Cone-beam-CT guided radiation therapy:: A model for on-line application

被引:179
|
作者
Oldham, M [1 ]
Létourneau, D [1 ]
Watt, L [1 ]
Hugo, G [1 ]
Yan, D [1 ]
Lockman, D [1 ]
Kim, LH [1 ]
Chen, PY [1 ]
Martinez, A [1 ]
Wong, JW [1 ]
机构
[1] William Beaumont Hosp, Dept Radiat Oncol, Royal Oak, MI USA
关键词
cone-beam CT; on-line imaging; IGRT; image-guided therapy;
D O I
10.1016/j.radonc.2005.03.026
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and Purpose: This paper presents efficient and generalized processes for the clinical application of on-line X-ray volumetric cone-beam CT imaging (XVI) to improve the accuracy of patient set-up in radiation therapy. XVI image-guided therapy is illustrated by application to two contrasting sites, intra-cranial radiosurgery and prostate radiation therapy, with very different characteristics regarding organ motion, treatment precision, and imaging conditions. Patients and methods: On-line set-up errors are determined in a two-step process. First the XVI data is registered to the planning data by matching the machine-isocenter with the planning-isocenter, respectively. The machine isocenter is defined in the XVI data during the reconstruction. The planning-isocenter is defined during the planning process in the planning CT data. Set-up errors are then determined from a second registration to remove residual displacements. The accuracy of the entire procedure for on-line set-up error correction was investigated in precision radiosurgery phantom studies. Results: The phantom studies showed that sub-pixel size set-up errors (down to 0.5 mm) can be correctly determined and implemented in the radiosurgery environment. XVI is demonstrated to provide quality skull detail enabling precise skull based on-line alignment in radiosurgery. A 'local XVI' technique was found to give encouraging soft-tissue detail in the high-scatter pelvic environment, enabling on-line soft-tissue based set-up for prostate treatment. The two-step process for determination of set-up errors was found to be efficient and effective when implemented with a dedicated six panel interface enabling simultaneous visualization on the XVI and planning CT data sets. Conclusions: XVI has potential to significantly improve the accuracy of radiation treatments. Present image quality is highly encouraging and can enable bony and soft-tissue patient set-up error determination and correction. As with all image guided treatment techniques the development of efficient procedures to utilize on-line data are of paramount importance. (C) 2005 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:271 / 278
页数:8
相关论文
共 50 条
  • [21] Liver motion during cone beam computed tomography guided stereotactic body radiation therapy
    Park, Justin C.
    Park, Sung Ho
    Kim, Jong Hoon
    Yoon, Sang Min
    Song, Si Yeol
    Liu, Zhaowei
    Song, Bongyong
    Kauweloa, Kevin
    Webster, Matthew J.
    Sandhu, Ajay
    Mell, Loren K.
    Jiang, Steve B.
    Mundt, Arno J.
    Song, William Y.
    MEDICAL PHYSICS, 2012, 39 (10) : 6431 - 6442
  • [22] Initial results for patient setup verification using transperineal ultrasound and cone beam CT in external beam radiation therapy of prostate cancer
    Anne Richter
    Bülent Polat
    Ingulf Lawrenz
    Stefan Weick
    Otto Sauer
    Michael Flentje
    Frederick Mantel
    Radiation Oncology, 11
  • [23] Initial results for patient setup verification using transperineal ultrasound and cone beam CT in external beam radiation therapy of prostate cancer
    Richter, Anne
    Polat, Buelent
    Lawrenz, Ingulf
    Weick, Stefan
    Sauer, Otto
    Flentje, Michael
    Mantel, Frederick
    RADIATION ONCOLOGY, 2016, 11
  • [24] Commissioning experience with cone-beam computed tomography for image-guided radiation therapy
    Lehmann, Joerg
    Perks, Julian
    Semon, Sheldon
    Harse, Rick
    Purdy, James A.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2007, 8 (03): : 21 - 36
  • [25] Monte Carlo-calculated patient organ doses from kV-cone beam CT in image-guided radiation therapy
    Hioki, Kazunari
    Araki, Fujio
    Ohno, Takeshi
    Tomiyama, Yuuki
    Nakaguchi, Yuji
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2015, 1 (02):
  • [26] Partial delegation to radiation therapists of the control by cone beam CT of prostate positioning
    Benhaim, C.
    Loos, G.
    Achard, J. L.
    Berger, L.
    Caille, C.
    Frederic-Moreau, T.
    Biau, J.
    Lapeyre, M.
    CANCER RADIOTHERAPIE, 2017, 21 (01): : 28 - 33
  • [27] Commissioning kilovoltage cone-beam CT beams in a radiation therapy treatment planning system
    Alaei, Parham
    Spezi, Emiliano
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (06): : 19 - 33
  • [28] A quality assurance program for image quality of cone-beam CT guidance in radiation therapy
    Bissonnette, Jean-Pierre
    Moseley, Douglas J.
    Jaffray, David A.
    MEDICAL PHYSICS, 2008, 35 (05) : 1807 - 1815
  • [29] Application of asymmetric cone-beam CT in radiotherapy
    Yu, LF
    Pelizzari, C
    Pan, XC
    Riem, H
    Munro, P
    Kaissl, W
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3249 - 3252
  • [30] Effect of scattered radiation on image noise in cone beam CT
    Endo, M
    Tsunoo, T
    Nakamori, N
    Yoshida, K
    MEDICAL PHYSICS, 2001, 28 (04) : 469 - 474