Volumetric Flow Estimation in a Coronary Artery Phantom Using High-Frame-Rate Contrast-Enhanced Ultrasound, Speckle Decorrelation, and Doppler Flow Direction Detection

被引:1
|
作者
Zhou, Xiaowei [1 ,2 ]
Toulemonde, Matthieu [1 ]
Zhou, Xinhuan [1 ]
Hansen-Shearer, Joseph [1 ]
Senior, Roxy [3 ]
Tang, Meng-Xing [1 ]
机构
[1] Imperial Coll London, Dept Bioengn, London SW7 2AZ, England
[2] Chongqing Med Univ, Sch Biomed Engn, State Key Lab Ultrason Med Engn, Chongqing 400016, Peoples R China
[3] Imperial Coll London, Natl Heart & Lung Inst, London SW7 2AZ, England
基金
英国工程与自然科学研究理事会;
关键词
Ultrasonic imaging; Probes; Volume measurement; Velocity measurement; Doppler effect; Arteries; Ultrasonic variables measurement; High frame rate (HFR); left anterior descending (LAD) coronary artery; microbubbles; speckle decorrelation (SDC); ultrafast; volume flow; NONINVASIVE ASSESSMENT; BLOOD-FLOW; VELOCITY; RESERVE; STENOSIS; COLOR; ECHOCARDIOGRAPHY; VALIDATION; FIELDS; MOTION;
D O I
10.1109/TUFFC.2021.3089723
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The coronary flow reserve (CFR), relating to the volumetric flow rate, is an effective functional parameter to assess the stenosis in the left anterior descending (LAD) coronary artery. We have recently proposed to use high-frame-rate (HFR) contrast-enhanced ultrasound (CEUS) to estimate the volumetric flow rate using ultrasound (US) speckle decorrelation (SDC) without any assumptions about the velocity profile. However, this method still has challenges in imaging deep and small vessels, such as LAD. In this study, we proposed to address the challenges and demonstrate the feasibility of volumetric flow rate measurement in a coronary mimicking phantom with pulsatile flow using a 1-D array cardiac probe, vector Doppler, and an optimal probe rotation/tilting for flow direction detection. Both simulations and in vitro experiments were conducted to validate the proposed method. It is shown that in-plane velocities estimated by vector Doppler under a 10 degrees probe tilting resulted in smaller percentage error (+5.2%) in flow rate estimates than that in US imaging velocimetry (-20.2%) although their relative standard deviations were very close, being 2.6 and 2.8 ml/min, respectively. The flow rate estimated by SDC without direction detection had an error higher than 70%. A 10 degrees tilting of the probe had the best results in flow rate estimation compared to the 5 degrees or 15 degrees tilting. Realistic global motions in the LAD increased the flow rate estimation error from 5.2% to 14.2%. It is concluded that it is feasible to measure the volumetric flow rate in a coronary artery flow phantom with a conventional cardiac probe, using HFR acquisition, Doppler, and SDC analysis. Potentially, this technique could also be applied to investigate the volumetric flow rate in other small vessels similar to the LAD.
引用
收藏
页码:3299 / 3308
页数:10
相关论文
共 46 条
  • [1] 3-D Velocity and Volume Flow Measurement In Vivo Using Speckle Decorrelation and 2-D High-Frame-Rate Contrast-Enhanced Ultrasound
    Zhou, Xiaowei
    Leow, Chee Hau
    Rowland, Ethan
    Riemer, Kai
    Rubin, Jonathan M.
    Weinberg, Peter D.
    Tang, Meng-Xing
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2018, 65 (12) : 2233 - 2244
  • [2] CONTRAST-ENHANCED HIGH-FRAME-RATE ULTRASOUND IMAGING OF FLOW PATTERNS IN CARDIAC CHAMBERS AND DEEP VESSELS
    Vos, Hendrik J.
    Voorneveld, Jason D.
    Jebbink, Erik Groot
    Leow, Chee Hau
    Nie, Luzhen
    van den Bosch, Annemien E.
    Tang, Meng-Xing
    Freear, Steven
    Bosch, Johan G.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2020, 46 (11): : 2875 - 2890
  • [3] High-Frame-Rate Contrast-Enhanced Ultrasound for Velocimetry in the Human Abdominal Aorta
    Voorneveld, Jason
    Engelhard, Stefan
    Vos, Hendrik J.
    Reijnen, Michel M. P. J.
    Gijsen, Frank
    Versluis, Michel
    Jebbink, Erik Groot
    de Jong, Nico
    Bosch, Johan G.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2018, 65 (12) : 2245 - 2254
  • [4] In vitro high-frame-rate contrast-enhanced ultrasound particle image velocimetry in a carotid artery stent
    Hoving, Astrid M.
    Voorneveld, Jason
    de Vries, Evelien E.
    Jebbink, Erik Groot
    Versluis, Michel
    Bosch, Johan G.
    de Jong, Nico
    Mikhal, Julia
    de Borst, Gert J.
    Slump, Cornelis H.
    MEDICAL IMAGING 2018: ULTRASONIC IMAGING AND TOMOGRAPHY, 2018, 10580
  • [5] Qualitative and quantitative analysis of solid renal tumors by high-frame-rate contrast-enhanced ultrasound
    Wu, Hailan
    Shi, Jiayu
    Gao, Long
    Wang, Jingling
    Yuan, WenXin
    Zhang, WeiPing
    Liu, Zhixing
    Mao, Yi
    CANCER IMAGING, 2024, 24 (01)
  • [6] HIGH-FRAME-RATE ULTRASOUND COLOR-ENCODED SPECKLE IMAGING OF COMPLEX FLOW DYNAMICS
    Yiu, Billy Y. S.
    Yu, Alfred C. H.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (06): : 1015 - 1025
  • [7] High-frame-rate contrast-enhanced ultrasound particle image velocimetry in patients with a stented superficial femoral artery: a feasibility study
    van Helvert, Majorie
    Engelhard, Stefan
    Voorneveld, Jason
    van der Vee, Marije
    Bosch, Johan G.
    Versluis, Michel
    Jebbink, Erik Groot
    Reijnen, Michel M. P. J.
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2022, 6 (01)
  • [8] High-frame-rate contrast-enhanced ultrasound particle image velocimetry in patients with a stented superficial femoral artery: a feasibility study
    Majorie van Helvert
    Stefan Engelhard
    Jason Voorneveld
    Marije van der Vee
    Johan G. Bosch
    Michel Versluis
    Erik Groot Jebbink
    Michel M. P. J. Reijnen
    European Radiology Experimental, 6
  • [9] HIGH FRAME RATE CONTRAST-ENHANCED ULTRASOUND IMAGING FOR SLOW LYMPHATIC FLOW: INFLUENCE OF ULTRASOUND PRESSURE AND FLOW RATE ON BUBBLE DISRUPTION AND IMAGE PERSISTENCE
    Zhu, Jiaqi
    Lin, Shengtao
    Leow, Ghee Hau
    Rowland, Ethan M.
    Riemer, Kai
    Harput, Sevan
    Weinberg, Peter D.
    Tang, Meng-Xing
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (09): : 2456 - 2470
  • [10] High-Frame-Rate Contrast-Enhanced Echocardiography Using Diverging Waves: 2-D Motion Estimation and Compensation
    Nie, Luzhen
    Cowell, David M. J.
    Carpenter, Thomas M.
    McLaughlan, James R.
    Cubukcu, Arzu A.
    Freear, Steven
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2019, 66 (02) : 359 - 371