Luminescent probes for detection and imaging of hydrogen peroxide

被引:118
作者
Schaeferling, Michael [1 ]
Groegel, Dominik B. M. [1 ]
Schreml, Stephan [2 ]
机构
[1] Univ Regensburg, Inst Analyt Chem Chemo & Biosensors, D-93040 Regensburg, Germany
[2] Univ Hosp Regensburg, Dept Dermatol, Regensburg, Germany
关键词
Hydrogen peroxide; Reactive oxygen species; Fluorescent probes; Fluorescence imaging; Cell signaling; PHOTOINDUCED ELECTRON-TRANSFER; FLUORESCENT-PROBES; GROWTH-FACTOR; NITRIC-OXIDE; FLUOROMETRIC-DETERMINATION; OPTICAL-DETECTION; OXIDATIVE STRESS; NADPH OXIDASE; WOUND REPAIR; SENSORS;
D O I
10.1007/s00604-011-0606-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The relevance of hydrogen peroxide (H2O2) in biological processes has been underestimated for a long time. In recent years, various reports showed that H2O2 not only acts as a cytotoxic compound appearing in the course of oxidative stress, but also functions as an important signaling molecule. Fluorescent probes (or indicators) and nanoparticles that respond selectively to hydrogen peroxide can be applied for intracellular measurements or in vivo imaging, and are superior to electrochemical methods, e.g. in terms of spatial resolution. In contrast to previous reviews that concentrated on the adoption of different probes for certain applications, this survey highlights the basic principles of different probes in terms of their chemical design, structures and functionalities. Thus, the probes are classified according to the underlying reaction mechanism: oxidation, hydrolysis, photoinduced electron transfer, and lanthanide complexation. Other assays are based on fluorescent proteins and nanoparticles, and chemi- or bioluminescent reagents. We confine this review to probes that display a more or less distinct selectivity to hydrogen peroxide. Indicators responding to reactive oxygen species (ROS) in general, or to particular other ROS, are not covered. Finally, we briefly discuss future trends and perspectives of these luminescent reporters in biomedical research and imaging.
引用
收藏
页码:1 / 18
页数:18
相关论文
共 129 条
[1]  
AKASAKA K, 1987, ANAL LETT, V20, P731
[2]   A FRET-based approach to ratiometric fluorescence detection of hydrogen peroxide [J].
Albers, Aaron E. ;
Okreglak, Voytek S. ;
Chang, Christopher J. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (30) :9640-9641
[3]  
[Anonymous], ANGEW CHEM
[4]  
[Anonymous], Molecular Probes Handbook, A Guide to Fluorescent Probes and Labeling Technologies, V11th
[5]   Supramolecular analytical chemistry [J].
Anslyn, Eric V. .
JOURNAL OF ORGANIC CHEMISTRY, 2007, 72 (03) :687-699
[6]   A peroxyoxalate chemiluminescence-based assay for the evaluation of hydrogen peroxide scavenging activity employing 9,10-diphenylanthracene as the fluorophore [J].
Arnous, A ;
Petrakis, C ;
Makris, DP ;
Kefalas, P .
JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 2002, 48 (03) :171-177
[7]   Epidermal growth factor (EGF)-induced generation of hydrogen peroxide - Role in EGF receptor-mediated tyrosine phosphorylation [J].
Bae, YS ;
Kang, SW ;
Seo, MS ;
Baines, IC ;
Tekle, E ;
Chock, PB ;
Rhee, SG .
JOURNAL OF BIOLOGICAL CHEMISTRY, 1997, 272 (01) :217-221
[8]   The free radical theory of aging matures [J].
Beckman, KB ;
Ames, BN .
PHYSIOLOGICAL REVIEWS, 1998, 78 (02) :547-581
[9]   The efficient intramolecular sensitisation of terbium(III) and europium(III) by benzophenone-containing ligands [J].
Beeby, A ;
Bushby, LM ;
Maffeo, D ;
Williams, JAG .
JOURNAL OF THE CHEMICAL SOCIETY-PERKIN TRANSACTIONS 2, 2000, (07) :1281-1283
[10]   Non-radiative deactivation of the excited states of europium, terbium and ytterbium complexes by proximate energy-matched OH, NH and CH oscillators: an improved luminescence method for establishing solution hydration states [J].
Beeby, A ;
Clarkson, IM ;
Dickins, RS ;
Faulkner, S ;
Parker, D ;
Royle, L ;
de Sousa, AS ;
Williams, JAG ;
Woods, M .
JOURNAL OF THE CHEMICAL SOCIETY-PERKIN TRANSACTIONS 2, 1999, (03) :493-503