USE OF ENERGY DEPOSITION SPECTROMETER LIULIN FOR INDIVIDUAL MONITORING OF AIRCREW

被引:31
作者
Ploc, O. [1 ,2 ]
Brabcova, K. Pachnerova [2 ]
Spurny, F. [2 ]
Malusek, A. [2 ]
Dachev, T. [3 ]
机构
[1] Natl Inst Radiol Sci, Fundamental Technol Ctr, RMR Sect, Chiba 260, Japan
[2] Acad Sci Czech Republic, Dept Radiat Dosimetry, Nucl Phys Inst, Prague, Czech Republic
[3] Bulgarian Acad Sci, Solar Terr Influences Inst, Sofia, Bulgaria
关键词
FLIGHT ALTITUDES; DOSIMETRY;
D O I
10.1093/rpd/ncq505
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Silicon energy deposition spectrometer Liulin was primarily developed for cosmic radiation monitoring onboard spacecrafts. Nowadays, Liulin type detectors are also used to characterise radiation field on board aircraft, at alpine observatories and behind the shielding of heavy ion accelerators. In this work, experiments and calibrations performed in these radiation fields are presented and the method developed for calculation of ambient dose equivalent H*(10) on board aircraft is described. Since 2001, a simple method employing the energy deposition spectra had been used to determine H*(10) on board aircraft but, in 2004, it became clear that the resulting values were strongly biased at locations close to Earth's equator. An improved method for the determination of H*(10) on board aircraft using the Liulin detector was developed. It took into account the composition of the radiation field via the ratio of absorbed doses D-low and D-neut reflecting the contributions from low-LET particles and neutrons, respectively. It resulted in much better agreement with the EPCARD computer code for all aircraft locations; relative differences were within 11 % for low-LET and 20 % for neutron components of H*(10).
引用
收藏
页码:611 / 614
页数:4
相关论文
共 11 条
[1]   Monte Carlo calculation of the angular distribution of cosmic rays at flight altitudes [J].
Battistoni, G ;
Ferrari, A ;
Pelliccioni, M ;
Villari, R .
RADIATION PROTECTION DOSIMETRY, 2004, 112 (03) :331-343
[2]  
*COMM EUR COMM, 1997, 88 COMM EUR COMM OFF
[3]   Characterization of the near Earth radiation environment by Liulin type spectrometers [J].
Dachev, T. P. .
ADVANCES IN SPACE RESEARCH, 2009, 44 (12) :1441-1449
[4]  
Friedberg W., 1992, DOTFAAAM922
[5]  
Lindborg L., 2004, RAD PROT, V140
[6]   ROUTINE INDIVIDUAL MONITORING OF AIRCRAFT CREW EXPOSURE; CZECH EXPERIENCE AND RESULTS 1998-2008 [J].
Malusek, A. ;
Ploc, O. ;
Kovar, I. ;
Brabcova, K. ;
Spurny, F. .
RADIATION PROTECTION DOSIMETRY, 2011, 144 (1-4) :684-687
[7]   The CERN-EU high-energy reference field (CERF) facility for dosimetry at commercial flight altitudes and in space [J].
Mitaroff, A ;
Silari, M .
RADIATION PROTECTION DOSIMETRY, 2002, 102 (01) :7-22
[8]  
PLOC O, 2009, THESIS CTU PRAGUE
[9]   On-board aircrew dosimetry using a semiconductor spectrometer [J].
Spurny, F ;
Dachev, T .
RADIATION PROTECTION DOSIMETRY, 2002, 100 (1-4) :525-528
[10]   Analysis of the calibration results obtained with Liulin-4J spectrometer-dosimeter on protons and heavy ions [J].
Uchihori, Y ;
Kitamura, H ;
Fujitaka, K ;
Dachev, TP ;
Tomov, BT ;
Dimitrov, PG ;
Matviichuk, Y .
RADIATION MEASUREMENTS, 2002, 35 (02) :127-134