Effects of malalignment angle on the contact stress of knee prosthesis components, using finite element method

被引:0
作者
Tarnita, Daniela [1 ]
Calafeteanu, Dan Marian [1 ]
Geonea, Ionut Daniel [1 ]
Petcu, Alin [1 ]
Tarnita, Danut-Nicolae [2 ]
机构
[1] Univ Med & Pharm Craiova, Fac Mech, Dept Appl Mech, Craiova, Romania
[2] Univ Med & Pharm Craiova, Fac Med, Dept Human Anat, 2 Petru Rares St, Craiova 200349, Romania
关键词
virtual knee prosthesis; finite element method; contact stress; malalignment; ADAPTIVE BONE PLATE; JOINT; SIMULATION; REPLACEMENT; MODEL; PREDICTION; DESIGN;
D O I
暂无
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
In this paper, the complex 3D virtual model of the prosthetic knee is obtained using embedded applications: DesignModeler and SpaceClaim under ANSYS Workbench 14.5 software package. A number of six cases of prosthetic knee joint assembly, depending on the malalignment angle, are developed. Stress maps and the values of the maximum von Mises stress on the three prosthesis components: polyethylene insert, tibial component and femoral component, for all studied prosthetic knee assemblies were obtained. The results show that as the malalignment angle increases, the values of von Mises stresses increase in all prosthesis components. The parameterized virtual models of the knee prosthesis components allow different changes in shape or dimensions, which can lead to the optimization of the implant and to the improvement of the prosthetic knee biomechanics.
引用
收藏
页码:831 / 836
页数:6
相关论文
共 42 条
[1]   Optimal Design of the Mechanical Systems Using Parametric Technique & MBS (Multi-Body Systems) Software [J].
Alexandru, Catalin .
ADVANCED MATERIALS RESEARCH II, PTS 1 AND 2, 2012, 463-464 :1129-1132
[2]  
[Anonymous], 2009, THESIS
[3]   Biomechanical analysis of the effects of medial meniscectomy on degenerative osteoarthritis [J].
Bae, Ji Yong ;
Park, Kyung Soon ;
Seon, Jong Keun ;
Kwak, Dai Soon ;
Jeon, Insu ;
Song, Eun Kyoo .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2012, 50 (01) :53-60
[4]  
Calafeteanu Dan, 2016, Applied Mechanics and Materials, V823, P143, DOI 10.4028/www.scientific.net/AMM.823.143
[5]  
COLLIER JP, 1991, CLIN ORTHOP RELAT R, P232
[6]   THE REDUNDANT NATURE OF LOCOMOTOR OPTIMIZATION LAWS [J].
COLLINS, JJ .
JOURNAL OF BIOMECHANICS, 1995, 28 (03) :251-267
[7]   Experimental validation of intact and implanted distal femur finite element models [J].
Completo, A. ;
Fonseca, F. ;
Simoes, J. A. .
JOURNAL OF BIOMECHANICS, 2007, 40 (11) :2467-2476
[8]   A finite element model of the human knee joint for the study of tibio-femoral contact [J].
Donahue, TLH ;
Hull, ML ;
Rashid, MM ;
Jacobs, CR .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2002, 124 (03) :273-280
[9]   Dynamic Analysis of an Exoskeleton New Ankle Joint Mechanism [J].
Dumitru, N. ;
Copilusi, C. ;
Geonea, I. ;
Tarnita, D. ;
Dumitrache, I. .
NEW TRENDS IN MECHANISM AND MACHINE SCIENCE: FROM FUNDAMENTALS TO INDUSTRIAL APPLICATIONS, 2015, 24 :709-717
[10]   Design and Simulation of a Single DOF Human-Like Leg Mechanism [J].
Geonea, Ionut Daniel ;
Alexandru, Catalin ;
Margine, Alexandru ;
Ungureanu, Alin .
OPTIROB 2013: OPTIMIZATION OF THE INTELLIGENT SYSTEMS AND THEIR APPLICATIONS IN AEROSPACE, ROBOTICS, MECHANICAL ENGINEERING, MANUFACTURING SYSTEMS, BIOMECHATRONICS AND NEUROREHABILITATION, 2014, 332 :491-496