On the measurement of positron emitters with Ge detectors

被引:4
作者
Peyres, Virginia [1 ]
Garcia-Torano, Eduardo [1 ]
机构
[1] Lab Metrol Radiac Ionizantes, Madrid 28040, Spain
关键词
Gamma spectrometry; Positron emitters; Standardization; Calibration; EFFICIENCY;
D O I
10.1016/j.nima.2011.02.035
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper discusses the problems related to the measurement of positron emitters with germanium detectors. Five positron emitters with important applications in nuclear medicine (Na-22, F-18, C-11, N-13 and Ga-68) have been studied. Measurements and Monte Carlo simulations have been used to determine the optimal conditions of measurement in gamma-ray spectrometry systems. The results obtained indicate that adding adequate absorbers, detection efficiencies are close to those of gamma emitters of similar energy measured in the same conditions, which allows a rapid calibration of a Ge-based spectrometry system. More accurate results are also presented using a detailed Monte Carlo simulation. Comparison to experimental data shows a good agreement. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:100 / 104
页数:5
相关论文
共 50 条
[21]   A new and general efficiency calibration methodology for Ge detectors using LabSOCS [J].
Barba-Lobo, A. .
RADIATION MEASUREMENTS, 2025, 181
[22]   Personal dosimetry for positron emitters, and occupational exposures from clinical use of gallium-68 [J].
Eakins, J. ;
Hager, L. ;
O'Connor, U. ;
Cooke, J. ;
O'Reilly, G. ;
Walsh, C. ;
Willson, T. .
JOURNAL OF RADIOLOGICAL PROTECTION, 2022, 42 (03)
[23]   Novel Point-Like 68Ge/68Ga Radioactive Source With Spherical Positron Absorber [J].
Hasegawa, Tomoyuki ;
Oda, Keiichi ;
Yamada, Takahiro ;
Matsumoto, Mikio ;
Sato, Yasushi ;
Murayama, Hideo ;
Takei, Hideyuki .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (01) :24-29
[24]   Expanding PET-applications in life sciences with positron-emitters beyond fluorine-18 [J].
Coenen, Heinz H. ;
Ermert, Johannes .
NUCLEAR MEDICINE AND BIOLOGY, 2021, 92 :241-269
[25]   Comparison of Luminance Measurement based on Illuminance and Luminance Detectors [J].
Fiorentin, Pietro ;
Scroccaro, Alessandro .
I2MTC: 2009 IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-3, 2009, :785-789
[26]   Calibration of neutron detectors at ASDEX Upgrade, measurement and model [J].
Koleva, Monika ;
Tardini, Giovanni ;
Zohm, Hartmut ;
Akaslompolo, Simppa ;
Leppanen, Jaakko .
FUSION ENGINEERING AND DESIGN, 2021, 170
[27]   Activity measurement of 68Ge-68Ga by use of 4π(β+ +γ) integral counting method [J].
Yamada, T. ;
Ishizu, H. ;
Kawada, Y. ;
Yunoki, A. ;
Yano, S. .
APPLIED RADIATION AND ISOTOPES, 2016, 109 :325-329
[28]   Measurement of cross sections of threshold detectors with spectrum average technique [J].
Agus, Y ;
Çelenk, I ;
Özmen, A .
RADIOCHIMICA ACTA, 2004, 92 (02) :63-68
[29]   Use of short-lived positron emitters for in-beam and real-time β+ range monitoring in proton therapy [J].
Bongrand, A. ;
Busato, E. ;
Force, P. ;
Martin, F. ;
Montarou, G. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 69 :248-255
[30]   Comparison of sliced and whole lung sets for the LLNL and JAERI torso phantoms using Ge detectors [J].
Kramer, GH ;
Hauck, BM ;
Lee, TY ;
Chang, SY .
HEALTH PHYSICS, 1999, 76 (05) :547-552