Rapid, hand-held paper diagnostic for measuring Fibrinogen Concentration in blood

被引:7
作者
Bialkower, Marek [1 ,2 ]
McLiesh, Heather [1 ,2 ]
Manderson, Clare A. [1 ,2 ]
Tabor, Rico F. [3 ]
Garnier, Gil [1 ,2 ]
机构
[1] Monash Univ, BioPRIA, Clayton, Vic, Australia
[2] Monash Univ, Dept Chem Engn, Clayton, Vic, Australia
[3] Monash Univ, Sch Chem, Clayton, Vic 3800, Australia
基金
澳大利亚研究理事会;
关键词
Fibrinogen paper diagnostic; Paper test; Blood; Plasma; Transfusion; Bleeding; Haemorrhage; Coagulopathy; Fibrinogen concentration; TRAUMA-HEMORRHAGE; FACTOR-XIII; PLASMA; MANAGEMENT; TRANSFUSION; COAGULATION; REPLACEMENT; ACTIVATION; THROMBIN; HEPARIN;
D O I
10.1016/j.aca.2019.12.046
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Critical bleeding causes over 2 million deaths a year. Early hypofibrinogenemia is a strong predictor of mortality in critically bleeding patients. The early replenishment of fibrinogen can significantly improve outcomes. However, over replenishment can also be dangerous. Furthermore, there is no rapid, cheap, hand-held diagnostic that can aid critically bleeding patients in fibrinogen replacement therapy. In this study, we have developed a hand-held paper diagnostic that measures plasma fibrinogen concentrations. The diagnostic has the potential to be used as a point of care device both inside and outside of hospital settings. It can vastly reduce the time to treatment for fibrinogen replacement therapy. The diagnostic is a two-step process. First, thrombin and plasma are added onto horizontially-orientated paper strips where the fibrinogen is converted into fibrin, drastically increasing the plasma's hydrophobicity. Second, an aqueous blue dye is pipetted onto the strips and allowed to wick through the fibrin. The distance the blue dye wicks through the strip correlates precisely to the fibrinogen concentration. The diagnostic can provide results within a minute. It can distinguish low fibrinogen concentrations (ie. <2 g/L) from normal fibrinogen concentrations. It shows remarkable reproducibility between healthy individuals. It is unaffected by common blood conditions such as acidosis, blood alcohol, severe hypertriglyceridemia, severe haemolysis and warfarin administration. Finally, it is unaffected by humidity and can withstand cold temperatures. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:72 / 83
页数:12
相关论文
共 68 条
[1]  
Aldrich S., 2017, THROMBIN HUMAN PLASM
[2]   Rapid paper diagnostic for plasma fibrinogen concentration [J].
Bialkower, Marek ;
McLiesh, Heather ;
Manderson, Clare A. ;
Tabor, Rico F. ;
Garnier, Gil .
ANALYST, 2019, 144 (16) :4848-4857
[3]   Transfusion and coagulation management in major obstetric hemorrhage [J].
Butwick, Alexander J. ;
Goodnough, Lawrence T. .
CURRENT OPINION IN ANESTHESIOLOGY, 2015, 28 (03) :275-284
[4]   Low molecular weight heparin inhibits plasma thrombin generation via direct targeting of factor IXa: contribution of the serpin-independent mechanism [J].
Buyue, Y. ;
Misenheimer, T. M. ;
Sheehan, J. P. .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2012, 10 (10) :2086-2098
[5]  
Castellucci L.A., 2015, AM SOC HEMATOL
[6]   LAMBDA-LAMBDA CROSS-LINKING SITES IN HUMAN AND BOVINE FIBRIN [J].
CHEN, R ;
DOOLITTLE, RF .
BIOCHEMISTRY, 1971, 10 (24) :4486-+
[7]   INACCURACY OF THE DERIVED FIBRINOGEN MEASUREMENT [J].
CHITOLIE, A ;
MACKIE, IJ ;
GRANT, D ;
HAMILTON, JL ;
MACHIN, SM .
BLOOD COAGULATION & FIBRINOLYSIS, 1994, 5 (06) :955-957
[8]  
Cleland Stuart, 2016, World J Transplant, V6, P291, DOI 10.5500/wjt.v6.i2.291
[9]   Management of coagulopathy associated with postpartum hemorrhage: guidance from the SSC of the ISTH [J].
Collins, P. ;
Abdul-Kadir, R. ;
Thachil, J. .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2016, 14 (01) :205-210
[10]   Epidemiology of urban trauma deaths: A comprehensive reassessment 10 years later [J].
Cothren, C. Clay ;
Moore, Ernest E. ;
Hedegaard, Holly B. ;
Meng, Katy .
WORLD JOURNAL OF SURGERY, 2007, 31 (07) :1507-1511