One-year efficacy and safety of the Trufill DCS Orbit and Orbit Galaxy detachable coils in the endovascular treatment of intracranial aneurysms: Results from the TRULINE study

被引:1
|
作者
Gory, Benjamin [1 ]
Huot, Laure [2 ]
Riva, Roberto [1 ]
Labeyrie, Paul E. [1 ]
Levrier, Olivier [3 ]
Lebedinsky, Ariel [4 ]
Brunel, Herve [5 ]
Gauvrit, Jean-Yves [6 ]
Blanc, Raphael [7 ]
Chabert, Emmanuel [8 ]
Derex, Laurent [9 ]
Emery, Evelyne [10 ]
Nicolas, Arnaud [11 ]
Desal, Hubert [12 ]
Rodesch, Georges [13 ]
Turjman, Francis [1 ]
机构
[1] Hop Neurolog Pierre Wertheimer, Dept Intervent Neuroradiol, Bron, France
[2] Hosp Civils Lyon, Cellule Innovat DRCI, Lyon, France
[3] Clairval Hosp, Dept Neuroradiol, Marseille, France
[4] Pasteur Hosp, Dept Neuroradiol, Nice, France
[5] Timone Univ Hosp, Dept Neuroradiol, Marseille, France
[6] Pontchaillou Univ Hosp, Dept Neuroradiol, Rennes, France
[7] Rothschild Fondat, Dept Intervent Neuroradiol, Paris, France
[8] Gabriel Montpied Univ Hosp, Dept Neuroradiol, Clermont Ferrand, France
[9] Hop Neurolog Pierre Wertheimer, Stroke Unit, Dept Neurol, Bron, France
[10] Caen Univ Hosp, Dept Neurosurg, Caen, France
[11] DepuySynthes, Codman Neuro, Oberdorf, Switzerland
[12] Nord Laennec Hosp, Dept Neuroradiol, St Herblain, France
[13] Foch Hosp, Dept Neuroradiol, Suresnes, France
关键词
Intracranial aneurysms; coiling; endovascular treatment; recanalization; CEREBRAL ANEURYSMS; CLINICAL-EXPERIENCE; SHORT-TERM; SYSTEM;
D O I
10.1177/1591019917717576
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and purpose: No series reported the mid-term results of Trufill DCS Orbit and Orbit Galaxy detachable coils with independent evaluation. We present the one-year safety and efficacy of these coils in real-life routine clinical practice. Methods: A total of 167 patients with 167 aneurysms (39.1% ruptured) were enrolled in the prospective TRULINE study. The primary endpoint was the safety, assessed by the combined morbidity-mortality rate observed since the time of the procedure and up to one-year follow-up. For safety, primary analyses were performed on intent-to-treat population (attempted coils procedure) and all adverse events have been reviewed by an independent Data Safety Monitoring Board. For efficacy, primary analyses were performed on the per-protocol population (patients treated with more than 70% of Trufill coils and not retreated during the follow-up period) and an independent core laboratory evaluated angiographic results. Results: At one-year post-procedure, neurologic impairment was observed in 6.5% (95% confidence interval: 3.5-11.8) of the patients, and 2.6% (95% confidence interval: 1.0-6.8) had a permanent neurological deterioration. Three deaths were observed, unrelated to the procedure or coils. At one year, complete occlusion was seen in 52 aneurysms (54.2%), neck remnant in 28 aneurysms (29.2%), and aneurysm remnant in 16 aneurysms (16.7%). During the one-year follow-up, the overall incidence of recurrence was 30.2% with a mean interval of 13.84.5 months and the retreatment for major recanalization was needed in nine patients (6.3%). Conclusions: The TRULINE study confirms that endovascular coiling with Trufill DCS Orbit and Orbit Galaxy detachable coils is safe and effective.