Emphysema Quantification in Inflation-Fixed Lungs Using Low-Dose Computed Tomography and 3He Magnetic Resonance Imaging

被引:8
作者
Gierada, David S. [1 ]
Woods, Jason C. [2 ]
Jacob, Richard E. [2 ]
Bierhals, Andrew J. [1 ]
Choong, Cliff K. [3 ]
Bartel, Seth T. [1 ]
Chang, Yulin V. [2 ]
Das, Nitin A. [3 ]
Hong, Cheng [1 ]
Lutey, Barbara A. [4 ]
Ritter, Jon H. [5 ]
Pilgram, Thomas K. [1 ]
Cooper, Joel D. [3 ]
Patterson, G. Alexander [3 ]
Battafarano, Richard J. [3 ]
Meyers, Bryan F. [3 ]
Yablonskiy, Dmitriy A. [1 ]
Conradi, Mark S. [1 ,2 ]
机构
[1] Washington Univ, Mallinckrodt Inst Radiol, St Louis, MO 63105 USA
[2] Washington Univ, Dept Phys, St Louis, MO 63105 USA
[3] Washington Univ, Div Cardiothorac Surg, St Louis, MO 63105 USA
[4] Washington Univ, Div Pulm & Crit Care Med, St Louis, MO 63105 USA
[5] Washington Univ, Dept Pathol, St Louis, MO 63105 USA
基金
美国国家卫生研究院;
关键词
CT; MR; emphysema; quantitative imaging; CT; DIFFUSION; FIXATION; MRI; DENSITOMETRY; MORPHOMETRY; VENTILATION; HEALTHY; INDEXES; VIVO;
D O I
10.1097/RCT.0b013e3181e480f9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate the use of inflation-fixed lung tissue for emphysema quantification with computed tomography (CT) and He-3 magnetic resonance (MR) diffusion imaging. Methods: Fourteen subjects representing a range of chronic obstructive pulmonary disease severity who underwent complete or lobar lung resection were studied. Computed tomographic measurements of lung attenuation and MR measurements of the hyperpolarized 3He apparent diffusion coefficient (ADC) in resected specimens fixed in inflation with heated formalin vapor were compared with measurements obtained before fixation. Results: The mean (SD) CT emphysema indices were 56% (17%) before and 58% (19%) after fixation (P = 0.77; R = 0.76). Index differences correlated with differences in lung volume (R-2 = 0.47). The mean (SD) He-3 ADCs were 0.40 (0.15) cm(2)/s before and 0.39 (0.14) cm(2)/s after fixation (P = 0.03, R = 0.98). The CT emphysema index and the He-3 ADC were correlated before (R = 0.89) and after fixation (R = 0.79). Conclusions: Concordance of CT and He-3 MR imaging measurements in unfixed and inflation-fixed lungs supports the use of inflation-fixed lungs for quantitative imaging studies in emphysema.
引用
收藏
页码:773 / 779
页数:7
相关论文
共 41 条
[1]   Assessment of lung development using hyperpolarized helium-3 diffusion MR imaging [J].
Altes, Talissa A. ;
Mata, Jaime ;
de lange, Eduard E. ;
Brookeman, James R. ;
Mugler, John P., III .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (06) :1277-1283
[2]   NEW DESIGN FOR FIXATION OF SURGICALLY OBTAINED LUNG SPECIMENS [J].
BARBERA, JA ;
RAMIREZ, J ;
LOPEZ, FA ;
ROCA, J ;
RODRIGUEZROISIN, R .
PATHOLOGY RESEARCH AND PRACTICE, 1989, 184 (06) :630-634
[3]   PORES OF KOHN ARE FILLED IN NORMAL LUNGS - LOW-TEMPERATURE SCANNING ELECTRON-MICROSCOPY [J].
BASTACKY, J ;
GOERKE, J .
JOURNAL OF APPLIED PHYSIOLOGY, 1992, 73 (01) :88-95
[4]   Emphysema: Effect of reconstruction algorithm on CT imaging measures [J].
Boedeker, KL ;
McNitt-Gray, MF ;
Rogers, SR ;
Truong, DA ;
Brown, MS ;
Gjertson, DW ;
Goldin, JG .
RADIOLOGY, 2004, 232 (01) :295-301
[5]   A simple, reproducible, and inexpensive technique in the preparation of explanted emphysematous lungs for ex vivo studies [J].
Choong, CK ;
Haddad, FJ ;
Martinez, C ;
Hu, DZ ;
Pierce, JA ;
Meyers, BF ;
Patterson, GA ;
Cooper, JD .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2005, 130 (03) :922-+
[6]   Hyperpolarized 3He apparent diffusion coefficient MRI of the lung:: Reproducibility and volume dependency in healthy volunteers and patients with emphysema [J].
Diaz, Sandra ;
Casselbrant, Ingrid ;
Piitulainen, Eeva ;
Pettersson, Goran ;
Magnusson, Peter ;
Peterson, Barry ;
Wollmer, Per ;
Leander, Peter ;
Ekberg, Olle ;
Akeson, Per .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (04) :763-770
[7]   Comparison of standard- and low-radiation-dose CT for quantification of emphysema [J].
Gierada, David S. ;
Pilgram, Thomas K. ;
Whiting, Bruce R. ;
Hong, Cheng ;
Bierhals, Andrew J. ;
Kim, Jin Hwan ;
Bae, Kyongtae T. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (01) :42-47
[8]   Effects of CT Section Thickness and Reconstruction Kernel on Emphysema Quantification: Relationship to the Magnitude of the CT Emphysema Index [J].
Gierada, David S. ;
Bierhals, Andrew J. ;
Choong, Cliff K. ;
Bartel, Seth T. ;
Ritter, Jon H. ;
Das, Nitin A. ;
Hong, Cheng ;
Pilgram, Thomas K. ;
Bae, Kyongtae T. ;
Whiting, Bruce R. ;
Woods, Jason C. ;
Hogg, James C. ;
Lutey, Barbara A. ;
Battafarano, Richard J. ;
Cooper, Joel D. ;
Meyers, Bryan F. ;
Patterson, G. Alexander .
ACADEMIC RADIOLOGY, 2010, 17 (02) :146-156
[9]   Effects of Diffusion Time on Short-Range Hyperpolarized 3He Diffusivity Measurements in Emphysema [J].
Gierada, David S. ;
Woods, Jason C. ;
Bierhals, Andrew J. ;
Bartel, Seth T. ;
Ritter, Jon H. ;
Choong, Cliff K. ;
Das, Nitin A. ;
Hong, Cheng ;
Pilgram, Thomas K. ;
Chang, Yulin V. ;
Jacob, Richard E. ;
Hogg, James C. ;
Battafarano, Richard J. ;
Cooper, Joel D. ;
Meyers, Bryan F. ;
Patterson, G. Alexander ;
Yablonskiy, Dmitriy A. ;
Conradi, Mark S. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (04) :801-808
[10]   Repeatability of quantitative CT indexes of emphysema in patients evaluated for lung volume reduction surgery [J].
Gierada, DS ;
Yusen, RD ;
Pilgram, TK ;
Crouch, L ;
Slone, RM ;
Bae, KT ;
Lefrak, SS ;
Cooper, JD .
RADIOLOGY, 2001, 220 (02) :448-454