Development of a simulator for the validation of noninvasive blood pressure-monitoring devices

被引:6
作者
Doh, Il [1 ]
Lim, Hyun Kyoon [1 ]
Ahn, Bongyoung [1 ]
机构
[1] KRISS, Ctr Med Metrol, Daejeon, South Korea
关键词
noninvasive blood pressure simulator; oscillometric waveform; pressure pulse; SPHYGMOMANOMETERS; SYSTEM;
D O I
10.1097/MBP.0000000000000174
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
This research aimed to develop a simulator capable of oscillometric pressure pulses recorded from the participants for the validation of oscillometric noninvasive blood pressure (NIBP) devices. The simulator generates the pressure pulses to the cuff connected to NIBP devices depending on the oscillometric waveforms obtained from the participants. Device readings were compared with auscultatory references (systolic and diastolic blood pressures) of the participants. A total of 94 oscillometric waveforms from participants were used in the simulator for the validation of two automated NIBP devices (Omron HEM-7221 and UA-787Plus). For Omron HEM-7221, the differences between device readings and auscultation references for systolic and diastolic blood pressures were 2.82 +/- 7.27 and -4.74 +/- 6.73 mmHg, respectively. UA-787Plus showed differences of 3.26 +/- 5.69 and -3.53 +/- 6.61 mmHg, respectively. Although the number of individual measurements did not fulfill the ISO 81060-2 requirement for clinical validation, criterion 1, where the average of the difference and SD should be lower than +/- 5 and -8 mmHg, was fulfilled. Although the simulator still needs extensive comparative studies to be verified, it could be a potential candidate for a simple and robust tool for the validation and quality control of NIBP devices. Copyright (C) 2016 Wolters Kluwer Health, Inc. All rights reserved.
引用
收藏
页码:189 / 191
页数:3
相关论文
共 7 条
[1]   Can a simulator that regenerates physiological waveforms evaluate oscillometric non-invasive blood pressure devices? [J].
Amoore, JN ;
Vacher, E ;
Murray, IC ;
Mieke, S ;
King, ST ;
Smith, FE ;
Murray, A .
BLOOD PRESSURE MONITORING, 2006, 11 (02) :63-67
[2]   Accuracy of the Welch Allyn Vital Signs Monitor 52000 automatic blood pressure measuring device according to a modified British Hypertension Society protocol [J].
Braam, RL ;
de Maat, C ;
Thien, T .
BLOOD PRESSURE MONITORING, 2002, 7 (03) :185-189
[3]   An arm phantom: A digital simulation system for testing sphygmomanometers [J].
Gross, H ;
Mieke, S ;
Ulbrich, M .
JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1996, 20 (02) :75-83
[4]  
Hung C, 2007, P INT MED INF S TAIW, P1
[5]   Digital recording system of sphygmomanometry [J].
Lee, Jongshill ;
Park, Daekyu ;
Oh, Hongsic ;
Kim, Inyoung ;
Shen, Dongfan ;
Chee, Youngjoon .
BLOOD PRESSURE MONITORING, 2009, 14 (02) :77-81
[6]   Principles and Techniques of Blood Pressure Measurement [J].
Ogedegbe, Gbenga ;
Pickering, Thomas .
CARDIOLOGY CLINICS, 2010, 28 (04) :571-+
[7]   A simulator for oscillometric blood-pressure signals to test automated noninvasive sphygmomanometers [J].
Riedel, W. ;
Mieke, S. ;
Seemann, R. ;
Ittermann, B. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (02)