Quantification of Cold Spots Caused by Geometrical Uncertainty in Field-in-field Techniques for Whole Breast Radiotherapy

被引:8
作者
Nakamura, Naoki [1 ]
Hatanaka, Shogo
Shikama, Naoto [2 ]
Akahane, Keiko
Sekiguchi, Kenji
机构
[1] St Lukes Int Hosp, Dept Radiat Oncol, Chuoh Ku, Tokyo 1048560, Japan
[2] Saitama Med Univ Hosp, Dept Radiat Oncol, Hidaka, Japan
关键词
breast cancer; radiotherapy; whole breast radiotherapy; field-in-field technique; geometrical uncertainty; INTENSITY MODULATION; DOSE DISTRIBUTIONS; IRRADIATION; IMRT; MOTION;
D O I
10.1093/jjco/hyr112
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objective: To quantify the cold spot under geometrical uncertainties in field-in-field techniques for whole breast radiotherapy. Methods: Ten consecutive patients from both the left-and right-sided treatment site groups who received whole breast radiotherapy with the field-in-field technique were included. Virtual plans were made with moving isocenters to the posterior direction having two amplitudes (5 and 10 mm) and prescribing the same monitor unit as the original plan (FIF_5 and FIF_10). The planning target volume for evaluation was defined by subtracting the areas within 5 mm from the skin and within 5 mm from the lung from the whole breast. The differences in V90, V95 and D98 of planning target volume for evaluation were measured between the original and virtual plans. As a reference, the same measurements were taken for the wedge techniques (Wedge_5 and Wedge_10). Results: The differences in V95 were -0.2% on FIF_5, -1.7% on FIF_10, -0.5% on Wedge_5 and -1.5% on Wedge_10. The differences in V90 were -0.02% on FIF_5, -0.3% on FIF_10, 0.05% on Wedge_5 and 0.1% on Wedge_10. The differences in D98 were 0 Gy on FIF_5, -0.1 Gy on FIF_10, -0.2 Gy on Wedge_5 and -0.4 Gy on Wedge_10. The differences in D98 between the original plans and virtual scenarios for field-in-field techniques were significantly smaller than those for wedge techniques, but there were no statically significant differences in V90 and V95. Conclusions: The quantity of the cold spots caused by the geometrical uncertainties in field-in-field techniques was similar to that for the wedge techniques and was acceptable.
引用
收藏
页码:1127 / 1131
页数:5
相关论文
共 11 条
[11]   Impact of geometrical uncertainties on 3D CRT and IMRT dose distributions for lung cancer treatment [J].
Schwarz, Marco ;
Van Der Geer, Joris ;
Van Herk, Marcel ;
Lebesque, Joos V. ;
Mijnheer, Ben J. ;
Damen, Eugene M. F. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (04) :1260-1269