Measuring the dependence of the decay curve on the electron energy deposit in NaI(Tl)

被引:12
作者
Choong, W-S [1 ]
Bizarri, G. [1 ]
Cherepy, N. J. [2 ]
Hull, G. [2 ]
Moses, W. W. [1 ]
Payne, S. A. [2 ]
机构
[1] Univ Calif Berkeley, Lawrence Berkeley Lab, Berkeley, CA 94720 USA
[2] Lawrence Livermore Natl Lab, Livermore, CA 94551 USA
关键词
NaI(Tl); Scintillator electron response; Scintillator decay curve; Non-proportionality; Energy resolution; SCINTILLATOR NON-PROPORTIONALITY; LIGHT-PULSE SHAPE; RESOLUTION; CRYSTALS; NONPROPORTIONALITY; EXCITATION; DETECTORS; PARTICLES; FACILITY; CSI(TL);
D O I
10.1016/j.nima.2011.04.053
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We report on the first measurement of the decay times of NaI(Tl) as a function of the deposited electron energy. It has been suggested that the decay curve depends on the ionization density, which is correlated with the electron energy deposit in the scintillator. The ionization creates excitation states, which can decay radiatively and non-radiatively through a number of competing processes. As a result, the rate at which the excitation decays depends on the ionization density. A measurement of the decay curve as a function of the ionization density will allow us to probe the kinetic rates of the competing processes. The Scintillator Light Yield Non-proportionality Characterization Instrument (SLYNCI) measures the electron response of scintillators utilizing fast sampling ADCs to digitize the raw signals from the detectors, and so can provide a measurement of the light pulse shape from the scintillator. Using data collected with the SLYNCI instrument, the intrinsic scintillation profile is extracted on an event-by-event basis by deconvolving the raw signal with the impulse response of the system. Scintillation profiles with the same electron energy deposit are summed to obtain decay curves as a function of the deposited electron energy. The decay time constants are obtained by fitting the decay curves with a two-component exponential decay. While a slight dependence of the decay time constants on the electron energy deposit is observed, the results are not statistically significant. Published by Elsevier B.V.
引用
收藏
页码:95 / 99
页数:5
相关论文
共 22 条
[1]   Progress in Studying Scintillator Proportionality: Phenomenological Model [J].
Bizarri, G. ;
Cherepy, N. J. ;
Choong, W. S. ;
Hull, G. ;
Moses, W. W. ;
Payne, S. A. ;
Singh, J. ;
Valentine, J. D. ;
Vasilev, A. N. ;
Williams, R. T. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (04) :2313-2320
[2]   Design of a facility for measuring scintillator non-proportionality [J].
Choong, W. -S. ;
Vetter, K. M. ;
Moses, W. W. ;
Hull, G. ;
Payne, S. A. ;
Cherepy, N. J. ;
Valentine, J. D. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (03) :1753-1758
[3]   Performance of a facility for measuring scintillator non-proportionality [J].
Choong, Woon-Seng ;
Hull, Giulia ;
Moses, William W. ;
Vetter, Kai M. ;
Payne, Stephen A. ;
Cherepy, Nerine J. ;
Valentine, John D. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (03) :1073-1078
[4]   FLUORESCENT RESPONSE OF NAI(TL) AND CSI(TL) TO X RAYS AND GAMMA RAYS [J].
COLLINSON, AJL ;
HILL, R .
PROCEEDINGS OF THE PHYSICAL SOCIETY OF LONDON, 1963, 81 (523) :883-&
[5]   KINETICS OF SELF-TRAPPED HOLES IN ALKALI-HALIDE CRYSTALS - EXPERIMENTS IN NAI(TI) AND KI(TI) [J].
DIETRICH, HB ;
PURDY, AE ;
MURRAY, RB ;
WILLIAMS, RT .
PHYSICAL REVIEW B, 1973, 8 (12) :5894-5901
[6]   Non-proportionality in the scintillation response and the energy resolution obtainable with scintillation crystals [J].
Dorenbos, P ;
deHaas, JTM ;
vanEijk, CWE .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (06) :2190-2202
[7]  
KAISER WC, 1962, IRE T NUCL SCI, V9, P22
[8]  
Knoll G.F., 1989, Radiation Detection and Measurement, V2nd
[9]   Decay curves of NaI(Tl) scintillators with different Tl+ concentrations under excitation of electrons, alpha particles and fission fragments [J].
Kubota, S ;
Shiraishi, F ;
Takami, Y .
JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1999, 68 (01) :291-297
[10]   APPLICATION OF THE HR-400 MICROCHANNEL PLATE PHOTOMULTIPLIER TO STUDY THE LIGHT-PULSE SHAPE FROM FAST AND SLOW SCINTILLATORS BY MEANS OF THE SINGLE PHOTON METHOD [J].
MOSZYNSKI, M ;
VACHER, J ;
ODRU, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 204 (01) :141-147