Quantification of Cold Spots Caused by Geometrical Uncertainty in Field-in-field Techniques for Whole Breast Radiotherapy

被引:8
作者
Nakamura, Naoki [1 ]
Hatanaka, Shogo
Shikama, Naoto [2 ]
Akahane, Keiko
Sekiguchi, Kenji
机构
[1] St Lukes Int Hosp, Dept Radiat Oncol, Chuoh Ku, Tokyo 1048560, Japan
[2] Saitama Med Univ Hosp, Dept Radiat Oncol, Hidaka, Japan
关键词
breast cancer; radiotherapy; whole breast radiotherapy; field-in-field technique; geometrical uncertainty; INTENSITY MODULATION; DOSE DISTRIBUTIONS; IRRADIATION; IMRT; MOTION;
D O I
10.1093/jjco/hyr112
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objective: To quantify the cold spot under geometrical uncertainties in field-in-field techniques for whole breast radiotherapy. Methods: Ten consecutive patients from both the left-and right-sided treatment site groups who received whole breast radiotherapy with the field-in-field technique were included. Virtual plans were made with moving isocenters to the posterior direction having two amplitudes (5 and 10 mm) and prescribing the same monitor unit as the original plan (FIF_5 and FIF_10). The planning target volume for evaluation was defined by subtracting the areas within 5 mm from the skin and within 5 mm from the lung from the whole breast. The differences in V90, V95 and D98 of planning target volume for evaluation were measured between the original and virtual plans. As a reference, the same measurements were taken for the wedge techniques (Wedge_5 and Wedge_10). Results: The differences in V95 were -0.2% on FIF_5, -1.7% on FIF_10, -0.5% on Wedge_5 and -1.5% on Wedge_10. The differences in V90 were -0.02% on FIF_5, -0.3% on FIF_10, 0.05% on Wedge_5 and 0.1% on Wedge_10. The differences in D98 were 0 Gy on FIF_5, -0.1 Gy on FIF_10, -0.2 Gy on Wedge_5 and -0.4 Gy on Wedge_10. The differences in D98 between the original plans and virtual scenarios for field-in-field techniques were significantly smaller than those for wedge techniques, but there were no statically significant differences in V90 and V95. Conclusions: The quantity of the cold spots caused by the geometrical uncertainties in field-in-field techniques was similar to that for the wedge techniques and was acceptable.
引用
收藏
页码:1127 / 1131
页数:5
相关论文
共 11 条
[1]   Dosimetric improvements following 3D planning of tangential breast irradiation [J].
Aref, A ;
Thornton, D ;
Youssef, E ;
He, T ;
Tekyi-Mensah, S ;
Denton, L ;
Ezzell, G .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (05) :1569-1574
[2]   The sensitivity of dose distributions for organ motion and set-up uncertainties in prostate IMRT [J].
Bos, LJ ;
van der Geer, J ;
van Herk, M ;
Mijnheer, BJ ;
Lebesque, JV ;
Damen, EMF .
RADIOTHERAPY AND ONCOLOGY, 2005, 76 (01) :18-26
[3]   Dosimetric analysis of intact breast irradiation in off-axis planes [J].
Buchholz, TA ;
Gurgoze, E ;
Bice, WS ;
Prestidge, BR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (01) :261-267
[4]   A comparison of different intensity modulation treatment techniques for tangential breast irradiation [J].
Chang, SX ;
Deschesne, KM ;
Cullip, TJ ;
Parker, SA ;
Earnhart, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (05) :1305-1314
[5]  
de la Torre Ninet, 2004, Med Dosim, V29, P109, DOI 10.1016/j.meddos.2004.03.002
[6]   Evaluation of compensation in breast radiotherapy: A planning study using multiple static fields [J].
Donovan, EM ;
Johnson, U ;
Shentall, G ;
Evans, PM ;
Neal, AJ ;
Yarnold, JR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 46 (03) :671-679
[7]   Intensity modulation under geometrical uncertainty: a deconvolution approach to robust fluence [J].
Fan, Yankhua ;
Nath, Ravinder .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (14) :4029-4045
[8]   Inter-fraction motion and dosimetric consequences during breast intensity-modulated radiotherapy (IMRT) [J].
Jain, Popja ;
Marchant, Tom ;
Green, Melanie ;
Watkins, Gillian ;
Davies, Julie ;
McCarthy, Claire ;
Loncaster, Juliette ;
Stewart, Alan ;
Magee, Brian ;
Moore, Christopher ;
Price, Pat .
RADIOTHERAPY AND ONCOLOGY, 2009, 90 (01) :93-98
[9]   Performance evaluation of field-in-field technique for tangential breast irradiation [J].
Lee, Jeong-Woo ;
Hong, Semie ;
Choi, Kyoung-Sik ;
Kim, Yon-Lae ;
Park, Byung-Moon ;
Chung, Jin-Beom ;
Lee, Doo-Hyun ;
Suh, Tae-Suk .
JAPANESE JOURNAL OF CLINICAL ONCOLOGY, 2008, 38 (02) :158-163
[10]   Intensity modulation for breast treatment using static multi-leaf collimators [J].
Lo, YC ;
Yasuda, G ;
Fitzgerald, TJ ;
Urie, MM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 46 (01) :187-194