Evaluation of the Dosimetric Parameters for 125I Brachytherapy Determined in Prostate Medium using CT Images

被引:7
作者
Hanada, Takashi [1 ,2 ,3 ]
Yorozu, Atsunori [1 ]
Ohashi, Toshio [3 ]
Shigematsu, Naoyuki [3 ]
Maruyama, Koichi [2 ]
机构
[1] Natl Hosp Org, Tokyo Med Ctr, Dept Radiol, Meguro Ku, Tokyo 1528902, Japan
[2] Kitasato Univ, Grad Sch Med Sci, Kanagawa 2288555, Japan
[3] Keio Univ, Sch Med, Dept Radiol, Shinjuku Ku, Tokyo 1608582, Japan
关键词
Brachytherapy; Iodine-125; Monte Carlo simulation; Prostate carcinoma; Dosimetry; MONTE-CARLO; INTERSTITIAL BRACHYTHERAPY; INTERSEED ATTENUATION; DOSE-RATE; DISTRIBUTIONS;
D O I
10.1269/jrr.10027
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
In the present study, the prostate medium determined from the CT images of 149 patients was developed. The dosimetric parameters such as A, g(L)(r) and F(r, theta) used in TG-43U1-based calculation for an iodine-125 (I-125) brachytherapy-source were examined using Monte Carlo code Geant4. Clinical dosimetry parameters such as the D-90 were evaluated among a subgroup of 50 randomly selected patients who had been treated with permanent brachytherapy between January 2008 and December 2008 at the Tokyo Medical Center. The results show a slight difference in the dose rate constant A (within 1.0%). The radial dose function g(L)(r) exhibits a prominent difference in the region over 3 cm, and this difference is maintained within 2.9% in the region close to the source. The calculated values of F(r, 0) for the prostate medium were similar to values for water (within 1%), except in the longitudinal axis. A comparison of D-90 values shows a systematic dose overestimation of 2.8 +/- 0.7 Gy in water, where the distribution of the differences can be seen with a spread of 1.8 +/- 0.3% compared to that in prostate medium. It was concluded that the introduction of any kind of tissue correction for the TG-43U1-based calculation was not necessary to allow for the differences in elemental compositions and densities between water and prostate medium. PACS number: 87.00.00; 87.55.dk; 87.55.K-; 87.56.B-
引用
收藏
页码:553 / 561
页数:9
相关论文
共 28 条
  • [1] GEANT4-a simulation toolkit
    Agostinelli, S
    Allison, J
    Amako, K
    Apostolakis, J
    Araujo, H
    Arce, P
    Asai, M
    Axen, D
    Banerjee, S
    Barrand, G
    Behner, F
    Bellagamba, L
    Boudreau, J
    Broglia, L
    Brunengo, A
    Burkhardt, H
    Chauvie, S
    Chuma, J
    Chytracek, R
    Cooperman, G
    Cosmo, G
    Degtyarenko, P
    Dell'Acqua, A
    Depaola, G
    Dietrich, D
    Enami, R
    Feliciello, A
    Ferguson, C
    Fesefeldt, H
    Folger, G
    Foppiano, F
    Forti, A
    Garelli, S
    Giani, S
    Giannitrapani, R
    Gibin, D
    Cadenas, JJG
    González, I
    Abril, GG
    Greeniaus, G
    Greiner, W
    Grichine, V
    Grossheim, A
    Guatelli, S
    Gumplinger, P
    Hamatsu, R
    Hashimoto, K
    Hasui, H
    Heikkinen, A
    Howard, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) : 250 - 303
  • [2] Postimplant dosimetry using a Monte Carlo dose calculation engine:: A new clinical standard
    Carrier, Jean-Francois
    D'Amours, Michel
    Verhaegen, Frank
    Reniers, Brigitte
    Martin, Andre-Guy
    Vigneault, Eric
    Beaulieu, Luc
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (04): : 1190 - 1198
  • [3] Impact of interseed attenuation and tissue composition for permanent prostate implants
    Carrier, JF
    Beaulieu, L
    Therriault-Proulx, F
    Roy, R
    [J]. MEDICAL PHYSICS, 2006, 33 (03) : 595 - 604
  • [4] Dosimetric effects of seed anisotropy and interseed attenuation for 103Pd and 125I prostate implants
    Chibani, O
    Williamson, JF
    Todor, D
    [J]. MEDICAL PHYSICS, 2005, 32 (08) : 2557 - 2566
  • [5] Investigation of the air kerma response of spherical ionization chambers for unfolded pulse height distributions of 60CO and 137Cs using the EGS4 Monte Carlo code
    Chun, Kook Jin
    Yoo, Gwang Ho
    [J]. JOURNAL OF RADIATION RESEARCH, 2007, 48 (05) : 385 - 395
  • [6] CIEZKI JP, 2004, INT J RADIAT ONCOL, V60, P1447
  • [7] CT-based dosimetry calculations for 125I prostate implants
    DeMarco, JJ
    Smathers, JB
    Burnison, CM
    Ncube, QK
    Solberg, TD
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (05): : 1347 - 1353
  • [8] Monte Carlo and experimental dosimetry of an 125I brachytherapy seed
    Dolan, James
    Li, Zuofeng
    Williamson, Jeffrey F.
    [J]. MEDICAL PHYSICS, 2006, 33 (12) : 4675 - 4684
  • [9] Bremsstrahlung and Photoneutron Leakage from Steel Shielding Board Impinged by 12-24 MeV Electrons Beams
    Fujita, Yukio
    Saitoh, Hidetoshi
    Myojoyama, Atsushi
    [J]. JOURNAL OF RADIATION RESEARCH, 2009, 50 (04) : 363 - 369
  • [10] Goldstone K., 1989, ICRU report 44, DOI DOI 10.1093/JICRU/OS23.1.REPORT44