Development of a Dual-Energy Computed Tomography Scoring System for Measurement of Urate Deposition in Gout

被引:43
作者
Bayat, Sara [1 ]
Aati, Opetaia [2 ]
Rech, Juergen [1 ]
Sapsford, Mark [2 ]
Cavallaro, Alexander [1 ]
Lell, Michael [1 ]
Araujo, Elizabeth [1 ]
Petsch, Christina [1 ]
Stamp, Lisa K. [3 ]
Schett, Georg [1 ]
Manger, Bernhard [1 ]
Dalbeth, Nicola [2 ]
机构
[1] Univ Erlangen Nurnberg, Erlangen, Germany
[2] Univ Auckland, Auckland, New Zealand
[3] Univ Otago, Christchurch, New Zealand
关键词
ASYMPTOMATIC HYPERURICEMIA; CRYSTAL DEPOSITION; OMERACT FILTER; CT; ULTRASOUND; ARTHRITIS; CLASSIFICATION; IDENTIFICATION; RHEUMATOLOGY; INVOLVEMENT;
D O I
10.1002/acr.22754
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective. To develop a semiquantitative dual-energy computed tomography (DECT) scoring system for measurement of urate deposition in gout. Methods. Following a structured review of images, a semiquantitative DECT urate scoring method for foot/ankle scans was developed for testing. This method included 4 regions, each scored 0-3, with a maximum total DECT urate score of 12. DECT scans from 224 patients (182 with gout, 42 without gout) were scored by 2 independent readers. Automated urate volumes were also measured. Paired scans from 8 patients receiving pegloticase were analyzed, and a timing exercise was undertaken. The properties of the DECT urate score were analyzed according to the Outcome Measures in Rheumatology (OMERACT) filter. Results. The interreader intraclass correlation coefficient (95% confidence interval) for the DECT urate score was 0.98 (0.97-0.98). All scored regions contributed to the total DECT urate score. DECT urate scores and volumes were highly correlated (r = 0.91, P < 0.0001). Both DECT urate scores and volumes discriminated between gout and nongout control participants and between the tophaceous gout, nontophaceous gout, and control groups. Compared with urate volume, the DECT urate score had greater ability to discriminate between responders and nonresponders to pegloticase therapy (P < 0.001 for DECT urate score and P > 0.05 for volume). The mean +/- SD time required for the DECT urate score was 121 2 seconds and for urate volume was 240 2 seconds (P = 2 x 10(-31)) Conclusion. We have developed a novel semiquantitative DECT scoring method for measurement of urate deposition in the feet/ankles. This method fulfills many aspects of the OMERACT filter.
引用
收藏
页码:769 / 775
页数:7
相关论文
共 24 条
[1]  
Boers M, 1998, J RHEUMATOL, V25, P198
[2]   Developing Core Outcome Measurement Sets for Clinical Trials: OMERACT Filter 2.0 [J].
Boers, Maarten ;
Kirwan, John R. ;
Wells, George ;
Beaton, Dorcas ;
Gossec, Laure ;
d'Agostino, Maria-Antonietta ;
Conaghan, Philip G. ;
Bingham, Clifton O., III ;
Brooks, Peter ;
Landewe, Robert ;
March, Lyn ;
Simon, Lee S. ;
Singh, Jasvinder A. ;
Strand, Vibeke ;
Tugwell, Peter .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 2014, 67 (07) :745-753
[3]   Dual-energy CT for the diagnosis of gout: an accuracy and diagnostic yield study [J].
Bongartz, Tim ;
Glazebrook, Katrina N. ;
Kavros, Steven J. ;
Murthy, Naveen S. ;
Merry, Stephen P. ;
Franz, Walter B., III ;
Michet, Clement J. ;
Veetil, Barath M. Akkara ;
Davis, John M., III ;
Mason, Thomas G., II ;
Warrington, Kenneth J. ;
Ytterberg, Steven R. ;
Matteson, Eric L. ;
Crowson, Cynthia S. ;
Leng, Shuai ;
McCollough, Cynthia H. .
ANNALS OF THE RHEUMATIC DISEASES, 2015, 74 (06) :1072-1077
[4]   Dual energy computed tomography in tophaceous gout [J].
Choi, H. K. ;
Al-Arfaj, A. M. ;
Eftekhari, A. ;
Munk, P. L. ;
Shojania, K. ;
Reid, G. ;
Nicolaou, S. .
ANNALS OF THE RHEUMATIC DISEASES, 2009, 68 (10) :1609-1612
[5]   Dual energy CT in gout: a prospective validation study [J].
Choi, Hyon K. ;
Burns, Lindsay C. ;
Shojania, Kamran ;
Koenig, Nicole ;
Reid, Graham ;
Abufayyah, Mohammed ;
Law, Genevieve ;
Kydd, Alison S. ;
Ouellette, Hugue ;
Nicolaou, Savvas .
ANNALS OF THE RHEUMATIC DISEASES, 2012, 71 (09) :1466-1471
[6]   Relationship between structural joint damage and urate deposition in gout: a plain radiography and dual-energy CT study [J].
Dalbeth, Nicola ;
Aati, Opetaia ;
Kalluru, Ramanamma ;
Gamble, Gregory D. ;
Horne, Anne ;
Doyle, Anthony J. ;
McQueen, Fiona M. .
ANNALS OF THE RHEUMATIC DISEASES, 2015, 74 (06) :1030-1036
[7]   Urate crystal deposition in asymptomatic hyperuricaemia and symptomatic gout: a dual energy CT study [J].
Dalbeth, Nicola ;
House, Meaghan E. ;
Aati, Opetaia ;
Tan, Paul ;
Franklin, Christopher ;
Horne, Anne ;
Gamble, Gregory D. ;
Stamp, Lisa K. ;
Doyle, Anthony J. ;
McQueen, Fiona M. .
ANNALS OF THE RHEUMATIC DISEASES, 2015, 74 (05) :908-911
[8]   Tendon involvement in the feet of patients with gout: a dual-energy CT study [J].
Dalbeth, Nicola ;
Kalluru, Ramanamma ;
Aati, Opetaia ;
Horne, Anne ;
Doyle, Anthony J. ;
McQueen, Fiona M. .
ANNALS OF THE RHEUMATIC DISEASES, 2013, 72 (09) :1545-1548
[9]   Assessment of Tophus Size A Comparison Between Physical Measurement Methods and Dual-Energy Computed Tomography Scanning [J].
Dalbeth, Nicola ;
Aati, Opetaia ;
Gao, Angela ;
House, Meaghan ;
Liu, Qiliang ;
Horne, Anne ;
Doyle, Anthony ;
McQueen, Fiona M. .
JCR-JOURNAL OF CLINICAL RHEUMATOLOGY, 2012, 18 (01) :23-27
[10]   Diagnosis of gout in patients with asymptomatic hyperuricaemia: a pilot ultrasound study [J].
De Miguel, Eugenio ;
Puig, Juan G. ;
Castillo, Concepcion ;
Peiteado, Diana ;
Torres, Rosa J. ;
Martin-Mola, Emilio .
ANNALS OF THE RHEUMATIC DISEASES, 2012, 71 (01) :157-U178