Determination of theophylline in serum by molecularly imprinted solid-phase extraction with pulsed elution

被引:160
作者
Mullett, WM [1 ]
Lai, EPC [1 ]
机构
[1] Carleton Univ, Dept Chem, Ottawa Carleton Chem Inst, Ottawa, ON K1S 5B6, Canada
关键词
D O I
10.1021/ac980264s
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The technique of molecular imprinting is used to produce an extensively cross-linked poly(methacrylic acid-co-ethylene dimethacrylate) material that contains theophylline as a print molecule. After Soxhlet extraction of the theophylline, binding sites are formed in the polymer with complementary size, shape, and positioning of chemical functionalities. The molecularly imprinted polymer's (MIP) high theophylline selectivity, chemical stability, and physically robust nature make it an ideal stationary-phase material in columns for HPLC separation of theophylline from other structurally related drug compounds, Mobile-phase tests confirm that a retention mechanism typical of normal-phase chromatography governs the separation, and selectivity of the MIP column can be controlled by a combination of the mobile phase and the sample solvent. Under optimal conditions, the MIP column functions like a solid-phase sorbent for theophylline extraction. Rapid elution of the bound theophylline can be accomplished in a pulsed format through injection of 20 mu L of a solvent that has the proper polarity and protic nature to disrupt the electrostatic interactions and hydrogen bonding between theophylline and binding sites. A concentration detection limit of 120 ng/mL is obtained using direct UV absorption detection at 270 nm, which corresponds to a mass detection limit of 2.4 ng, This new technique, molecularly imprinted solid-phase extraction with pulsed elution (MISPE-PE), permits on-line preconcentration of theophylline from a large volume of dilute sample solution. Using a sample volume of 300 mu L, a 40 ng/mL standard solution produces a detectable peak signal. Application of MISPE-PE in serum analysis further demonstrates the high capability of the MIP column to selectively isolate theophylline from other matrix components for fast, accurate determination.
引用
收藏
页码:3636 / 3641
页数:6
相关论文
共 32 条
[1]   A highly selective solid phase extraction sorbent for pre-concentration of sameridine made by molecular imprinting [J].
Andersson, LI ;
Paprica, A ;
Arvidsson, T .
CHROMATOGRAPHIA, 1997, 46 (1-2) :57-62
[2]   DESIGNED CATALYSTS - A SYNTHETIC NETWORK POLYMER THAT CATALYZES THE DEHYDROFLUORINATION OF 4-FLUORO-4-(P-NITROPHENYL)BUTAN-2-ONE [J].
BEACH, JV ;
SHEA, KJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1994, 116 (01) :379-380
[3]  
Bouvier ESP, 1997, LC GC-MAG SEP SCI, V15, P152
[4]  
CHANG J, 1982, CLIN CHEM, V28, P361
[5]   Threshold level for theophylline in doping analysis [J].
Delbeke, FT ;
DeBacker, P .
JOURNAL OF CHROMATOGRAPHY B, 1996, 687 (01) :247-252
[6]   METAL-COORDINATION INTERACTIONS IN THE TEMPLATE-MEDIATED SYNTHESIS OF SUBSTRATE-SELECTIVE POLYMERS - RECOGNITION OF BIS(IMIDAZOLE) SUBSTRATES BY COPPER(II) IMINODIACETATE CONTAINING POLYMERS [J].
DHAL, PK ;
ARNOLD, FH .
MACROMOLECULES, 1992, 25 (25) :7051-7059
[7]  
FICHER L, 1991, J AM CHEM SOC, V113, P9358
[8]   Molecularly imprinted uniform-size polymer-based stationary phase for high-performance liquid chromatography - Structural contribution of cross-linked polymer network on specific molecular recognition [J].
Hosoya, K ;
Yoshizako, K ;
Shirasu, Y ;
Kimata, K ;
Araki, T ;
Tanaka, N ;
Haginaka, J .
JOURNAL OF CHROMATOGRAPHY A, 1996, 728 (1-2) :139-147
[9]  
Juarez-Olguin H, 1998, ARCH MED RES, V29, P45
[10]   RECEPTOR-BINDING MIMETICS - A NOVEL MOLECULARLY IMPRINTED POLYMER [J].
KEMPE, M ;
MOSBACH, K .
TETRAHEDRON LETTERS, 1995, 36 (20) :3563-3566