Preconcentration of diluted biochemical samples using microchannel with integrated nanoscale Nafion membrane

被引:22
作者
Chao, Chen-Chiao [1 ]
Chiu, Ping-Hsien [1 ]
Yang, Ruey-Jen [1 ]
机构
[1] Natl Cheng Kung Univ, Dept Engn Sci, Tainan 70101, Taiwan
关键词
Concentration polarization; Microfluidics; Preconcentration; Nano-junction; ION CONCENTRATION POLARIZATION; SOLID-PHASE EXTRACTION; CAPILLARY-ELECTROPHORESIS; MICROFLUIDIC SYSTEMS; NANOPOROUS MEMBRANES; EXCHANGE MEMBRANES; PROTEINS; CHIP; DEVICE; ENRICHMENT;
D O I
10.1007/s10544-015-9940-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A microfluidic preconcentration device comprising a microchannel and a surface-patterned nanoscale Nafion membrane is proposed. Given the application of an electric field across the chip, the nanopore within Nafion membrane becomes ion selective due to an overlapping of the electric double layer. The resulting difference in flux of the co- and counter-ions within the membrane nanopore prompts the formation of a concentration gradient and leads to a gradual accumulation of the co-ions at the micro-nano junction. It is shown experimentally that the rate of concentration and the preconcentration factor both increase with an increasing electrical field intensity. The preconcentration performance in a straight microchannel is compared with that in a convergent microchannel using fluorescein disodium salt dehydrate and Fluorescein isothiocyanate (FITC)-labeled bovine serum albumin samples. The results show that the reduced cros-ssectional area of the convergent microchannel increases the preconcentration factor compared to that obtained in a straight microchannel and yields a significant reduction in the preconcentration time.
引用
收藏
页数:9
相关论文
共 52 条
[1]   The human plasma proteome - History, character, and diagnostic prospects [J].
Anderson, NL ;
Anderson, NG .
MOLECULAR & CELLULAR PROTEOMICS, 2002, 1 (11) :845-867
[2]   Fluidic preconcentrator device for capillary electrophoresis of proteins [J].
Astorga-Wells, J ;
Swerdlow, H .
ANALYTICAL CHEMISTRY, 2003, 75 (19) :5207-5212
[3]   Current-voltage curves for ion-exchange membranes: A method for determining the limiting current density [J].
Barragan, VM ;
Ruiz-Bauza, C .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1998, 205 (02) :365-373
[4]   Immunomagnetic bead-based cell concentration microdevice for dilute pathogen detection [J].
Beyor, Nathaniel ;
Seo, Tae Seok ;
Liu, Peng ;
Mathies, Richard A. .
BIOMEDICAL MICRODEVICES, 2008, 10 (06) :909-917
[5]   10 000-fold concentration increase in proteins in a cascade microchip using anionic ITP by a 3-D numerical simulation with experimental results [J].
Bottenus, Danny ;
Jubery, Talukder Zaki ;
Dutta, Prashanta ;
Ivory, Cornelius F. .
ELECTROPHORESIS, 2011, 32 (05) :550-562
[6]   OPTIMIZATION IN SAMPLE STACKING FOR HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
BURGI, DS ;
CHIEN, RL .
ANALYTICAL CHEMISTRY, 1991, 63 (18) :2042-2047
[7]   Effects of microchannel geometry on preconcentration intensity in microfluidic chips with straight or convergent-divergent microchannels [J].
Chen, Chia-Lin ;
Yang, Ruey-Jen .
ELECTROPHORESIS, 2012, 33 (05) :751-757
[8]   High Yield Sample Preconcentration Using a Highly Ion-Conductive Charge-Selective Polymer [J].
Chun, Honggu ;
Chung, Taek Dong ;
Ramsey, J. Michael .
ANALYTICAL CHEMISTRY, 2010, 82 (14) :6287-6292
[9]   Transient effects on microchannel electrokinetic filtering with an ion-permselective membrane [J].
Dhopeshwarkar, Rahul ;
Crooks, Richard M. ;
Hlushkou, Dzrnitry ;
Tallarek, Ulrich .
ANALYTICAL CHEMISTRY, 2008, 80 (04) :1039-1048
[10]   Long-range and superfast trapping of DNA molecules in an ac electrokinetic funnel [J].
Du, Jiong-Rong ;
Juang, Yi-Je ;
Wu, Jie-Tang ;
Wei, Hsien-Hung .
BIOMICROFLUIDICS, 2008, 2 (04)