Comparison of Horizontal Corneal Diameter Measurements Using Orbscan IIz, OPD Scan III, and IOLMaster 700

被引:5
作者
Cruz, Sebastian [1 ]
Valenzuela, Felipe [1 ,2 ]
Stoppel, Juan [1 ]
Maul, Eugenio [1 ]
Gibbons, Allister [3 ]
机构
[1] Univ Los Andes, Dept Ophthalmol, Fdn Oftalmol Los Andes, Santiago, Chile
[2] Clin Univ Los Andes, Dept Ophthalmol, Santiago, Chile
[3] Univ Miami, Miller Sch Med, Bascom Palmer Eye Inst, Miami, FL 33136 USA
来源
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE | 2021年 / 47卷 / 10期
关键词
Corneal diameter; White-to-white distance; Orbscan IIz; IOLMaster; 700; OPD scan III; WHITE-TO-WHITE; OPTICAL COHERENCE TOMOGRAPHY; ANTERIOR-CHAMBER DEPTH; INTRAOCULAR LENSES; TOPOGRAPHY; VAULT; ANGLE;
D O I
10.1097/ICL.0000000000000786
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare three automated devices for measuring the horizontal corneal diameter (white to white [WTW]). Methods: In 65 eyes of 38 patients, the WTW distance was measured independently by three examiners using the following techniques: Orbscan IIz tomography system (Bausch & Lomb), IOLMaster 700 (Carl Zeiss Meditec), and OPD Scan III (NIDEK). We tested for systematic differences in measurements and estimated the limits of agreement (LoA) using linear mixed-effects models. Results: The mean WTW distance was 11.8 +/- 0.40 mm with Orbscan IIz, 12.1 +/- 0.5 mm with IOLMaster 700 and 12.0 +/- 0.4 mm with OPD Scan III. The mean difference between IOLMaster 700 and Orbscan IIz was 0.33 (95% CI, 0.28 to 0.38; P<0.001), between OPD Scan III and Orbscan IIz was 0.24 mm (95% CI, 0.21 to 0.28; P<0.001), and between IOL Master 700 and OPD Scan III was 0.09 (95% CI, 0.05 to 0.12; P<0.001). The 95% LoA for Orbscan IIz versus IOLMaster 700 was -0.69 to 0.03 mm, Orbscan IIz versus OPD Scan III was -0.52 to -0.03 mm, and OPD versus IOLMaster 700 was -0.39 to 0.22 mm. Conclusions: The data suggest that these devices are not interchangeable for usual clinical practice. Adjustments based on mean differences were not enough to compensate for interinstrument discrepancy in WTW measurements.
引用
收藏
页码:533 / 538
页数:6
相关论文
共 24 条
[1]   Evaluation and comparison of the new swept source OCT-based IOLMaster 700 with the IOLMaster 500 [J].
Akman, Ahmet ;
Asena, Leyla ;
Gungor, Sirel Gur .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2016, 100 (09) :1201-1205
[2]   OPD-Scan III: a repeatability and inter-device agreement study of a multifunctional device in emmetropia, ametropia, and keratoconus [J].
Asgari, Soheila ;
Hashemi, Hassan ;
Jafarzadehpur, Ebrahim ;
Mohamadi, Alireza ;
Rezvan, Farhad ;
Fotouhi, Akbar .
INTERNATIONAL OPHTHALMOLOGY, 2016, 36 (05) :697-705
[3]   Comparison of manual and automated methods to determine horizontal corneal diameter [J].
Baumeister, M ;
Terzi, E ;
Ekici, Y ;
Kohnen, T .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (02) :374-380
[4]  
Cho Young Joo, 2018, Korean J Ophthalmol, V32, P257, DOI 10.3341/kjo.2017.0091
[5]   Improving accuracy of phakic intraocular lens sizing using high-frequency ultrasound biomicroscopy [J].
Dougherty, Paul J. ;
Rivera, Robert P. ;
Schneider, David ;
Lane, Stephen S. ;
Brown, David ;
Vukich, John .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (01) :13-18
[6]   Implantable Collamer Posterior Chamber Intraocular Lenses: A Review of Potential Complications [J].
Fernandes, Paulo ;
Gonzalez-Meijome, Jose M. ;
Madrid-Costa, David ;
Ferrer-Blasco, Teresa ;
Jorge, Jorge ;
Montes-Mico, Robert .
JOURNAL OF REFRACTIVE SURGERY, 2011, 27 (10) :765-776
[7]  
Ghoreishi M., 2014, J CLIN EXP OPHTHALMO, V5, P351
[8]   Late in-the-bag intraocular lens dislocation: Incidence, prevention, and management [J].
Gimbel, HV ;
Condon, GP ;
Kohnen, T ;
Olson, RJ ;
Halkiadakis, I .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (11) :2193-2204
[9]   Phakic intraocular lenses Part 1: Historical overview, current models, selection criteria, and surgical techniques [J].
Guell, Jose Luis ;
Morral, Merce ;
Kook, Daniel ;
Kohnen, Thomas .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (11) :1976-1993
[10]   Internal anterior chamber diameter using optical coherence tomography compared with white-to-white distances using automated measurements [J].
Kohnen, Thomas ;
Thomala, Martin Christian ;
Cichocki, Magdalena ;
Strenger, Anja .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (11) :1809-1813