Gas flow and particle deposition in the hot gas filter vessel at the Tidd 70 MWE PFBC demonstration power plant

被引:21
作者
Ahmadi, G [1 ]
Smith, DH
机构
[1] Clarkson Univ, Dept Mech & Aeronaut Engn, Potsdam, NY 13699 USA
[2] US DOE, Fed Energy Technol Ctr, Morgantown, WV 26507 USA
关键词
D O I
10.1080/02786829808965564
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Advanced hot-gas filtration systems for clean coal technologies have attracted considerable attention in recent years. The Tidd hot-gas filtration system mas the first demonstration unit in the United States. The system was operational for about four years (1990-1994) and has provided considerable engineering information concerning the operation of the demonstration-scale hot-gas particle filtration system. The present work describes a computer simulation study of gas how and particle transport and deposition in the Tidd filter vessel, The FLUENT(TM) code is used for evaluating the gas mean velocity, mean pressure, and the state of turbulence in the filter vessel. The three tiers with a total of 384 filters are modeled as three effective cylindrical filters. The particle equation of motion that includes the nonlinear drag and the gravity is used, The particle deposition patterns are evaluated, and the effect of particle size is studied. The results show that, for a clean filter system, the rate of deposition on different tiers depends on particle size, This could lead to nonuniform composition and thickness of the cakes that form on the candle filters in different tiers. AEROSOL SCIENCE AND TECHNOLOGY 29:206-223 (1998) (C) 1998 American Association for Aerosol Research.
引用
收藏
页码:206 / 223
页数:18
相关论文
共 35 条
[1]   Particle transport and deposition in a hot-gas cleanup pilot plant [J].
Ahmadi, G ;
Smith, DH .
AEROSOL SCIENCE AND TECHNOLOGY, 1998, 29 (03) :183-205
[2]  
AHMADI G, 1997, P 2 INT S SCAL MOD L, P337
[3]  
CHIANG TK, 1996, COMMUNICATION
[4]   SUB LAYER MODEL FOR DEPOSITION OF PARTICLES FROM A TURBULENT-FLOW [J].
CLEAVER, JW ;
YATES, B .
CHEMICAL ENGINEERING SCIENCE, 1975, 30 (08) :983-992
[5]  
Clift R., 1993, GAS CLEANING HIGH TE
[6]  
DENNIS RA, 1997, COMMUNICATION
[7]   A SUBLAYER MODEL FOR TURBULENT DEPOSITION OF PARTICLES IN VERTICAL DUCTS WITH SMOOTH AND ROUGH SURFACES [J].
FAN, FG ;
AHMADI, G .
JOURNAL OF AEROSOL SCIENCE, 1993, 24 (01) :45-64
[8]  
*FLUENT INC, 1994, FLUENT US GUID VERS
[9]  
Friedlander S.K., 1977, SMOKES DUST HAZE
[10]   DEPOSITION OF SUSPENDED PARTICLES FROM TURBULENT GAS STREAMS [J].
FRIEDLANDER, SK ;
JOHNSTONE, HF .
INDUSTRIAL AND ENGINEERING CHEMISTRY, 1957, 49 (07) :1151-1156