TREATMENT OF SEPTIC TANK SLUDGE IN A VERTICAL FLOW CONSTRUCTED WETLAND SYSTEM

被引:11
作者
Andrade, Cynthia F. [1 ]
Von Sperling, Marcos [1 ]
Manjate, Elias S. [2 ]
机构
[1] Univ Fed Minas Gerais, Belo Horizonte, MG, Brazil
[2] Univ Eduardo Mondlane, Maputo, Mozambique
来源
ENGENHARIA AGRICOLA | 2017年 / 37卷 / 04期
基金
比尔及梅琳达.盖茨基金会;
关键词
constructed wetlands; septic tank; post-treatment; sludge; FECAL SLUDGE; SEPTAGE TREATMENT; WASTE-WATER; OPERATION; MINERALIZATION; RECIRCULATION; PERFORMANCE; REMOVAL; BEDS; SAND;
D O I
10.1590/1809-4430-Eng.Agric.v37n4p811-819/2017
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
The study consisted of the evaluation of the treatment of septic tank sludge in a vertical constructed wetland system (CW), built according to the first stage of the French system. The system operated also for sewage treatment and one of the beds (area of 29.1 m(2), height of the support medium of 0.7 m and planted with Tifton 85 grass, Cynodon dactylon Pers), began to receive the application of sludge from clean-pit trucks once a week. The percolated liquid was directed to post-treatment in the other two beds of the French system. The application of the raw sludge had average hydraulic loading rate of 13.1 m(3)/m(2). year and solids loading rate of 81 kgTS/m(2). year. The system improved the quality of percolated liquid in terms of carbonaceous and nitrogenous matter (average COD removal efficiencies of 82% and TKN of 63%), but the percolate post-treatment strategy did not result in substantial improvements. The dewatering of the accumulated sludge on top of the bed occurred satisfactorily (55% of dry solids), the Tifton 85 grass was resistant to the operational conditions and the system proved to be a compact technology (sludge treatment capacity of an equivalent population between 1140 and 3799 inhabitants in the unit of 29.1 m(2), corresponding to 39 to 131 inhabitants per m(2) of surface area).
引用
收藏
页码:811 / 819
页数:9
相关论文
共 23 条
[1]  
Andreoli C.V., 2007, SLUDGE TREATMENT DIS
[2]  
Bassan M, 2013, WEDC INT C EG U NAK
[3]  
Brix H, 2014, IWA 14 C WETL SYST W
[4]   Removal of nutrients from septic effluent with re-circulated hybrid tidal flow constructed wetland [J].
Cui, Lihua ;
Feng, Jingkun ;
Ouyang, Ying ;
Deng, Peiwen .
ECOLOGICAL ENGINEERING, 2012, 46 :112-115
[5]   Performance of a system with full- and pilot-scale sludge drying reed bed units treating septic tank sludge in Brazil [J].
Fernanda Calderon-Vallejo, Luisa ;
Andrade, Cynthia Franco ;
Manjate, Elias Sete ;
Arturo Madera-Parra, Carlos ;
von Sperling, Marcos .
WATER SCIENCE AND TECHNOLOGY, 2015, 71 (12) :1751-1759
[6]   Recirculation or artificial aeration in vertical flow constructed wetlands: A comparative study for treating high load wastewater [J].
Foladori, Paola ;
Ruaben, Jenny ;
Ortigara, Angela R. C. .
BIORESOURCE TECHNOLOGY, 2013, 149 :398-405
[7]   Organic matter and nitrogen removal at planted wetlands treating domestic septage with varying operational strategies [J].
Jong, Valerie Siaw Wee ;
Tang, Fu Ee .
WATER SCIENCE AND TECHNOLOGY, 2014, 70 (02) :352-360
[8]   Vertical-flow constructed wetlands as an emerging solution for faecal sludge dewatering in developing countries [J].
Kengne, I. M. ;
Kengne, E. Soh ;
Akoa, Amougou ;
Bemmo, N. ;
Dodane, P. -H. ;
Kone, D. .
JOURNAL OF WATER SANITATION AND HYGIENE FOR DEVELOPMENT, 2011, 1 (01) :13-19
[9]   Treatment of septage in constructed wetlands in tropical climate:: lessons learnt from seven years of operation [J].
Koottatep, T ;
Surinkul, N ;
Polprasert, C ;
Kamal, ASM ;
Koné, D ;
Montangero, A ;
Heinss, U ;
Strauss, M .
WATER SCIENCE AND TECHNOLOGY, 2005, 51 (09) :119-126
[10]   Effect of using different particle sizes of sand as filter media for dewatering faecal sludge [J].
Kuffour, A. R. ;
Awuah, E. ;
Anyemedu, F. O. K. ;
Strauss, M. ;
Kone, D. ;
Cofie, O. .
DESALINATION, 2009, 248 (1-3) :308-314