O2 release from Hb vesicles evaluated using an artificial, narrow O2-permeable tube:: comparison with RBCs and acellular Hbs

被引:32
作者
Sakai, H
Suzuki, Y
Kinoshita, M
Takeoka, S
Maeda, N
Tsuchida, E [1 ]
机构
[1] Waseda Univ, Adv Res Inst Sci & Engn, Tokyo 1698555, Japan
[2] Ehime Univ, Sch Med, Dept Physiol, Shigenobu, Ehime 7910295, Japan
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 2003年 / 285卷 / 06期
关键词
blood substitutes; red blood cells; hemoglobin; microcirculation; oxygenation; liposome;
D O I
10.1152/ajpheart.00537.2003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A phospholipid vesicle that encapsulates a concentrated hemoglobin (Hb) solution and pyridoxal 5'-phosphate as an allosteric effector [ Hb vesicle (HbV) diameter, 250 nm] has been developed to provide an O-2 carrying ability to plasma expanders. The O-2 release from flowing HbVs was examined using an O-2-permeable, fluorinated ethylenepropylene copolymer tube (inner diameter, 28 mum) exposed to a deoxygenated environment. Measurement of O-2 release was performed using an apparatus that consisted of an inverted microscope and a scanning-grating spectrophotometer with a photon-count detector, and the rate of O-2 release was determined based on the visible absorption spectrum in the Q band of Hb. HbVs and fresh human red blood cells (RBCs) were mixed in various volume ratios at a Hb concentration of 10 g/dl in isotonic saline that contained 5 g/dl albumin, and the suspension was perfused at the centerline flow velocity of 1 mm/s through the narrow tube. The mixtures of acellular Hb solution and RBCs were also tested. Because HbVs were homogeneously dispersed in the albumin solution, increasing the volume of the HbV suspension resulted in a thicker marginal RBC-free layer. Irrespective of the mixing ratio, the rate of O-2 release from the HbV/RBC mixtures was similar to that of RBCs alone. On the other hand, the addition of 50 vol% of acellular Hb solution to RBCs significantly enhanced the rate of deoxygenation. This outstanding difference in the rate of O-2 release between the HbV suspension and the acellular Hb solution should mainly be due to the difference in the particle size ( 250 vs. 7 nm) that affects their diffusion for the facilitated O-2 transport.
引用
收藏
页码:H2543 / H2551
页数:9
相关论文
共 45 条
  • [1] AVNASSENDELFT OR, 1970, SPECTROPHOTOMETRY HA
  • [2] Effect of modifying O2 diffusivity and delivery on glomerular and tubular function in hypoxic perfused kidney
    Baines, AD
    Adamson, G
    Wojciechowski, P
    Pliura, D
    Ho, P
    Kluger, R
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-RENAL PHYSIOLOGY, 1998, 274 (04) : F744 - F752
  • [3] ON-LINE VOLUME FLOW-RATE AND VELOCITY PROFILE MEASUREMENT FOR BLOOD IN MICROVESSELS
    BAKER, M
    WAYLAND, H
    [J]. MICROVASCULAR RESEARCH, 1974, 7 (01) : 131 - 143
  • [4] BAYLISS LE, 1965, J PHYSIOL-LONDON, V179, P1
  • [5] BECK MR, 1980, BIORHEOLOGY, V17, P455
  • [6] Diffusion coefficients of oxygen and hemoglobin measured by facilitated oxygen diffusion through hemoglobin solutions
    Bouwer, ST
    Hoofd, L
    Kreuzer, F
    [J]. BIOCHIMICA ET BIOPHYSICA ACTA-PROTEIN STRUCTURE AND MOLECULAR ENZYMOLOGY, 1997, 1338 (01): : 127 - 136
  • [7] CHANG TMS, 1997, BLOOD SUBSTITUTES PR
  • [8] Analysis of facilitated oxygen transport in a liquid membrane of hemoglobin
    Chen, XS
    Nishide, H
    Tsuchida, E
    [J]. BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1996, 69 (01) : 255 - 259
  • [9] COIN JT, 1979, J BIOL CHEM, V254, P1178
  • [10] Improved oxygenation in ischemic hamster flap tissue is correlated with increasing hemodilution with Hb vesicles and their O2 affinity
    Contaldo, C
    Schramm, S
    Wettstein, R
    Sakai, H
    Takeoka, S
    Tsuchida, E
    Leunig, M
    Banic, A
    Erni, D
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2003, 285 (03): : H1140 - H1147