The reliability of continuous measurement of mixed venous oxygen saturation during exercise in patients with chronic heart failure

被引:2
作者
Sleutjes, Boudewijn T. H. M. [2 ]
Kemps, Hareld M. C. [1 ]
Thijssen, Eric J. M. [3 ]
van de Vosse, Frans N. [2 ]
Schep, Goof [1 ]
Peters, Chris H. [4 ]
Wijn, Pieter F. F. [4 ,5 ]
机构
[1] Maxima Med Ctr, Dept Sports Med, NL-5500 MB Veldhoven, Netherlands
[2] Eindhoven Univ Technol, Dept Biomed Engn, NL-5600 MB Eindhoven, Netherlands
[3] Maxima Med Ctr, Dept Cardiol, NL-5500 MB Veldhoven, Netherlands
[4] Maxima Med Ctr, Dept Clin Phys, NL-5500 MB Veldhoven, Netherlands
[5] Eindhoven Univ Technol, Dept Appl Phys, NL-5600 MB Eindhoven, Netherlands
关键词
exercise testing; heart failure; mixed venous oxygen saturation; pulmonary artery catheter;
D O I
10.1007/s00421-007-0597-2
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Continuous assessment of mixed venous oxygen saturation (cSvO(2)) during exercise using a fiber optic pulmonary artery catheter can provide valuable information on the physiological determinants of the exercise capacity in patients with chronic heart failure (CHF). Since its accuracy is not well established during exercise, this study evaluated the reliability of a fiber optic pulmonary artery catheter for measuring SVO2 during exercise in CHF patients. Ten patients with stable CHF performed steady-state exercise tests at 30 and 80% of the ventilatory threshold and consequently a symptom-limited incremental exercise test. During the tests, SvO(2) was monitored continuously using a fiber optic pulmonary artery catheter (CCOmbo, Edwards Lifesciences, Irvine, CA, USA) and by oximetric analysis of mixed venous blood samples obtained at rest (n = 26), steady state (n = 17) and peak exercise (n = 8). There was a significant correlation between oximetrically determined SvO(2) and cSvO(2) values (r = 0.97). The bias between both methods was 0.6% with limits of agreement from -8 to 9%. The limits of agreement for SVO2 values 30% (n = 16) were slightly wider than for SVO2 values >30% (n = 35) (from -10 to 12% and from -7 to 8%, respectively). In conclusion, continuous measurement of SvO(2) during exercise using a fiber optic pulmonary catheter is reliable in patients with CHF, with somewhat less accurate measurements Of SvO(2) below 30%.
引用
收藏
页码:493 / 496
页数:4
相关论文
共 16 条
[1]   The acute effects of resistance exercise on the main determinants of blood rheology [J].
Ahmadizad, S ;
El-Sayed, MS .
JOURNAL OF SPORTS SCIENCES, 2005, 23 (03) :243-249
[2]  
BAELE PL, 1982, ANESTH ANALG, V61, P513
[3]   A NEW METHOD FOR DETECTING ANAEROBIC THRESHOLD BY GAS-EXCHANGE [J].
BEAVER, WL ;
WASSERMAN, K ;
WHIPP, BJ .
JOURNAL OF APPLIED PHYSIOLOGY, 1986, 60 (06) :2020-2027
[4]  
Bjornstad H, 2001, EUR HEART J, V22, P37
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   Evaluation of a continuous cardiac output and mixed venous oxygen saturation catheter in critically ill surgical patients [J].
Burchell, SA ;
Yu, MH ;
Takiguchi, SA ;
Ohta, RM ;
Myers, SA .
CRITICAL CARE MEDICINE, 1997, 25 (03) :388-391
[7]   CLINICAL-EXPERIENCE WITH CONTINUOUS MONITORING OF MIXED VENOUS OXYGEN-SATURATION IN RESPIRATORY-FAILURE [J].
FAHEY, PJ ;
HARRIS, K ;
VANDERWARF, C .
CHEST, 1984, 86 (05) :748-752
[8]   ACCURACY OF FIBEROPTIC CENTRAL VENOUS SATURATION CATHETER BELOW 50-PERCENT [J].
FLETCHER, EC ;
MILLER, T ;
THORNBY, JI .
JOURNAL OF APPLIED PHYSIOLOGY, 1988, 64 (05) :2220-2223
[9]   Kinetics of oxygen uptake at onset of exercise related to cardiac output, but not to arteriovenous oxygen difference in patients with chronic heart failure [J].
Matsumoto, A ;
Itoh, H ;
Yokoyama, I ;
Aoyagi, T ;
Sugiura, S ;
Hirata, Y ;
Kato, M ;
Momomura, S .
AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (11) :1573-+
[10]   CONTINUOUS FICK CARDIAC-OUTPUT MEASUREMENT DURING EXERCISE BY MONITORING OF MIXED VENOUS OXYGEN-SATURATION AND OXYGEN-UPTAKE [J].
NAKANISHI, N ;
YOSHIOKA, T ;
OKANO, Y ;
NISHIMURA, T .
CHEST, 1993, 104 (02) :419-426