Non-Invasive Functional Evaluation of the Human Spinal Cord by Assessing the Peri-Spinal Neurovascular Network With Near Infrared Spectroscopy

被引:4
|
作者
Valenzuela, Felipe [1 ]
Rana, Mohit [2 ]
Sitaram, Ranganatha [3 ]
Uribe, Sergio [4 ]
Eblen-Zajjur, Antonio [5 ]
机构
[1] Pontificia Univ Catolica Chile, Ctr Biomed Imaging, Santiago 6513677, Chile
[2] Pontificia Univ Catolica Chile, Sch Med, Dept Psychiat, Div Neurosci, Santiago 6513677, Chile
[3] St Jude Childrens Res Hosp, Multimodal Funct Brain Imaging & Neurorehabil Hub, Diagnost Imaging Dept, Memphis, TN 38105 USA
[4] Pontificia Univ Catolica Chile, Sch Med, Millenium Nucleus Cardiovasc Magnet Resonance & R, Santiago 6513677, Chile
[5] Univ Diego Portales, Fac Med, Translat Neurosci Lab, Santiago 8370109, Chile
基金
芬兰科学院;
关键词
Spinal cord; Magnetic resonance imaging; Signal to noise ratio; Protocols; Optical filters; Skin; Monitoring; fNIRS; functional test; nerve stimulation; neuro-vascular coupling; neuro-vascular response; spinal cord; DORSAL-HORN; GAP-JUNCTIONS; BLOOD-FLOW; STIMULATION; MODULATION; NEURONS;
D O I
10.1109/TNSRE.2021.3123587
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Current medical care lacks an effective functional evaluation for the spinal cord. Magnetic resonance imaging and computed tomography mainly provide structural information of the spinal cord, while spinal somatosensory evoked potentials are limited by a low signal to noise ratio. We developed a non-invasive approach based on near-infrared spectroscopy in dual-wavelength (760 and 850 nm for deoxy- or oxyhemoglobin respectively) to record the neurovascular response (NVR) of the peri-spinal vascular network at the 7th cervical and 10th thoracic vertebral levels of the spinal cord, triggered by unilateral median nerve electrical stimulation (square pulse, 5-10 mA, 5 ms, 1 pulse every 4 minutes) at the wrist. Amplitude, rise-time, and duration of NVR were characterized in 20 healthy participants. A single, painless stimulus was able to elicit a high signal-to-noise ratio and multi-segmental NVR (mainly from Oxyhemoglobin) with a fast rise time of 6.18 [4.4-10.4] seconds (median [Percentile 25-75]) followed by a slow decay phase for about 30 seconds toward the baseline. Cervical NVR was earlier and larger than thoracic and no left/right asymmetry was detected. Stimulus intensity/NVR amplitude fitted to a 2nd order function. The characterization and feasibility of the peri-spinal NVR strongly support the potential clinical applications for a functional assessment of spinal cord lesions.
引用
收藏
页码:2312 / 2321
页数:10
相关论文
共 50 条
  • [41] Non-invasive measurement of intraocular pressure by near-infrared spectroscopy
    Weissbrodt, D
    Müeller, R
    Backhaus, J
    Jonas, JB
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 140 (02) : 307 - 308
  • [42] Non-invasive confirmation of the identity of tablets by near-infrared spectroscopy
    Ulmschneider, M
    Pénigault, E
    ANALUSIS, 2000, 28 (04) : 336 - 346
  • [43] Transcutaneous Spinal Cord Stimulation: Advances in an Emerging Non-Invasive Strategy for Neuromodulation
    Hofstoetter, Ursula S.
    Minassian, Karen
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (13)
  • [44] Non-invasive blood glucose sensing on human body with near-infrared reflection spectroscopy
    Huang Zhen-hao
    Hao Chang-ning
    Zhang Lin-lin
    Huang Yan-chao
    Shi Yi-qin
    Jiang Geng-ru
    Duan Jun-li
    INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2011: ADVANCES IN INFRARED IMAGING AND APPLICATIONS, 2011, 8193
  • [45] Non-invasive detection of brain microvascular dysfunction by near infrared spectroscopy
    Vayman, V.
    Martsiano, S.
    Weinstein, M.
    Nachum-Biala, Y.
    Troen, A.
    JOURNAL OF MOLECULAR NEUROSCIENCE, 2013, 51 : S126 - S127
  • [46] Non-invasive urodynamics and detrusor oxygenation using near infrared spectroscopy
    Stothers, L
    Macnab, A
    Gagnon, R
    JOURNAL OF UROLOGY, 2005, 173 (04): : 354 - 354
  • [47] Near infrared spectroscopy as a non-invasive assessment of cortical abnormality in migraine?
    Griffin, Murray
    Prior, Duncan
    Cooper, Chris E.
    Wilkins, Arnold J.
    Elwelll, Clare E.
    OXYGEN TRANSPORT TO TISSUE XXVII, 2006, 578 : 203 - 208
  • [48] A novel, non-invasive measure of bladder function in spinal cord injured rats
    Fedulov, V
    Duel, BP
    Cloutier, F
    Huynh, DH
    Bernal, GM
    Keirstead, HS
    JOURNAL OF NEUROTRAUMA, 2003, 20 (10) : 1084 - 1084
  • [49] Non-Invasive Spinal Cord Stimulation for Motor Rehabilitation of Patients with Spinal Muscular Atrophy Treated with Orphan Drugs
    Novikov, Anton
    Maldova, Maria
    Shamantseva, Natalia
    Shalmiev, Ivan
    Shoshina, Elena
    Epoyan, Natalia
    Krutikova, Natalia
    Moshonkina, Tatiana
    BIOMEDICINES, 2024, 12 (06)
  • [50] Near Infrared Spectroscopy (NIRs) Applications in Medical: Non-invasive and Invasive Leukemia Screening
    Ismail, Ruhaizan
    Rahim, Herlina Abdul
    2016 IEEE 12TH INTERNATIONAL COLLOQUIUM ON SIGNAL PROCESSING & ITS APPLICATIONS (CSPA), 2016, : 305 - 310