The minimally invasive surgical suite enters the 21st century -: A discussion of critical design elements

被引:39
作者
Herron, DM
Gagner, M
Kenyon, TL
Swanström, LL
机构
[1] Mt Sinai Med Ctr, Dept Surg, Div Laparoscop Surg, New York, NY 10029 USA
[2] Legacy Hlth Syst, Div Minamally Invas Surg, Portland, OR 97227 USA
来源
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES | 2001年 / 15卷 / 04期
关键词
operating room; minimally invasive surgery; laparoscopy; endoscopy; ergonomics;
D O I
10.1007/s004640080134
中图分类号
R61 [外科手术学];
学科分类号
摘要
Most minimally invasive surgical procedures are now performed in operating rooms that were originally designed for traditional open surgery, Laparoscopic instrumentation such as insufflators, light sources, and camera control units must be placed on one or more equipment carts. After the cart has been moved into place, insufflation tubing, video cables, light cords, cautery lines, and foot controls must be positioned and connected, This cart-based paradigm restricts the ergonomic configuration of the operating room and creates potential mechanical, electrical, and biological hazards to the patient and operating room staff In order to decrease clutter, ease personnel movement, improve ergonomics, maintain the sterile field, and facilitate the use of advanced imaging, communication, and display devices, an appropriately designed operating environment is essential. Herein we detail both the theoretical and practical aspects of die design and describe the implementation and utilization of such a suite in our hospital. These design elements may prove to be critical to the next generation of minimally invasive surgical suites and will facilitate future advanced laparoscopic procedures.
引用
收藏
页码:415 / 422
页数:8
相关论文
共 15 条
[1]  
Alarcon A, 1996, SURG ENDOSC, V10, P916
[2]   A comparison of surgeons' posture during laparoscopic and open surgical procedures [J].
Berguer, R ;
Rab, GT ;
AbuGhaida, H ;
Alarcon, A ;
Chung, J .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1997, 11 (02) :139-142
[3]   Surgical technology and the ergonomics of laparoscopic instruments [J].
Berguer, R .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1998, 12 (05) :458-462
[4]   EVALUATING THE HUMAN ENGINEERING OF MICROPROCESSOR-CONTROLLED OPERATING-ROOM DEVICES [J].
COOK, RI ;
POTTER, SS ;
WOODS, DD ;
MCDONALD, JS .
JOURNAL OF CLINICAL MONITORING, 1991, 7 (03) :217-226
[5]   Long distance telementoring - A novel tool for laparoscopy aboard the USS Abraham Lincoln [J].
Cubano, M ;
Poulose, BK ;
Talamini, MA ;
Stewart, R ;
Antosek, LE ;
Lentz, R ;
Nibe, R ;
Kutka, MF ;
Mendoza-Sagaon, M .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1999, 13 (07) :673-678
[6]  
Geis WP, 1996, SURG ENDOSC-ULTRAS, V10, P768
[7]   Task performance in endoscopic surgery is influenced by location of the image display [J].
Hanna, GB ;
Shimi, SM ;
Cuschieri, A .
ANNALS OF SURGERY, 1998, 227 (04) :481-484
[8]   The 3-D monitor and head-mounted display - A quantitative evaluation of advanced laparoscopic viewing technologies [J].
Herron, DM ;
Lantis, JC ;
Maykel, J ;
Basu, C ;
Schwaitzberg, SD .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 1999, 13 (08) :751-755
[9]   Lloyd-Davies position with Trendelenburg - A disaster waiting to happen? [J].
Horgan, AF ;
Geddes, S ;
Finlay, IG .
DISEASES OF THE COLON & RECTUM, 1999, 42 (07) :916-919
[10]   MIS instruments -: An experimental comparison of various ergonomic handles and their design [J].
Matern, U ;
Eichenlaub, M ;
Waller, P ;
Rückauer, KD .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1999, 13 (08) :756-762