  • [32] Using cone beam CT to investigate the local geometrical uncertainties during head and neck radiation therapy
    Zeng, G. G.
    Breen, S. L.
    Bayley, A.
    White, E.
    Dawson, L.
    Keller, H.
    Jaffray, D. A.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1785 - +
  • [33] Post-prostatectomy image-guided radiation therapy: Evaluation of toxicity and inter-fraction variation using online cone-beam CT
    Eldredge, Harriet B.
    Studenski, Matthew
    Keith, Scott W.
    Trabulsi, Edouard
    Lallas, Costas D.
    Gomella, Leonard G.
    Dicker, Adam P.
    Showalter, Timothy N.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2011, 55 (05) : 507 - 515
  • [34] Radiation Dose From Cone-Beam CT in Neuroradiology Applications
    Berris, Theocharis
    Gupta, Rajiv
    Rehani, Madan M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (04) : 755 - 761
  • [35] Cone beam CT based image guided radiotherapy: Implementation and clinical use
    de Crevoisier, R.
    Garcia, R.
    Louvel, G.
    Marguet, M.
    Lafond, C.
    Bodez, V.
    CANCER RADIOTHERAPIE, 2009, 13 (6-7): : 482 - 489
  • [36] Cone-Beam CT-Guided Vertebroplasty in a Patient With Vertebra Plana
    Pua, Uei
    Lim, Gavin Hock Tai
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 207 (01) : 196 - 199
  • [37] Prostate Image-Guided Radiotherapy by Megavolt Cone-Beam CT
    Zucca, Sergio
    Carau, Barbara
    Solla, Ignazio
    Garibaldi, Elisabetta
    Farace, Paolo
    Lay, Giancarlo
    Meleddu, Gianfranco
    Gabriele, Pietro
    STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 (08) : 473 - 478
  • [38] Comparison of localization performance with implanted fiducial markers and cone-beam computed tomography for on-line image-guided radiotherapy of the prostate
    Moseley, Douglas J.
    White, Elizabeth A.
    Wiltshire, Kirsty L.
    Rosewall, Tara
    Sharpe, Michael B.
    Siewerdsen, Jeffrey H.
    Bissonnette, Jean-Pierre
    Gospodarowicz, Mary
    Warde, Padraig
    Catton, Charles N.
    Jaffray, David A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (03): : 942 - 953
  • [39] Shading correction for on-board cone-beam CT in radiation therapy using planning MDCT images
    Niu, Tianye
    Sun, Mingshan
    Star-Lack, Josh
    Gao, Hewei
    Fan, Qiyong
    Zhu, Lei
    MEDICAL PHYSICS, 2010, 37 (10) : 5395 - 5406
  • [40] Optimization of four-dimensional cone-beam computed tomography in image-guided radiation therapy of the lung
    Ahmad, Moiz
    Pan, Tinsu
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961