Ventilation Series Similarity: A Study for Ventilation Calculation Using Deformable Image Registration and 4DCT to Avoid Motion Artifacts

被引:1
作者
Zhang, Geoffrey G. [1 ]
Latifi, Kujtim [1 ]
Feygelman, Vladimir [1 ]
Chou, Kuei-Ting [2 ]
Huang, Tzung-Chi [2 ,3 ]
Dilling, Thomas J. [1 ]
Perez, Bradford A. [1 ]
Moros, Eduardo G. [1 ]
机构
[1] H Lee Moffitt Canc Ctr & Res Inst, Radiat Oncol, Tampa, FL USA
[2] China Med Univ, Dept Biomed Imaging & Radiol Sci, Taichung, Taiwan
[3] Asia Univ, Dept Bioinformat & Med Engn, Taichung, Taiwan
关键词
RESOLUTION PULMONARY VENTILATION; COMPUTED-TOMOGRAPHY; REGIONAL VENTILATION; RADIATION-THERAPY; BINNING ALGORITHM; LUNG VENTILATION; CANCER-PATIENTS; CT VENTILATION; 4D-CT; QUANTIFICATION;
D O I
10.1155/2017/9730380
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The major problem with ventilation distribution calculations using DIR and 4DCT is the motion artifacts in 4DCT. Quite often not all phases would exhibit mushroom motion artifacts. If the ventilation series similarity is sufficiently robust, the ventilation distribution can be calculated using only the artifact-free phases. This study investigated the ventilation similarity among the data derived from different respiration phases. Fifteen lung cancer cases were analyzed. In each case, DIR was performed between the end-expiration phase and all other phases. Ventilation distributions were then calculated using the deformation matrices. The similarity was compared between the series ventilation distributions. The correlation between the majority phases was reasonably good, with average SCC values between 0.28 and 0.70 for the original data and 0.30 and 0.75 after smoothing. The better correlation between the neighboring phases, with average SCC values between 0.55 and 0.70 for the original data, revealed the nonlinear property of the dynamic ventilation. DSC analysis showed the same trend. To reduce the errors if motion artifacts are present, the phases without serious mushroom artifacts may be used. To minimize the effect of the nonlinearity in dynamic ventilation, the calculation phase should be chosen as close to the end-inspiration as possible.
引用
收藏
页数:7
相关论文
共 23 条
[1]   Spatial correspondence of 4D CT ventilation and SPECT pulmonary perfusion defects in patients with malignant airway stenosis [J].
Castillo, Richard ;
Castillo, Edward ;
McCurdy, Matthew ;
Gomez, Daniel R. ;
Block, Alec M. ;
Bergsma, Derek ;
Joy, Sarah ;
Guerrero, Thomas .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (07) :1855-1871
[2]   MEASURES OF THE AMOUNT OF ECOLOGIC ASSOCIATION BETWEEN SPECIES [J].
DICE, LR .
ECOLOGY, 1945, 26 (03) :297-302
[3]   Comparison of image registration based measures of regional lung ventilation from dynamic spiral CT with Xe-CT [J].
Ding, Kai ;
Cao, Kunlin ;
Fuld, Matthew K. ;
Du, Kaifang ;
Christensen, Gary E. ;
Hoffman, Eric A. ;
Reinhardt, Joseph M. .
MEDICAL PHYSICS, 2012, 39 (08) :5084-5098
[4]   4DCT-based measurement of changes in pulmonary function following a course of radiation therapy [J].
Ding, Kai ;
Bayouth, John E. ;
Buatti, John M. ;
Christensen, Gary E. ;
Reinhardt, Joseph M. .
MEDICAL PHYSICS, 2010, 37 (03) :1261-1272
[5]   PET-CT image co-registration in the thorax: influence of respiration [J].
Goerres, GW ;
Kamel, E ;
Heidelberg, TNH ;
Schwitter, MR ;
Burger, C ;
von Schulthess, GK .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (03) :351-360
[6]   Quantification of regional ventilation from treatment planning CT [J].
Guerrero, T ;
Sanders, K ;
Noyola-Martinez, J ;
Castillo, E ;
Zhang, Y ;
Tapia, R ;
Guerra, R ;
Borghero, Y ;
Komaki, R .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (03) :630-634
[7]   Objective analysis of tomographic ventilation-perfusion scintigraphy in pulmonary embolism [J].
Harris, Benjamin ;
Bailey, Dale ;
Miles, Susan ;
Bailey, Elizabeth ;
Rogers, Kerry ;
Roach, Paul ;
Thomas, Paul ;
Hensley, Michael ;
King, Gregory G. .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2007, 175 (11) :1173-1180
[8]   IMRT treatment plans and functional planning with functional lung imaging from 4D-CT for thoracic cancer patients [J].
Huang, Tzung-Chi ;
Hsiao, Chien-Yi ;
Chien, Chun-Ru ;
Liang, Ji-An ;
Shih, Tzu-Ching ;
Zhang, Geoffrey G. .
RADIATION ONCOLOGY, 2013, 8
[9]   Evaluation of nonrigid registration models for interfraction dose accumulation in radiotherapy [J].
Janssens, Guillaume ;
de Xivry, Jonathan Orban ;
Fekkes, Stein ;
Dekker, Andre ;
Macq, Benoit ;
Lambin, Philippe ;
van Elmpt, Wouter .
MEDICAL PHYSICS, 2009, 36 (09) :4268-4276
[10]   Validating and improving CT ventilation imaging by correlating with ventilation 4D-PET/CT using 68Ga-labeled nanoparticles [J].
Kipritidis, John ;
Siva, Shankar ;
Hofman, Michael S. ;
Callahan, Jason ;
Hicks, Rodney J. ;
Keall, Paul J. .
MEDICAL PHYSICS, 2014, 41 (01)