A randomized trial of Foley balloon induction of labor trial in nulliparas (FIAT-N)

被引:15
作者
Connolly, Katherine A. [1 ]
Kohari, Katherine S. [4 ]
Rekawek, Patricia [1 ]
Smilen, Brooke S. [1 ]
Miller, Meredith R. [1 ]
Moshier, Erin [2 ]
Factor, Stephanie H. [1 ,3 ]
Stone, Joanne L. [1 ]
Bianco, Angela T. [1 ]
机构
[1] Icahn Sch Med Mt Sinai, Dept Obstet Gynecol & Reprod Sci, New York, NY 10029 USA
[2] Icahn Sch Med Mt Sinai, Dept Populat Hlth Sci & Policy, New York, NY 10029 USA
[3] Icahn Sch Med Mt Sinai, Dept Med, New York, NY 10029 USA
[4] Yale Sch Med, Dept Obstet Gynecol & Reprod Sci, New Haven, CT USA
关键词
Foley balloon; induction of labor; oxytocin; CESAREAN DELIVERY; CATHETER; WOMEN;
D O I
10.1016/j.ajog.2016.03.034
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
BACKGROUND: With an increasing rate of induction of labor, it is important to choose induction methods that are safe and efficient in achieving a vaginal delivery. The optimal method for inducing nulliparous women with an unfavorable cervix is not known. OBJECTIVE: We sought to determine if induction of labor with simultaneous use of oxytocin and Foley balloon vs sequential use of Foley balloon followed by oxytocin decreases the time to delivery in nulliparous women. STUDY DESIGN: We conducted a randomized controlled trial of nulliparous women presenting for induction at a single institution from December 2013 through March 2015. After decision for induction was made by their primary provider, women with gestational age >= 24 weeks with a nonanomalous, singleton fetus in vertex presentation with intact membranes were offered participation. Exclusion criteria included history of uterine surgery, unexplained vaginal bleeding, latex allergy, or contraindication to vaginal delivery. Participants were randomized to either simultaneous (oxytocin and Foley balloon) or sequential (oxytocin after expulsion of Foley balloon) induction group. The primary outcome was time from induction to delivery. Secondary outcomes included mode of delivery, estimated blood loss, postpartum hemorrhage, chorioamnionitis, and composite neonatal outcome. Maternal and neonatal outcomes were collected via chart review. Analyses were done on an intention-to-treat basis. RESULTS: A total of 166 patients were enrolled; 82 in the simultaneous and 84 in the sequential group. There were no differences in baseline characteristics in the 2 groups. Patients who received simultaneous oxytocin with insertion of a Foley balloon delivered significantly earlier (15.92 vs 18.87 hours, P = .004) than those in the sequential group. There was no difference in rate of cesarean delivery, estimated blood loss, postpartum hemorrhage, chorioamnionitis, or composite neonatal outcome. CONCLUSION: Simultaneous use of oxytocin and Foley balloon for induction of labor results in a significantly shorter interval to delivery in nulliparas.
引用
收藏
页数:6
相关论文
共 18 条
[1]  
[Anonymous], 2009, Obsetrics Gynecology, V114, P386, DOI [DOI 10.1097/AOG.0B013E3181B48EF5, 10.1097/AOG.0b013e3181b48ef5]
[2]   Prevention and management of postpartum hemorrhage: a comparison of 4 national guidelines [J].
Dahlke, Joshua D. ;
Mendez-Figueroa, Hector ;
Maggio, Lindsay ;
Hauspurg, Alisse K. ;
Sperling, Jeffrey D. ;
Chauhan, Suneet P. ;
Rouse, Dwight J. .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2015, 213 (01) :76.e1-76.e10
[3]   Labor Induction With a Foley Balloon Inflated to 30 mL Compared With 60 mL A Randomized Controlled Trial [J].
Delaney, Shani ;
Shaffer, Brian L. ;
Cheng, Yvonne W. ;
Vargas, Juan ;
Sparks, Teresa N. ;
Paul, Kathleen ;
Caughey, Aaron B. .
OBSTETRICS AND GYNECOLOGY, 2010, 115 (06) :1239-1245
[4]   Predictors of severity in primary postpartum hemorrhage [J].
Ekin, Atalay ;
Gezer, Cenk ;
Solmaz, Ulas ;
Taner, Cuneyt Eftal ;
Dogan, Askin ;
Ozeren, Mehmet .
ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2015, 292 (06) :1247-1254
[5]   Mechanical methods for induction of labour [J].
Jozwiak, Marta ;
Bloemenkamp, Kitty W. M. ;
Kelly, Anthony J. ;
Mol, Ben Willem J. ;
Irion, Olivier ;
Boulvain, Michel .
COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2012, (03)
[6]   A randomized trial comparing a 30-mL and an 80-mL Foley catheter balloon for preinduction cervical ripening [J].
Levy, R ;
Kanengiser, B ;
Furman, B ;
Ben Arie, A ;
Brown, D ;
Hagay, ZJ .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2004, 191 (05) :1632-1636
[7]  
Martin Joyce A, 2015, Natl Vital Stat Rep, V64, P1
[8]   Evaluation of a Transcervical Foley Catheter as a Source of Infection A Systematic Review and Meta-analysis [J].
McMaster, Kristen ;
Sanchez-Ramos, Luis ;
Kaunitz, Andrew M. .
OBSTETRICS AND GYNECOLOGY, 2015, 126 (03) :539-551
[9]   Elective Induction of Labor Compared With Expectant Management of Nulliparous Women at 39 Weeks of Gestation [J].
Miller, Nathaniel R. ;
Cypher, Rebecca L. ;
Foglia, Lisa M. ;
Pates, Jason A. ;
Nielsen, Peter E. .
OBSTETRICS AND GYNECOLOGY, 2015, 126 (06) :1258-1264
[10]   Transcervical Foley catheter with and without oxytocin for cervical ripening - A randomized controlled trial [J].
Pettker, Christian M. ;
Pocock, Sean B. ;
Smok, Dorothy P. ;
Lee, Shing M. ;
Devine, Patricia C. .
OBSTETRICS AND GYNECOLOGY, 2008, 111 (06) :1320-1326