Prone Positioning With Deep Inspiration Breath Hold for Left Breast Radiotherapy

被引:5
|
作者
Goyal, Uma [1 ]
Saboda, Kathylynn [2 ]
Roe, Denise [2 ]
Gonzalez, Victor J. [1 ]
机构
[1] Univ Arizona, Dept Radiat Oncol, Tucson, AZ 85721 USA
[2] Univ Arizona, Dept Epidemiol & Biostat, Canc Ctr, Tucson, AZ USA
关键词
Breast cancer; Cardiac dose; Radiation; RADIATION-THERAPY; CONSERVING THERAPY; CANCER PATIENTS; HEART; IRRADIATION; MASTECTOMY; PATIENT; WOMEN; RISK; LUNG;
D O I
10.1016/j.clbc.2020.11.004
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Outcomes for early-stage breast cancer are improving. We investigated the combination of prone position and deep inspiration breath-hold to decrease cardiac doses for left-sided breast radiotherapy. Fifteen patients were enrolled. The average mean heart dose was significantly reduced with prone breath-hold compared with prone free breathing. Breath-hold may provide additional cardiac dose reduction with prone left-breast radiotherapy. Background: With advances in treatment, outcomes for early-stage breast cancer are improving. We investigated the combination of prone position and deep inspiration breath hold to decrease cardiac doses for left-sided breast radiotherapy. Material and Methods: Fifteen patients with left-sided breast cancer were enrolled on a single-institution prospective study. Each patient underwent 2 prone positioned computed tomography simulation scans utilizing free breathing and breath-hold. Separate treatment plans for each computed tomography simulation scan were created using tangential fields, and heart and left lung doses were compared between free breathing and breath-hold plans. The technique with the lower mean dose for the heart was used for treatment. All patients were treated with a hypofractionated regimen of 40 to 42 Gy in 15 to 16 fractions, followed by a lumpectomy cavity boost of 10 Gy in 5 fractions when indicated. Wilcoxon paired signed rank tests and paired t tests were performed for statistical analysis of dosimetric endpoints. Results: The median age of our patients was 58 years (range, 40-72 years). One patient was not able to tolerate prone positioning at simulation, leaving 14 patients with evaluable paired scans. The average mean heart dose with free breathing and with breath-hold was 0.93 Gy and 0.72 Gy, respectively (P=.0063). The average max heart dose with free breathing and with breath-hold was 15.70 Gy and 7.19 Gy, respectively (P=.001). The average mean left lung dose with free breathing and with breath-hold was 0.65 Gy and 0.88 Gy, respectively (P=.011). Conclusions: Our results indicate that breath-hold using the real-time position management system may provide additional cardiac dose reduction in patients receiving prone left-breast radiotherapy treated with tangential fields. (C) 2020 Elsevier Inc. All rights reserved.
引用
收藏
页码:E295 / E301
页数:7
相关论文
共 50 条
  • [31] Heart dose reduction by prone deep inspiration breath hold in left-sided breast irradiation
    Mulliez, Thomas
    Veldeman, Liv
    Speleers, Bruno
    Mahjoubi, Khalil
    Remouchamps, Vincent
    Van Greveling, Annick
    Gilsoul, Monique
    Berwouts, Dieter
    Lievens, Yolande
    Van den Broecke, Rudy
    De Neve, Wilfried
    RADIOTHERAPY AND ONCOLOGY, 2015, 114 (01) : 79 - 84
  • [32] Surface guided ring gantry radiotherapy in deep inspiration breath hold for breast cancer patients
    Kadhim, Mustafa
    Haraldsson, Andre
    Kugele, Malin
    Enocson, Hedda
    Back, Sven
    Ceberg, Sofie
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (10):
  • [33] Impact of deep inspiration breath hold, surface-guided radiotherapy, and daily CBCT on the organs at risk in breast cancer radiotherapy
    Rudat, Volker
    Zhao, Ruping
    Wang, Bin
    Zhang, Lihua
    Shi, Yanyan
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [34] Investigation of cardiac and pulmonar doses in patients with left sided breast cancer treated by radiotherapy with deep inspiration breath hold technique
    Parlar, S.
    Var, G.
    Cosar, R.
    Dogan, M.
    Ozguven, Y.
    Nurlu, D.
    CemUzal, M.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2022, 20 (02): : 369 - 375
  • [35] Impact of deep inspiration breath hold irradiation on dose reduction to the heart and left coronary artery in breast cancer
    Winczura, Piotr
    Wejs-Maternik, Julianna
    Blukis, Andrzej
    Antonowicz-Szydlowska, Monika
    Urbanowicz, Patrycja
    Rakowiecka, Agnieszka
    Urbanowicz, Marcin
    Pepa, Matteo
    Dicuonzo, Samantha
    Jereczek-Fossa, Barbara A.
    Badzio, Andrzej
    ONCOLOGY IN CLINICAL PRACTICE, 2025, 21 (01): : 1 - 7
  • [36] The implementation of RapidPlan in predicting deep inspiration breath-hold candidates with left-sided breast cancer
    Rice, Aubrie
    Zoller, Ian
    Kocos, Kevin
    Weller, Dannyl
    DiCostanzo, Dominic
    Hunzeker, Ashley
    Lenards, Nishele
    MEDICAL DOSIMETRY, 2019, 44 (03) : 210 - 218
  • [37] Dose reduction to organs at risk with deep-inspiration breath-hold during right breast radiotherapy: a treatment planning study
    Pandeli, Chloe
    Smyth, Lloyd M. L.
    David, Steven
    See, Andrew W.
    RADIATION ONCOLOGY, 2019, 14 (01)
  • [38] Anatomical Predictors of Dosimetric Advantages for Deep-inspiration-breath-hold 3D-conformal Radiotherapy Among Women With Left Breast Cancer
    Ferini, Gianluca
    Molino, Laura
    Tripoli, Antonella
    Valenti, Vito
    Illari, Salvatore Ivan
    Marchese, Valentina Anna
    Cravagno, Irene Rita
    Borzi, Giuseppina Rita
    ANTICANCER RESEARCH, 2021, 41 (03) : 1529 - 1538
  • [39] The benefits evaluation of abdominal deep inspiration breath hold based on knowledge-based radiotherapy treatment planning for left-sided breast cancer
    Xu, Jiaqi
    Wang, Jiazhou
    Zhao, Feng
    Hu, Weigang
    Yao, Guorong
    Lu, Zhongjie
    Yan, Senxiang
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (10): : 89 - 96
  • [40] Monitoring deep inspiration breath hold for left-sided localized breast cancer radiotherapy with an in-house developed laser distance meter system
    Jensen, Christer A.
    Abramova, Tatiana
    Frengen, Jomar
    Lund, Jo-Asmund
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (05): : 117 - 123