Iron phosphate nanostructures synthesized by microwave method and their applications in biosensing

被引:38
作者
Yin, Yajing [1 ]
Zhang, Hui [1 ]
Wu, Ping [1 ]
Zhou, Bo [1 ]
Cai, Chenxin [1 ]
机构
[1] Nanjing Normal Univ, Jiangsu Key Lab New Power Batteries, Jiangsu Key Lab Biofunct Mat, Lab Electrochem,Coll Chem & Mat Sci, Nanjing 210097, Peoples R China
关键词
DIRECT ELECTRON-TRANSFER; BY-LAYER FILMS; DIRECT ELECTROCHEMISTRY; OXIDATIVE DEHYDROGENATION; HEME-PROTEINS; IONIC LIQUID; HORSERADISH-PEROXIDASE; ANODE MATERIAL; LACTIC-ACID; MYOGLOBIN;
D O I
10.1088/0957-4484/21/42/425504
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A fast, simple microwave heating method has been developed for synthesizing iron phosphate (FePO4) nanostructures. The nanostructures were characterized and confirmed by transmission electronic microscopy (TEM), scanning electronic microscopy (SEM), energy-dispersive x-ray spectroscopy (EDS), x-ray photoelectron spectroscopy (XPS), x-ray powder diffraction (XRD), Fourier transform infrared (FT-IR), and UV-vis spectroscopy. The morphology and the size of the nanomaterials are significantly influenced by the concentration of the precursors and the kinds of surfactants. The nanostructures have been employed as an electrode substrate to immobilize myoglobin (Mb) and to facilitate the direct electron transfer (DET) reaction of the protein. After being immobilized on the nanomaterials, Mb can keep its natural structure and undergo effective DET reaction with a pair of well-defined redox peaks at -(330 +/- 3.0) mV (pH 6.8) and an apparent electron transfer rate constant of 5.54 s(-1). The Mb-FePO4/GC electrode displays good features in the electrocatalytic reduction of H2O2, and thus can be used as a biosensor for detecting substrates with a low detection limit (5 +/- 1 mu M), a wide linear range (0.01-2.5 mM), a high sensitivity (ca. 85 +/- 3 mu A mM(-1) cm(-2)), as well as good stability and reproducibility. Therefore, FePO4 nanomaterials can become a simple and effective biosensing platform for the integration of proteins/enzymes and electrodes, which can provide analytical access to a large group of enzymes for a wide range of bioelectrochemical applications.
引用
收藏
页数:10
相关论文
共 65 条
  • [11] UV resonance Raman determination of protein acid denaturation: Selective unfolding of helical segments of horse myoglobin
    Chi, ZH
    Asher, SA
    [J]. BIOCHEMISTRY, 1998, 37 (09) : 2865 - 2872
  • [12] Highly ordered three-dimensional macroporous FePO4 as cathode materials for lithium-ion batteries
    Cui, Wang-jun
    Liu, Hai-jing
    Wang, Cong-xiao
    Xia, Yong-yao
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (10) : 1587 - 1589
  • [13] Direct electrochemistry and electrocatalysis of myoglobin immobilized on a hexagonal mesoporous silica matrix
    Dai, ZH
    Xu, XX
    Ju, HX
    [J]. ANALYTICAL BIOCHEMISTRY, 2004, 332 (01) : 23 - 31
  • [14] One-step low-temperature route for the preparation of electrochemically active LiMnPO4 powders
    Delacourt, C
    Poizot, P
    Morcrette, M
    Tarascon, JM
    Masquelier, C
    [J]. CHEMISTRY OF MATERIALS, 2004, 16 (01) : 93 - 99
  • [15] Preparation and characterization of room temperature ionic liquid/single-walled carbon nanotube nanocomposites and their application to the direct electrochemistry of heme-containing proteins/enzymes
    Du, Pan
    Liu, Shuna
    Wu, Ping
    Cai, Chenxin
    [J]. ELECTROCHIMICA ACTA, 2007, 52 (23) : 6534 - 6547
  • [16] IDENTICAL MYOGLOBIN IS PRESENT IN BOTH SKELETAL AND SMOOTH MUSCLES OF CHICKEN
    ENOKI, Y
    OHGA, Y
    KAWASE, M
    NAKATANI, A
    [J]. BIOCHIMICA ET BIOPHYSICA ACTA, 1984, 789 (03) : 334 - 341
  • [17] Comparative bioelectrochemical study of two types of myoglobin layer-by-layer films with alumina:: Vapor-surface sol-gel deposited Al2O3 films versus Al2O3 nanoparticle films
    Guo, Wei
    Lu, Haiyun
    Hu, Naifei
    [J]. ELECTROCHIMICA ACTA, 2006, 52 (01) : 123 - 132
  • [18] Electrochemistry and catalysis with myoglobin in hydrated poly(ester sulfonic acid) ionomer films
    Hu, NF
    Rusling, JF
    [J]. LANGMUIR, 1997, 13 (15) : 4119 - 4125
  • [19] Hydrogen peroxide biosensor based on the Electrochemistry of the myoglobin-TATP composite film
    Jian, Fangfang
    Qiao, Yuanbiao
    Yu, Huanqing
    Zhuang, Ruirui
    [J]. ANALYTICAL LETTERS, 2007, 40 (14) : 2664 - 2672
  • [20] Electrochemical performances of FePO4-positive active mass prepared through a new sol-gel method
    Kahoul, A.
    Hammouche, A.
    [J]. IONICS, 2010, 16 (02) : 105 - 109