Nanochromatography Driven by the Coffee Ring Effect

被引:298
作者
Wong, Tak-Sing [1 ,2 ]
Chen, Ting-Hsuan [1 ]
Shen, Xiaoying [3 ]
Ho, Chih-Ming [1 ]
机构
[1] Univ Calif Los Angeles, Dept Mech & Aerosp Engn, Los Angeles, CA 90095 USA
[2] Harvard Univ, Wyss Inst Biol Inspired Engn, Boston, MA 02115 USA
[3] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
基金
美国国家科学基金会;
关键词
DROPLET; SURFACE; HEALTH; LATEX; FLOW;
D O I
10.1021/ac102963x
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The coffee ring phenomenon has long been known for its ability to concentrate particles at the rim of a dried liquid droplet, yet little is known about its particle separation capability. Here, we elucidate the physics of particle separation during coffee ring formation, which is based on a particle-size selection mechanism near the contact line of an evaporating droplet. On the basis of this mechanism, we demonstrate nanochromatography of three relevant biological entities (proteins, micro-organisms, and mammalian cells) in a liquid droplet, with a separation resolution on the order of similar to 100 nm and a dynamic range from similar to 10 nm to a few tens of micrometers. These findings have direct implications for developing low-cost technologies for disease diagnostics in resource-poor environments.
引用
收藏
页码:1871 / 1873
页数:3
相关论文
共 19 条
[11]   Minimal Size of Coffee Ring Structure [J].
Shen, Xiaoying ;
Ho, Chih-Ming ;
Wong, Tak-Sing .
JOURNAL OF PHYSICAL CHEMISTRY B, 2010, 114 (16) :5269-5274
[12]   Surface morphology of drying latex films: Multiple ring formation [J].
Shmuylovich, L ;
Shen, AQ ;
Stone, HA .
LANGMUIR, 2002, 18 (09) :3441-3445
[13]   Lensfree microscopy on a cellphone [J].
Tseng, Derek ;
Mudanyali, Onur ;
Oztoprak, Cetin ;
Isikman, Serhan O. ;
Sencan, Ikbal ;
Yaglidere, Oguzhan ;
Ozcan, Aydogan .
LAB ON A CHIP, 2010, 10 (14) :1787-1792
[14]   Grand challenges in global health [J].
Varmus, H ;
Klausner, R ;
Zerhouni, E ;
Acharya, T ;
Daar, AS ;
Singer, PA .
SCIENCE, 2003, 302 (5644) :398-399
[15]  
Weisz H., 1970, MICROANALYSIS RING O
[16]   Capillary force repels coffee-ring effect [J].
Weon, Byung Mook ;
Je, Jung Ho .
PHYSICAL REVIEW E, 2010, 82 (01)
[17]   The origins and the future of microfluidics [J].
Whitesides, George M. .
NATURE, 2006, 442 (7101) :368-373
[18]   Microfluidic diagnostic technologies for global public health [J].
Yager, Paul ;
Edwards, Thayne ;
Fu, Elain ;
Helton, Kristen ;
Nelson, Kjell ;
Tam, Milton R. ;
Weigl, Bernhard H. .
NATURE, 2006, 442 (7101) :412-418
[19]  
Zhu HY, 2011, LAB CHIP, V11, P315, DOI [10.1039/c0lc00358a, 10.1039/c01c00358a]