SPECT low-field MRI system for small-animal imaging

被引:48
作者
Goetz, Christian [1 ]
Breton, Elodie [1 ]
Choquet, Philippe [1 ]
Israel-Jost, Vincent [2 ]
Constantinesco, Andre [1 ]
机构
[1] Hop Hautepierre, Serv Biophys & Med Nucl, Strasbourg, France
[2] ENST GET TSI, Paris, France
关键词
small animals; dual modality; SPECT; MRI; molecular imaging;
D O I
10.2967/jnumed.107.044313
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Localization of regions with increased uptake of radiotracer in small-animal SPECT is greatly facilitated when using coregistration with anatomic images of the same animal. As MRI has several advantages compared with CT (soft-tissue contrast and lack of ionizing radiation) we developed a SPECT/low-field MRI hybrid device for small-animal imaging. Methods: A small-animal single-pinhole gamma-camera (pinhole, 1.5 mm in diameter and 12 cm in focal length) adjacent to a dedicated low-field (0.1 T) small MR imager (imaging volume, 10 x 10 x 6 cm(3)) was used. The animal was placed in a warmed nonmagnetic polymethyl methacrylate imaging cell for MR acquisition, which was followed immediately by SPECT after translation of the imaging cell from one modality to the other. 3-Dimensional T1-weighted sequences were used for MRI. Phantom studies enabled verification of a low attenuation (10%) for Tc-99m and (TI)-T-201 and a very slight increase in Compton scattering due to the radiofrequency coil and polymethyl methacrylate imaging cell. Results: SPECT/ MRI data acquisition and image coregistration of selected examples using different radiotracers for lungs, kidneys, and brain were obtained in 3 nude mice with isotropic spatial resolutions of 0.5 x 0.5 x 0.5 mm(3) for MRI and 1 x 1 x 1 mm(3) for SPECT. The total acquisition time for combined SPECT and MRI lasted 1 h 45 min. Conclusion: A low-magnetic-field strength of 0.1 T is a simple and useful solution for a small-animal dual-imaging device combining pinhole SPECT with the adjacent MR imager.
引用
收藏
页码:88 / 93
页数:6
相关论文
共 33 条
[1]  
Acton PD, 2006, J NUCL MED, V47, p52N
[2]   DEDICATED LOW-FIELD MRI - A PROMISING LOW-COST TECHNIQUE [J].
ARBOGASTRAVIER, S ;
XU, F ;
CHOQUET, P ;
BRUNOT, B ;
CONSTANTINESCO, A .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1995, 33 (05) :735-739
[3]  
Beekman FJ, 2005, J NUCL MED, V46, P1194
[4]   Multi-modality imaging on track [J].
Beekman, Freek ;
Hutton, Brian F. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 (09) :1410-1414
[5]   MR microscopy and high resolution'small animal MRI: applications in neuroscience research [J].
Benveniste, H ;
Blackband, S .
PROGRESS IN NEUROBIOLOGY, 2002, 67 (05) :393-420
[6]   Imaging of striatal dopamine transporters in rat brain with single pinhole SPECT and co-aligned MRI is highly reproducible [J].
Booij, J ;
de Bruin, K ;
de Win, MML ;
Lavini, C ;
den Heeten, GJ ;
Habraken, JBA .
NUCLEAR MEDICINE AND BIOLOGY, 2003, 30 (06) :643-649
[7]  
BOURNE L, 1996, 4 SCI M APR 27 MAY 3
[8]   Dual SPECT/MR imaging in small animal [J].
Breton, E. ;
Choquet, P. ;
Goetz, C. ;
Kintz, J. ;
Erbs, P. ;
Rooke, R. ;
Constantinesco, A. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 571 (1-2) :446-448
[9]  
Catana C, 2006, J NUCL MED, V47, P1968
[10]   A method of image registration for small animal, multi-modality imaging [J].
Chow, PL ;
Stout, DB ;
Komisopoulou, E ;
Chatziioannou, AF .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (02) :379-390