Atomic spectrometry update. Environmental analysis

被引:26
作者
Butler, Owen T. [1 ]
Cairns, Warren [2 ]
Cook, Jennifer M. [3 ]
Davidson, Christine M. [4 ]
机构
[1] Hlth & Safety Lab, Buxton SK17 9JN, England
[2] Univ Ca Foscari, CNR IDPA, I-30123 Venice, Italy
[3] British Geol Survey, Nottingham NG12 5GG, England
[4] Univ Strathclyde, Glasgow G1 1XL, Lanark, Scotland
关键词
INDUCTIVELY-COUPLED PLASMA; INDUCED BREAKDOWN SPECTROSCOPY; X-RAY-FLUORESCENCE; SOLID-PHASE EXTRACTION; LIQUID-LIQUID MICROEXTRACTION; GEOLOGICAL REFERENCE MATERIALS; CERTIFIED REFERENCE MATERIALS; SEDIMENT REFERENCE MATERIALS; CLOUD POINT EXTRACTION; RARE-EARTH-ELEMENTS;
D O I
10.1039/c0ja90038a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This is the twenty-sixth annual review published in JAAS on the application of atomic spectrometry to the chemical analysis of environmental samples. This Update refers to papers published approximately between September 2009 and August 2010 and continues the series of Atomic Spectrometry Updates in Environmental Analysis(1) that should be read in conjunction with other related reviews in the series.(2-6) In the analysis of air, work is ongoing in developing new and existing air sampler devices with an increasing focus on sampling nanoparticles. Determination of mercury in the atmosphere remains a focus for many research groups and this year has seen a renewed interest in sampling and analysis of respirable silica. There is a growing interest in measuring emissions from transport sources such as aviation and shipping. In the field of water analysis, as in previous years, the main areas of activity are the development of preconcentration and extraction procedures and elemental speciation protocols. In the field of soil, plant and related materials analysis, the past year has seen a marked increase in publications featuring LIBS. The technique now appears well established for screening purposes but has not yet convinced detractors of its suitability for use in quantitative multi-element analysis. There is a growing body of literature examining species stability during sample pre-treatment and extraction. Slurry sampling has experienced renewed interest this year. In the field of geological analysis, as in previous years, considerable effort is being spent not only on the production, characterization and certification of new geological reference materials, but also on enhancing the certification of existing reference materials and the development of reference materials with assigned elemental isotopic ratios. Laser ablation continues to go from strength to strength in being adopted as a solid sampling tool within the geochemical community with a growing interest in coupling laser ablation systems to multicollector ICP-MS systems for in situ isotopic analysis. Feedback on this review is most welcome and the lead author can be contacted using the email address provided.
引用
收藏
页码:250 / 286
页数:37
相关论文
共 413 条
[11]   Recent developments in homogeneous and dispersive liquid-liquid extraction for inorganic elements determination. A review [J].
Anthemidis, Aristidis N. ;
Ioannou, Kallirroy-Ioanna G. .
TALANTA, 2009, 80 (02) :413-421
[12]   Design and Computational Fluid Dynamics Investigation of a Personal, High Flow Inhalable Sampler [J].
Anthony, T. Renee ;
Landazuri, Andrea C. ;
Van Dyke, Mike ;
Volckens, John .
ANNALS OF OCCUPATIONAL HYGIENE, 2010, 54 (04) :427-442
[13]   Electrothermal vaporization-inductively coupled plasma-mass spectrometry: A versatile tool for tackling challenging samples A critical review [J].
Aramendia, Maite ;
Resano, Martin ;
Vanhaecke, Frank .
ANALYTICA CHIMICA ACTA, 2009, 648 (01) :23-44
[14]   Correction of structured molecular background by means of high-resolution continuum source electrothermal atomic absorption spectrometry-Determination of antimony in sediment reference materials using direct solid sampling [J].
Araujo, Rennan G. O. ;
Welz, Bernhard ;
Vignola, Fabiola ;
Becker-Ross, Helmut .
TALANTA, 2009, 80 (02) :846-852
[15]   Total reflection X-ray fluorescence selenium analysis after reduction and quartz reflector adsorption [J].
Aretaki, Ioanna-Nikol I. ;
Kallithrakas-Kontos, Nikolaos G. .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2009, 24 (07) :979-982
[16]   Potential of Solid Sampling Electrothermal Vaporization for solving spectral interference in Inductively Coupled Plasma Optical Emission Spectrometry [J].
Asfaw, Alemayehu ;
Wibetoe, Grethe .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2009, 64 (05) :363-368
[17]   Interlaboratory Evaluation of a Standardized Inductively Coupled Plasma Mass Spectrometry Method for the Determination of Trace Beryllium in Air Filter Samples [J].
Ashley, Kevin ;
Brisson, Michael J. ;
Howe, Alan M. ;
Bartley, David L. .
JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2009, 6 (12) :745-750
[18]   Separation, preconcentration and inductively coupled plasma-mass spectrometric (ICP-MS) determination of thorium(IV), titanium(IV), iron(III), lead(II) and chromium(III) on 2-nitroso-1-naphthol impregnated MCI GEL CHP20P resin [J].
Aydin, Funda Armagan ;
Soylak, Mustafa .
JOURNAL OF HAZARDOUS MATERIALS, 2010, 173 (1-3) :669-674
[19]   A sequential extraction to determine the distribution of phosphorus in the seawater and marine surface sediment [J].
Aydin, Isil ;
Aydin, Firat ;
Saydut, Abdurrahman ;
Hamamci, Candan .
JOURNAL OF HAZARDOUS MATERIALS, 2009, 168 (2-3) :664-669
[20]   Complementarity of analytical tools in biomonitoring studies [J].
Ayrault, S. ;
Catinon, M. ;
Clochiatti, R. ;
Tissut, M. ;
Asta, J. .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2009, 281 (01) :131-136